GEM II Battery Powered Ring Cutter Kit

www.aztecmedical.co.uk
2
Operational Guide
1. SelectandmountappropriatecungdiscforGEMIIringcuer.Move
‘lockingswitch’tolockposion.Insertcorrectlyloadedbaerycasseein
toGEMIIbody.
2.Applyagenerousquantyofwaterbasedgeltoringsurface.
3. Slidengerguardunderring.
4. InsertGEMIIguidearmdiscintongerguardguideblock.Restcungdisc
onringsurface.AcvatemotorallowingtheweightoftheGEMIIcung
headalonetoprovidethenecessarydownwardpressureontothecung
disc.
5. MoveGEMIIbackandforthalongguideblocksothatcung
disctraversestheenrewidthofthering.Asuddenincrease
inrotaonspeedindicatesringhasbeencutthrough.
6. Ifpaentwarnsofheatbuild-upstopcungimmediately,
cleangelfromringsurfaceandre-applyfreshgelandconnue
withcungprocess.
7. UseGEMIIringspreaderpliersorforcepstoremovering.
Foramoredetaileddemonstraonofthe
cungprocesswatchthe
GEMIIBaeryPoweredRingCuerDVD

www.aztecmedical.co.uk
3
Safety Instructions
Maintenance Instructions
READ INSTRUCTIONS BEFORE USE
Light eye protecon should be worn by operator and paent.
• NeveruseringcuerwithoutngerguardorPerspexshieldinplaceorifeithercomponentis
damaged.
• NeveruseanypowersourceotherthandomescAAsizebaeriescapableofdeliveringa
maximumvoltageof6vDC.
• Nevermodifytheringcuertorunonmainspower.
• NeverexaminearotangcungdiscexceptthroughthePerspexshield.
• Neverreusedamagedorbadlyworndiscs.
• Never start cung through a ring without rst applying a signicant quanty of water based
gel to the ring surface. The gel acts as a heat sink, traps cut ring debris and impedes
trajectory of parcles from a rotang disc.
• Neveroperatetheringcuerinanatmospherewhereasparkcouldcauseanexplosion.
• Neveruseorre-useacungdiscifeitheroneorbothplascwasherssupporngthediscare
missing.
• Alwaysengagethe“Lock”immobiliserswitchtodeacvatethemotorwhen:
a) Mounngordisconnecngacungdisc.
b) Engagingthengerguard.
c) Pausingduringcungtoexaminethecungprogress.
d) Wipingawayusedgelandreapplyingfreshgel.
e) Whenringcuerisnotbeingacvelyusedorleunaendedwhenstored.
Always:
• Examinecungdiscspriortouse.Discardanydamagedorbadlyworndiscs.
• Restthecungbladeontheringsurfacebeforeacvangthemotor.
• Warn the paent that the cung process generates heat and that the paent should warn
the operator if the heat build-up is causing discomfort. If this happens the cung process
must stop. The water based gel wiped from the ring surface and fresh cold gel reapplied
before re-starng the cung process.
• Cleanngerguardunitaeruse.
• RemovebaeryholderfromGEMbodyaeruse.
• Stop motor aer 10 minutes of connuous use and allow motor to cool down for 15 minutes
before re-starng.

www.aztecmedical.co.uk
4
Maintenance Instructions
The ring cuer may be wiped down with any decontaminaon soluon but must not be soaked
in uid or autoclaved.
DISC CARE
Removedisc(RETAINLOCKINGSCREW).Examinediscfordamageorexcessivewear-ifthisisthe
case,replacedisc.
FINGER GUARD CARE
Cleanupngerguardandguidechannelofngerguard.Examinemetalguard;makesuredisc
hasn’tcutthrough.Ifsoreplacemetalguard.
PERSPEX SHIELD CARE
WipeanyresiduefromPerspexshield.
Aer use, examinaon and cleaning, always return the GEM II Ring Cuer and its components
back to their alloed spaces in the GEM II presentaon case.

www.aztecmedical.co.uk
5
Technical Specications
Declaration of Conformity
Model A-Z 300 Series 101
MotorRe280/3DryBearingWeight:
HandPieceWeight:
PowerSource:
NoLoadSpeed:
Torque:
StallTorque:
SoundPressure:
SoundPower:
VibraonLevels:
44gms
127gms
6voltDC(4xAA)Baeries
3v8,800rpm
6v16,000rpm
3v63gcm
6v120gcm
3v126gcm
6v240gcm
61.08dB(A)
73.58dB(A)
3.2m/s2
Recycling & Disposal

www.aztecmedical.co.uk
6
Declaration of Conformity
THE DECLARATION OF CONFORMITY
Wedeclareunderoursoleresponsibilitythatthisproductisinconformitywiththefollowingstan-
dardsorstandardiseddocuments.EN55014inaccordancewithDirecves2004/108/EC,2006/42/
ECandEN60745
ChristopherMacGregor
HeadofQualityAssurance
WEEE compliant registraon no. WEEE/DG 3326 WV
Recycling & Disposal
Onlydisposeofelectrical/electronic/baeryitemsinseparatecolleconschemes,whichcaterfor
therecoveryandrecyclingofmaterialscontainedwithin.
Yourcooperaonisvitaltoensurethesuccessoftheseschemesandfortheproteconofthe
environment.

www.aztecmedical.co.uk
7
Guarantee
DearCustomer,
Intheunlikelyeventthatyourdevicedevelopsafault,pleasecontactourcustomerservice
department.
1. Theseguaranteetermscoveraddionalguaranteerightsanddonotaectyourstatutory
warrantyrights.
2. Ourguaranteecoversproblemscausedbymaterialormanufacturingdefects,andwillresultin
therepairofthesedefectsorreplacementofthedevice.
3. Thefollowingarealsoexcludedfromourguarantee:
a) Faultsduetoaccidents,customermisuse,orunauthorisedrepairs.
b) Consumablepartssuchasblades.
c) Failureduetolackofrounemaintenance.
d) Failureasaresultofnotusingtheequipmentinaccordancewiththemanualandsafety
instrucons.
e) Anyunauthorisedmodicaonstothedeviceoritscomponents.
4. Theguaranteeisvalidforaperiodof2yearsstarngfromthepurchasedateofthedevice.
Guaranteeclaimsshouldbesubmiedbeforetheendoftheguaranteeperiodwithintwo
weeksofthedefectbeingnoced.Noguaranteeclaimswillbeacceptedaertheendofthe
guaranteeperiod.Theoriginalguaranteeperiodremainsapplicabletothedeviceevenif
repairsarecarriedoutorpartsarereplaced.Insuchcases,theworkperformedorpartsed
willnotresultinanextensionoftheguaranteeperiod,andnonewguaranteewillbecome
acvefortheworkperformedorpartsed.
A-Z Tec Medical Ltd
Email:inf[email protected]o.uk
www.aztecmedical.co.uk

www.aztecmedical.co.uk
8
Guarantee
Trouble Shooting & F.A.Q’s
TROUBLE SHOOTING
Motorfailstooperate
Motorstallsduringcung
Cungdiscmakeslileprogressincung
throughring
Check baeries are loaded into the baery
cassee correctly.
Check that retaining springs in baery cas-
see are sound and holding baeries rmly
in place.
Check baeries are in a charged condion.
Check that ‘Lock’ switch on GEM II unit is
not engaged.
Operator applying excessive force during
cung process.
Baeries are depleted, change for fully
charged baeries.
Wrong disc selected for ring metal type
• UseDiamondcungdisc
(Ref.A-Z223)forhardmetalsi.e.
Iron,Steel,Planum.
• UseCarbidecungdisc
(Ref.A-Z224)forsometalsi.e.
Gold,Silver,Copper.
Disc is badly worn, change for new disc
Diamondcungdisc(Ref.A-Z223)
Tocheckifdiscisworn,runngeraround
cungdiscedge.Ifsmoothtotouchthe
diamondgritiswornaway,replacedisc.

www.aztecmedical.co.uk
9
Cungdiscmakeslileprogressincung
throughring(Connued)
Lockingscrewunwindsduringoperaon
Carbidecungdisc(Ref.A-Z224)
Ifcungdiscisworndowntoplasc
spacers,replacedisc.
Baeries have been loaded into baery
cassee incorrectly. Re-load baeries into
cassee in the correct order and make sure
the arrows on the baery cassee and the
GEM II unit are aligned.
F.A.Q’s
1. Howmanyringswillacungdisccut
through?
2. Whyisitnecessarywhencungthrough
hardmetalstomakeacuthalfway
throughtheringononesideandthen
allthewaythroughinaposiondirectly
oppositetherstcut?
A carbide disc acng on a so metal, i.e.
Gold wedding ring approximately 4mm
wide by 1mm thick will cut through 10-15
rings.
A diamond disc acng on a hard metal, i.e.
steel 4mm wide by 1mm thick would be
capable of cung through approximately 6
rings allowing for the fact that a hard metal
requires cung in 2 separate locaons on
the ring.
N.B. The cung surface of the ring must be kept as cool as pos-
sible to preserve the diamond grit on the cung edge of the disc.
This is achieved by cung for 3 or 4 seconds, pausing for a second
and repeang the process.
Rings made of hard metals when cut
through tend to close up trapping the
cung disc. This is due to the high tensile
strength in the metal. Parally cung
through a ring signicantly reduces the ten-
sion in the ring so that when the ring is cut
through on the opposing side to the rst cut
the ring won’t collapse in on itself and trap
the cung disc.