az-instrument 88128 Manual de usuario

OPERATION MANUAL
TEMPERATURE / HUMIDITY
DATA LOGGER
Model: 88128 8828 8829
8813 8814 8815
8833 8834 8835
Interface

Material supplied.......................................................................
Group Files...............................................................................
Previous setting,Temperature Chart,Cursor status...................
Introduction...............................................................................
Features....................................................................................
Front View ................................................................................
LCD display (Model 8828 / 8829).......................................................
Battery replacement..................................................................
Software Installation .................................................................
Main screen & introduction.......................................................
Retrieve File..............................................................................
Save File...................................................................................
Comport Setup..........................................................................
Logger setting...........................................................................
A) Sample point setup............................................................................
B) Sample rate........................................................................................
C) Start mode set up...............................................................................
D) Logger's clock setting.........................................................................
E) Alarm setting......................................................................................
F) Unit setting ,Logger ID setting............................................................
G) Sleep Mode setting & Data Table......................................................
Data Table : Edit (Go to ,Find ).................................................
Statistics....................................................................................
Print Graph................................................................................
Blank logo,Message..................................................................
Download commands................................................................
Display control..........................................................................
General Specification................................................................
F.A.Q. Warranty and Return Authorization................................
INDEX
1
2
3
4
5
6
7
8-10
11-12
13
14
15
15
16
16
17
18
19
20
21-24
25-27
28
29-30
31
32
33
34-37
38-41
42
Index

Thank you for purchasing this Temperature Data Logger! This unit
has been developed to meet your maximum satisfaction with its
user-friendly design. Review the entire manual for a complete
overview of the operation of this new data logger.
You may review the manual from Autoplay Menu, double click
"Run software, Manual (PDF)"and peruse every procedure
and function step by step. The logger is very easy-to-use.
The software is used to readout the stored data and see as a graph,
showing the history with real-time clock, the tabular data can be
viewed or exported to a spreadsheet for various analysis.
One interface can be used with multiple loggers, designed as a
saving cost unit. There are 3 color of interfaces for choice: White
,Dark Blue, Burgundy.
IDEAL FOR APPLICATION:
Monitoring Ambient condition in Greenhouses, Warehouses,
Food transport, Aircraft cabins, refrigerate truck,
containers, railway ....Art galleries and
Museum, incubation process,
Hatcheries, HVAC field
(Heat, Ventilation, Air
Conditioning),
collecting data
for QC.....
INTRODUCTION
1

MATERIAL SUPPLIED
Check for damaged or missing parts in your data logger before
starting:
The Data Logger Set should contain:
2. Either one of the following :
Model: 88128, 8828, 8829, 8813, 8814, 8815, 8833, 8834, 8835
The Data Loggers, supplied with one CR2 /ER3(3.6V lithium
battery) or CR2032 (3.0 V button cell)
Model: 8818P(White) , 8828P(Dark blue), 8829P (Burgundy)
The RS232 Interface with cable & software.
Model: 8824P(White)
The USB Interface with cable & software.
Model: 88128S, 8828S, 8829S, 8813S,8814S,8815S,8833S,
8834S,8835S
The complete set including data logger with battery ,
interface and software.
1
3
88888
88888
H/M/S
2
88128/8828/8829
88128S/8828S/8829S
8818P/8828P/8829P
AZ
8829
T.RH%LOGGER
%RH:0~100%
Temp.o
:-40~85C
ALMREC
AZ
8829
T.RH%LOGGER
%RH:0~100%
Temp. o
:-40~85C
ALMREC
2
Before starting thelogger setting ,pleaseread throughly the
whole operation manual,there are someFAQ listedin some
pages for troubleshootingreference.
1. Operation manual
Example:

FEATURES
Up to 4000 (8813,8814) or 8000 (8815,8833,8834) or 16000 (88128,
8828,8829,8835) sample readings with real-time clock memory.
LCD display of data ( 8828, 8829, 8814, 8815, 8834, 8835).
Programmable sample interval from 1 second to 12 hours.
oo
Temperature unit: C / F selectable.
User-defined High / Low limit alarm.
Built-in real-time clock.
Up to 5 different start modes, please see summary in page 17.
Programming with RS-232 and USB interface.
Data retained when battery is low or has been removed.
IP65 waterproof housing design.
Hanger at the rear upper for hanging on the wall to prevent
losing or falling down .
One Interface can be used with several loggers to save cost.
Download data to other program for further analysis.
All data is saved in text format and can be easily transformed
into Microsoft Office applications.
Easy to use Software provides :Retrieve file, Save file, Logger
setting, Comport setting, Group file, Print graph, Data table
list, Statistic .......
Sleep mode and Non-Sleep mode to be selectable to display
current Temperature and Humidity (LCD models)
3
R
Additional start/stop key to power on/off the LCD display and start/
stop the logging. (8813/14/15, 8833/34/35)
External temperature probe socket included in 8833~8835 enables
to measure second channel temperature.

FRONT VIEW
-Stands for RECORD
For model without LCD : 88128, 8813,8833
"REC" is flashing while logging the temperature records. Yellow LED
will stop flashing after complete recorded or battery is out of power.
REC yellow light flash
5 second, the LED flash every 5 seconds.
For model with LCD : 8828, 8829, 8814, 8815, 8834, 8835
Both yellow LED light and "REC" indicator will active and display on the
screen per every set sample interval. F
"ALM" is flashing while recorded value is higher than set HI or
less than LO setting, the logger alarm designed as not audible,
but only for reminding or warning the user to do necessary action.
REC
per sample rate setting. For 88128, if
the interval is over
or 8828/8829, if the interval is
over 5 second, the LED flash every 5 seconds
For model without LCD : 88128, 8813, 8833
"ALM" "ALM" LED will stop flashing after downloading to a PC or
battery is out of power. "RED" light flash per sample rate setting.
For 88128, if the interval is over 5 second, the LED flash every
5 seconds.
For model with LCD : 8828, 8829, 8814, 8815, 8834, 8835
Both red LED light and "ALM" indicator will active and display on the
screen per every set sample interval. For 8828/8829, if the interval is
over 5 second, the LED flash every 5 seconds
4
- Stands for ALARMALM

LCD DISPLAY
5
REC -"REC" is displayed while logging the temperature
or humidity. When stop logging and only in monitoring mode,
If the logger is in Non-sleep mode, "REC" will not appear on
LCD.
HI -"HI" is displayed and alarm LED is flashing if a
temperature/or humidity is higher than set High value
in the logger unit .
LOW - "LOW" or "LO" is displayed while logged temperature is lower
than set Low value in the logger unit .
RH% -Display Relative Humidity %.(Though you might have
seen RH% when replacing with a new battery , which
is not available for the model 8828 but model 8829
Temperature/ Humidity datalogger .)
oC -Temperature displays reading in Celsius
oF-Temperature displays reading in Fahrenheit
COMM - When communicating with computer ,"COMM" or "COM" is
shown at the top of the screen.
- External probe temperature. In 8835, the air temperature,
RH% and external probe temperature will appear in turns.
EX
REC
HI
LOW
COMM
RH%
oC
oF
Model: 8828, 8829,8814,8815 Model: 8834, 8835
REC
HI
LO
COM
RH%
O
EX BAT

BATTERY REPLACEMENT
The dataloggers are designed with a waterproof housing and allow
the user to replace battery when it has expired .You will see "Lo" or
"BAT" appeared on the display when battery is weak.
Follow the steps to remove and replace battery:
1. Unscrew the datalogger from the rear side .
2. Do not remove o-ring and make sure the o-ring is in its place
(groove).
3. Remove the expired battery
4. Insert a new battery CR3/ ER2 or CR2032, make sure the battery is
inserted with correct polarity.
5. Re-screw the rear cover with screwdriver .
+CR2/ER3-
Model:
88128/8828/8829
CR2032
Model:
8813/8814/8815
Model:
8833/8834/8835
6
+CR2/ER3-

Installation procedure :
1. Slide the logger unit onto the RS232 or USB interface.
2. Connect the socket of the interface to COM1...COM8 of computer.
3. Insert the CD-ROM to the computer for starting software set up:
a).Install Software. To install the program.
b).Manual (PDF)
c
Open the PDF format manual.
).Web Site. Visit our web site in your browser.
d) .Brow CD-ROM. Browse the CD-Rom using Windows.
E) .Exit. Exit the software.
Microsoft Office is a registered
trademark of Microsoft Corporation.
R
SOFTWARE INSTALLATION
7
3.4
AZ8813~8815
AZ8833~8835

The data logger program is easy to operate from its main screen.
8
Keyboard Actions for Cursor
Make sure you have selected a cursor, when you click the red vertical
line, it turns bold red line, the same for green line. You will see the
numbers at the left lower part (cursor status) changed while pressing
arrow left or down arrow key for last record or pressing right or up
arrow key for next record.
MAIN SCREEN
Diagram A: Main Screen
LOGO
Display Control
Download
Commands
Cursor 1
(red)
Cursor 2
(green)
Previous
Setting
Temperature
Chart
Humidity
Chart
Cursor
Status
Message Record Number
Time
Retrieve File Save
File
Com. Set
Logger
Set
Data
Table
Statistics
Print
Graph
Group
Files
Logo
Help
Help
Este manual sirve para los siguientes modelos
8
Tabla de contenidos