Avtech Room Alert 32S Manual de usuario

User’s Guide & Reference Manual
AVTECH Software, Inc. Temperature & Environment Monitoring... Made Easy! AVTECH.com
Room Alert 32S
AVTECH
Room Alert®32S
Temperature & Environment Monitoring... Made Easy!

Copyright Information
© Copyright 1988-2020 AVTECH Software Inc.
All Rights Reserved. No part of this book may be used or reproduced for commercial benet in any form or by any
means, or stored in a database or retrieval system, without prior written permission of AVTECH Software Inc.,
except in the case of brief quotations embodied in articles and reviews. Making copies of any part of this book for
any purpose other than your individual use is a violation of United States copyright laws and international treaty
provisions. For information or additional copies, contact AVTECH Software Inc., as directed below. Published in the
United States of America.
Warning and Disclaimer
This publication is shipped as is, without warranty of any kind, either express or implied. While every precaution
has been taken in the preparation of this publication, the publisher and authors assume no responsibility for errors
or omissions. Neither is any liability assumed for damages resulting from the use of the information or instructions
contained herein. It is further stated that the publisher and authors are not responsible for any damage or loss to your
data or equipment that may result directly or indirectly from your use of this publication and the related hardware &
software. Nothing on any AVTECH website or in documentation shall be construed as conferring any license under any
of the AVTECH Software (AVTECH) or any third party’s intellectual property rights, whether by estoppel, implication, or
otherwise.
Trademark Acknowledgements
AlertScript, AVTECH, the AVTECH Logo, AVTECH Software, the AVTECH System Manager Character, AVTECH.com,
AVTECHSoftware.com, Environment Alarm, “Environment Monitoring Made Easy!”, EnvironmentMonitor.com, “IT
Environment Monitoring Made Easy!”, MUPS, Device Discovery, Device ManageR, “Protect Your Facility... Don’t Wait
Until It’s Too Late!”, “Protect Your IT Environment... Don’t Wait Until It’s Too Late!”, Room Alert, Room Alert Signal
Tower, Signal Tower, RoomAlert.com, RoomAlert.co.uk, RoomAlert.eu, TemPageR, TemPageR.com and “Temperature
Monitoring Made Easy!”, WiSH, and WiSPR, are trademarks or registered trademarks of AVTECH Software Inc. Any
other trademarks, product or company names mentioned herein are the property of their respective owners and used
strictly for the purpose of identifying compatibility. AVTECH Software Inc. cannot attest to the accuracy of any other
organization’s ownership claim to a trademark and use of any trademark in this publication should not be regarded as
aecting the validity of any trademark or service mark.
Contact Us
Worldwide Headquarters
AVTECH Software, Inc.
16 Cutler Street, Cutler Mill
Warren, RI 02885-2761 USA
Visit us on the web at AVTECH.com
Log in to your account at RoomAlert.com
Sales
Need to expand your monitoring capacity? Visit our online store 24/7 at https://AVTECH.com/Products/
Environment_Monitors/
Want expert advice? Contact our Product Specialists Monday to Friday, 9 AM to 5 PM EST (excluding holidays).
Quote Request at https://AVTECH.com/quote/
Live Sales Chat at https://AVTECH.com/
888-220-6700 (In the USA & Canada, toll-free)
401-628-1600 (Outside the USA & Canada)
Technical Support
Questions about your product? Get answers 24/7 at our online Support Center.
Need more help? Contact our Technical Support Specialists Monday to Friday, 9 AM to 5 PM EST (excluding
holidays).
Live Support Chat at https://AVTECH.com/support/
888-220-6700 (In the USA & Canada, toll-free)
401-628-1600 (Outside the USA & Canada)
AVT-200327-1.0.0

AVTECH Software, Inc. Page 2 AVTECH.com
Room Alert 32S (RA32S-DAP-RAS)
Table of Contents
Room Alert 32S Package Contents ............................................................. 3
The Room Alert 32S ID Box .................................................................. 3
Front ............................................................................................. 3
Back.............................................................................................. 3
How To Install Your Room Alert 32S ........................................................... 6
Step 1: Connect Your Room Alert 32S Hardware ..................................... 6
A. If Your Network Is Power Over Ethernet (PoE) Enabled ..................... 6
B. If Your Network Is Not Power Over Ethernet (PoE) Enabled ............... 6
Step 2: Connect External Sensors And Other Compatible Components........ 6
How To Use Your Room Alert 32S Web Interface .......................................... 7
Status................................................................................................ 7
Banner & Header............................................................................. 8
Sensor Display Area ........................................................................ 9
Settings ........................................................................................... 11
Sensors ....................................................................................... 13
Alarms......................................................................................... 20
Network....................................................................................... 23
Email........................................................................................... 25
SNMP .......................................................................................... 28
Security ....................................................................................... 31
Advanced ..................................................................................... 32
For More Information ............................................................................. 35
AVT-200325-1.0.0

AVTECH Software, Inc. Page 3 AVTECH.com
Room Alert 32S (RA32S-DAP-RAS)
Room Alert 32S Hardware
Front
92510 6
Power
Port
Internal Sensors
• Temperature
• Humidity
• Power
• Battery Back-up
Back
Battery
Back-up
On / O
Button
Switch
Sensor
Ports
(16)
Reset
Button
Relay
Output
Ports
(2)
8711
31
4
Power
LED
Digital
Sensor
Ports
(8)
Ethernet
Port
Alarm
LEDs
Light Tower &
Relay Adapter
Ports
(2)
Analog
Input
Ports
(2)
(PoE enabled)

AVTECH Software, Inc. Page 4 AVTECH.com
Room Alert 32S (RA32S-DAP-RAS)
Internal Temperature Sensor
An internal digital sensor monitors ambient
temperature with a range of -40° to 185° F (-40°
to 85° C).
Internal Humidity Sensor An internal digital sensor monitors relative
humidity with a range of 5% to 95% RH.
Internal Power Sensor An internal sensor monitors the power state (main
power or battery-back up power).
Internal Battery Back-up An internal battery back-up can power Room Alert
32S for up to 15 minutes.
Power Port
A standard power port connects Room Alert to an
electrical outlet with any AVTECH 5V 1A Power
Adapter. Models are available for all countries.
Ethernet Port An RJ-45 port connects Room Alert to your network
via an RJ-45 Ethernet cable.
Reset Button A small push button resets Room Alert to factory
default settings. (Please push softly.)
Switch Sensor Ports
Dry contacts connect Room Alert to any AVTECH
switch sensor or dry contact on a device (e.g.,
HVAC, generator, pump, fan, etc.) via standard
speaker wire or low-voltage 2-wire cable.
Digital Ports
Standard RJ-11 jacks connects any AVTECH digital
sensor to Room Alert via a standard RJ-11 (straight
through) telephone cord.
Light Tower & Relay Adapter Ports
A standard RJ-11 jack connects a Light Tower &
Relay Adapter to Room Alert via a standard RJ11
(straight through) telephone cord.
Analog Input Ports
Sets of contacts connect any low-voltage analog
sensor to your Room Alert via standard speaker
wire.
Relay Output Ports Sets of contacts connect any low-voltage device to
your Room Alert via standard speaker wire.
Power Status LED
An LED indicates the power status of Room Alert
32S (Green = Main or PoE, Red = Internal UPS
power).
Alarm LEDs
LEDs light red or green to indicate alarm or clear
status of Digital or Switch sensors (Green = Clear,
Red = Alarm).
Battery Back-up On / O Button A push button turns the Room Alert’s internal
battery back-up on and o.
1
2
3
4
5
6
7
8
9
10
11
Room Alert 32S Hardware Features

AVTECH Software, Inc. Page 5 AVTECH.com
Room Alert 32S (RA32S-DAP-RAS)
Standard Room Alert 32S Package
The standard package includes:
• One (1) Room Alert 32S ID Box
• One (1) External Digital Active Power Sensor
• One (1) AVTECH 5V 1A Power Adapter
• One (1) Ethernet Cable (10’)
AVT-200325-1.0.0

AVTECH Software, Inc. Page 6 AVTECH.com
Room Alert 32S (RA32S-DAP-RAS)
How To Install Your Room Alert 32S
Connect Your Room Alert Hardware
If Your Network Is Power Over Ethernet (PoE) Enabled
• Connect one end of a standard Ethernet cable to
the Room Alert’s Ethernet port.
• Connect the other end to a PoE-enabled network
jack.
That’s it! Your Room Alert is now powered and
discoverable on your network.
If Your Network Is Not Power Over Ethernet (PoE) Enabled
A. Connect To Your Network First
• Connect one end of a standard Ethernet cable to the Room Alert Ethernet port.
• Connect the other end to a network jack.
B. Then Connect To A Power Source
• Plug one end of AVTECH’s 5V 1A Power Adapter into the Room
Alert power port.
• Plug the other end into a surge-protected power source.
Your Room Alert is now powered and discoverable on your network!
NOTE
Connect Included External Sensors And Other Compatible Components
Please install included external sensors and any other compatible components you may have
purchased according to their Installation Notes, available at AVTECH.com.
Use only AVTECH’s 5V 1A Power Adapter. Other voltages could damage the
Room Alert hardware and void your warranty. If you don’t have an AVTECH
5V 1A Power Adapter, please visit our online store at AVTECH.com
to acquire one. Models are available for all countries.
AVT-200325-1.0.0

AVTECH Software, Inc. Page 7 AVTECH.com
Room Alert 32S (RA32S-DAP-RAS)
How To Use Room Alert’s Web Interface
You may congure your Room Alert through its built-in web interface. To access the interface,
you may either:
• Type the IP address of your Room Alert monitor directly into the address bar of your
web browser.
• Discover your Room Alert monitor with Room Alert Link software, and select its IP
address from the Monitors list.
• Select your Room Alert monitor in your RoomAlert.com account and click the
Device Interface button.
Your Room Alert’s web interface has 3 tabs:
• Status
• Settings
• Help
Status
To view your Room Alert’s current sensor status, select Status in the navigation bar to the
left of your screen.

AVTECH Software, Inc. Page 8 AVTECH.com
Room Alert 32S (RA32S-DAP-RAS)
Banner & Header
Banner
At the top of the page runs the red Room Alert banner.
• You may visit AVTECH.com by selecting the AVTECH logo in the banner.
Header
Below the banner is the header, where you may view basic information about your device.
On the left side of the header, you may nd the following information:
• Device Name
• Model
• MAC Address
• Serial Number
• Firmware Version
• Local IP Address
• Power Status
On the right side of the header, you may nd the following information under Account Status:
• The account your Room Alert monitor is registered to in RoomAlert.com.
• Your RoomAlert.com account level.
• Whether push to RoomAlert.com is enabled.
• Whether the Room Alert monitor is connected to your RoomAlert.com account.
• The time & date the Room Alert monitor last pushed sensor data to your
RoomAlert.com account.

AVTECH Software, Inc. Page 9 AVTECH.com
Room Alert 32S (RA32S-DAP-RAS)
Sensor Display Area
In the main viewing pane of the Status tab is the sensor display area. Here you may view
your sensor data and temporarily change Status page settings.
Temporary Status Page Settings
You may temporarily change the refresh interval of the Status page and default temperature
scale here.
• To temporarily modify the refresh interval of the Status screen, which is 5 seconds
by default, you may enter a value in seconds in the Refresh this page every X
seconds eld. Click outside the eld to temporarily commit the change.
• To temporarily toggle the temperature scale between Fahrenheit (F) and Celsius
(C), select Fahrenheit or Celsius.
Tip
Alarm Status Icons
Status icons are displayed for sensors that have thresholds set:
Green circle with “” mark........Sensor is in a clear state.
Red circle with “X” mark ...........Sensor is in an alarm state.
No status icon.........................Sensor has no thresholds set.
Refer to the Advanced section in this manual for instructions on setting the
default status page refresh rate and temperature scale for Room Alert.
Tabla de contenidos
Otros manuales de Sistema de seguridad de Avtech
Manuales populares de Sistema de seguridad de otras marcas

EDM
EDM Solution 6+6 Wireless-AE Manual de usuario

Highway Safety Group
Highway Safety Group EA401 Manual de usuario

Siren
Siren LED GSM Manual de usuario

Detection Systems
Detection Systems 7090i Instrucciones de montaje

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manual de usuario

Siemens
Siemens FDM273 Manual de usuario















