AVICHE AH-C10 Manual de usuario

Medical Compressor Nebulizer
Version 1.0
Thank you for choosing AVICHE Medical Compressor Nebulizer. Please read this User
Manual carefully before use and maintenance and keep it properly for future reference.
Model: AH-C10
User Manual


1
The illustrations shown in this user manual are image drawings and
may differ slightly from the appearance of the actual product.
Table of Contents
Before Using the Device
Introduction
Intended Use
Safety Information
Know Your Unit
Operating Instructions
Preparing the Nebulizer for Use
Attaching the Air Tube
Using the Device
Care and Maintenance
Cleaning after Each Use
Daily Disinfecting
Changing the Air Filter
Caring for the Device
Troubleshooting
Troubleshooting Guide
Limited Warranty
FCC Statement
Specifications
Guidance and Manufacturer's Declaration
After-sales Service and Warranty Card
…………………………………
…………………………………………………
………………………………………………
………………………………………
……………………………………………
……………………………………
……………………
…………………………………
…………………………………………
……………………………………
………………………………
…………………………………………
…………………………………
……………………………………
……………………………………………
…………………………………
…………………………………………
……………………………………………
………………………………………………
………
……………
2
2
2
3
8
10
10
12
13
16
16
17
18
19
20
20
21
22
23
24
31

2
Introduction
Before Using the Device
Thank you for purchasing the AH-C10 Medical Compressor Nebulizer.
This product was developed for the successful treatment of asthma, allergies
and other respiratory disorders. The compressor forces air to the nebulizer.
When the air enters the nebulizer, it converts the prescribed medication into
an aerosol of microscopic droplets that can easily be inhaled.
Your AH-C10 Medical Compressor Nebulizer comes with the following
components:
·Compressor (Main Unit)
·Nebulizer Kit
·Air Tube (PVC, 150 cm)
·Air Filters (Package of 2)
·User Manual
·Adult or Child Mask (PVC)
For specific information about your own nebulizer,
CONSULT YOUR DOCTOR.
SAVE THESE INSTRUCTIONS
Intended Use
The AH-C10 Medical Compressor Nebulizer is intended to provide air to the
pneumatic nebulizer in order to aerosolize medications for inhalation by the
patient for respiratory disorders. The system is designed for use with
pediatric (defined by the prescribed medication) and adult patients in the
home, hospital, and sub-acute settings.
All warnings and cautions described in this manual should be observed.

3
Safety Information
To ensure the correct use of the product, basic safety measures should
always be followed including the warnings and cautions listed in this user
manual.
Operating the Device
For type, dose, and regime of medication follow the instructions of your
physician or licensed healthcare practitioner.
If you feel anything unusual during use, stop using the device immediately
and consult your physician.
Do not cover the compressor with a blanket, towel, or any other type of
cover during use. This could result in the compressor overheating or
malfunctioning.
Do not use the device where the device may be exposed to flammable
gas or vapors.
Do not use tap or mineral water in the nebulizer for inhaling purposes.
Clean and disinfect the nebulizer kit, mouthpiece, and optional nosepiece
or optional masks before using them for the first time after purchase.
If the device has not been used for a long period of time, clean and
disinfect the nebulizer kit, mouthpiece, and optional nosepiece or optional
masks before using them.
SAFETY SYMBOLS USED IN THIS USER MANUAL
WARNING
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury to the user
or patient or damage to the equipment or other property.

4
Pentamidine is not an approved medication for use with this device.
Always dispose of any remaining medication in the medication cup after
each use. Use fresh medication each time you use the device.
Do not leave the device or its parts where it will be exposed to extreme
temperatures or changes in humidity, such as leaving the device in a
vehicle during warm or hot months, or where it will be exposed to direct
sunlight.
Do not use or store the device where it may be exposed to noxious fumes
or volatile substances.
Make sure that the nebulizer kit is clean before use.
Do not use in anaesthetic or ventilator breathing circuits.
Not suitable for use in the presence of flammable anesthetic mixture with
air or oxygen or nitrous oxide.
Do not operate where oxygen is being administered in a closed
environment (such as an oxygen tent).
Provide close supervision when this device is used by, on, or near infants,
children or compromised individuals.
If the device is used continuously, the service life of the device may be
shortened.
Limit use to 30 minutes at a time, and allow a 30 minutes interval before
using the device again.
When using the device, the main unit may become hot.
Do not touch the main unit for other than necessary operation such as
turning off the power while nebulizing.
Do not insert any object into the compressor.

5
Make sure the air filter is clean. If the air filter has changed color or has
been used on average for more than 60 days, replace it with a new one.
Make sure the nebulizer kit is correctly assembled, the air filter is properly
installed, and the air tube is correctly connected to the compressor and
the nebulizer kit. Air may leak from the air tube during use if not securely
connected.
Inspect the compressor (main unit) and the nebulizer parts each time
before using nebulizer kit. Make sure no parts are damaged, the nozzle
and air tube are not blocked and the compressor operates normally.
Do not use the device if the air tube is bent.
Do not block the air filter cover.
Do not alter the baffle, the nozzle in the medication cup or any part of the
nebulizer kit.
Do not add more than 8mL of medication to the medication cup.
Do not operate the device at temperatures greater than +40˚C (+104˚F).
Do not tilt the nebulizer kit so the angle of the kit is greater than 45˚.
Medication may flow into the mouth.
Do not shake the nebulizer kit while using the device.
Do not subject the compressor or any of the components to strong
shocks, such as dropping on the floor.
This device is approved for human use only.
Do not disassemble or attempt to repair the device or components.
Operate the device only as intended. Do not use the device for any other
purpose.

6
Dispose of the device, components and optional accessories according to
applicable local regulations. Unlawful disposal may cause environmental
pollution.
Use only AVICHE authorized parts and accessories. Parts and
accessories not approved for use with the device do not perform the
expected specification or it may damage the unit.
Changes or modification not approved by AVICHE will void the user
warranty.
To avoid injury to the nose mucosa, do not squeeze the optional
nosepiece into the back of the nose.
To avoid the medication residue on the face. After nebulization, be sure to
wipe the face after removing the optional masks.
When using this device, there will be some noise and vibration caused by
the pump in the compressor. There will also be some noise caused by the
emission of compressed air from the nebulizer kit. This is normal and
does not indicate a malfunction.
When sterilizing parts by boiling, make sure that the container does not
boil dry.
Do not use the device while sleeping or if drowsy.
Do not block the slit between the cap and the inhalation air inlet.
Do not connect the power cord terminal using wire or other metallic
conductors.
Do not use the compressor (main unit) or power cord while they are wet.
Do not plug or unplug the power cord into the electrical outlet with wet
hands.
Risk of Electrical Shock

7
Do not immerse the compressor (main unit) in water or other liquid.
Do not spill water or other liquids on the compressor and power cord.
These parts are not waterproof. If liquid spills on these parts, immediately
unplug the power cord and wipe off the liquid with gauze or other soft
absorbent material.
Do not use or store the device in humid locations, such as a bathroom.
Use the device within the operating temperature and humidity.
Do not operate the device with a damaged power cord or plug.
Do not use a cellular phone near the device. It may result in an
operational failure.
Do not overload power outlets. Plug the power cord into the appropriate
voltage outlet.
Do not use extension cords. Plug the power cord directly into the electrical
outlet.
Unplug the power cord from the electrical outlet after using the device.
Unplug the power cord from the electrical outlet before cleaning the
device.
Do not pull the power cord of power cord strongly.
Keep the device out of the reach of unsupervised infants and children.
The device may contain small parts that can be swallowed.
Do not leave the cleaning solution in the nebulizer parts. Rinse the
nebulizer parts with clean hot tap water after disinfecting.
Wash the nebulizer parts after each use. Dry the parts immediately after
washing.
Maintenance and Storage

8
Do not store the air tube with moisture or medication remaining in the air
tube. This could result in infection as a result of bacteria.
Store the device and the components in a clean, safe location.
Do not carry or leave the nebulizer kit with medication in the medication
cup.
Do not place or attempt to dry the device, components or any of the
nebulizer parts in a microwave oven.
Do not wrap the power cord around the compressor (main unit) and power
cord.
Components
Know Your Unit
User Manual (including Warranty Card) × 1
Air Filters Package of 2
Product Inspection Certificate × 1
Medical Compressor Nebulizer
Version 1.0
Thank you for choosing AVICHE Medical Compressor Nebulizer. Please read this User
Manual carefully before use and maintenance and keep it properly for future reference.
Model: AH-C10
User Manual
AVICHE Shandong Medical Technology Co., Ltd.
Product Name:
Model No.:
Inspection Date:
Quality Inspector:
Product
Inspection Certificate
Medical Compressor Nebulizer
AH-C10