Conditions for use of this product
(1) AVENTICS G3 Manifold ("the PRODUCT") shall be used in conditions;
i) Where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead to any major or serious
accident.
ii) Where the backup and fail-safe function are systematically or automatically provided outside of the PRODUCT for
the case of any problem, fault or failure occurring in the PRODUCT.
(2) The PRODUCT has been designed and manufactured for the purpose of being used in general industries.
ASCO L.P. shall have no responsibility or liability including but not limited to any and all responsibility or liability based on
contract, warranty, tort, product liability for any injury or death to persons, loss or damage to property caused by the product
that are operated or used in application not intended or excluded by instructions, precautions or warnings contained in
AVENTICS Technical, User, Instruction, Safety manuals or bulletins.
Safety precautions
Before using this product, please read this manual and the relevant manuals carefully and pay attention to safety and product
application. The following symbols are used in the manual to identify important safety, installation and application information.
Caution symbol indicates a possible hazard which may cause injury or equipment damage.
Note symbol indicates important information regarding equipment installation and setup.
NOTE!
CAUTION

G3 Series Wireless ARM Quick Start Manual
3
TDG3ARMQS1-1EN 03/21
Subject to change without notice
www.Emerson.com
Table of Contents
PAGE
Auto Recovery Module (ARM) Introduction .......................................................................................... 4
1. ARM Process Flowchart .................................................................................................................... 5
2. Wireless ARM .................................................................................................................................... 6
2.1 Protocol/Firmware Compatibility
3. Connecting to the Wireless ARM (Computer or Mobile Device) ......................................................... 7
3.1 Network SSID/Security Key
3.2 IP Address
4. Wireless ARM Webserver in "View Only" mode ................................................................................ 9
4.1 How to switch from "View Only" to "Configuration & Parameters Changes" mode
5. Wireless ARM Webserver in "Configuration & Patameter Changes" mode ...................................... 10
5.1 Password Access
5.2 Webserver Functionality
5.3 Two-Factor Authentication (Output Forcing)
6. Returning Wireless ARM to Factory Defaults .................................................................................. 19

G3 Series Wireless ARM Quick Start Manual
4
TDG3ARMQS1-1EN 03/21
Subject to change without notice
www.Emerson.com
Auto Recovery Module (ARM) Introduction
The Auto Recovery Module (ARM) is an optional memory module that is installed between the node and the valve
adapter module and is used to backup the manifold system parameters even during catastrophic failure. During the
power-up process the communication module reads the configuration of the manifold, including any user settable
parameters of I/O modules, and stores the information in its non volatile memory. Once the information is stored, it is
disconnected from the power circuits while still mechanically attached to the manifold.
Description Replacement Part Number
ARM Clip Module 240-383
Wireless ARM Clip Module 240-382
ARM Module (Legacy) 240-182
ARM Module (Legacy)
ARM Clip Module Wireless ARM Clip Module

G3 Series Wireless ARM Quick Start Manual
5
TDG3ARMQS1-1EN 03/21
Subject to change without notice
www.Emerson.com
1. ARM Process Flowchart
ARM function is described in the following flowchart
CONFIG ERROR
XFER G3 TO ARM
CONFIRM XFER
G3 TO ARM YES
RESETTING
CONFIG ERROR
XFER ARM TO G3
CONFIRM XFER
ARM TO G3 YES
RESETTING

G3 Series Wireless ARM Quick Start Manual
6
TDG3ARMQS1-1EN 03/21
Subject to change without notice
www.Emerson.com
2. Wireless ARM
The Wireless ARM supports standard ARM functionality with the addition of a WIFI accessible diagnostic web server. The web
server allows the user to connect to the Wireless ARM to access manifold parameters and diagnostics using any WIFI enabled
device including computers, tablets and smartphones.
Description Replacement Part Number
Wireless ARM Clip Module 240-382
Wireless ARM Minimum Build Firmware Requirements
Protocol Part Number Firmware
EtherNet/IP DLR 240-325 Rev 1.01 Build 43980
ProfiNet 240-240 Rev 1.01 Build 43980

G3 Series Wireless ARM Quick Start Manual
7
TDG3ARMQS1-1EN 03/21
Subject to change without notice
www.Emerson.com
3. Connecting to the Wireless ARM (Computer or Mobile Device)
Once a G3 manifold equipped with a Wireless ARM is powered on; the Wireless ARM will broadcast it’s SSID.
Locate the Wireless ARM broadcast ID
On the computer or mobile device; open available WIFI connections. In this example the SSID is Broadcast as “G3 Numatics
6c5c3c”. Each Wireless ARM Clip’s SSID is unique and comprised of the last 6 digits of the Wireless ARM Clip’s MAC ID.
Select the connection and enter the network security key.
The default network security key is 12345678
Verify the computer/Mobile device is connected to the Wireless ARM Clip.
Default Security Key is 12345678
NOTE!

G3 Series Wireless ARM Quick Start Manual
8
TDG3ARMQS1-1EN 03/21
Subject to change without notice
www.Emerson.com
Open an internet browser and connect to the G3 Wireless ARM webserver by typing the IP address.
(default IP address HTTP:// 192.168.4.1).
“View Only” and “Configuration & Parameter changes” buttons are displayed.
-View Only – connects to the G3 Webserver with read only access.
-Configuration & Parameter changes – connects to the G3 Webserver with write access.
Select “Configuration & Parameter changes” to open the password protected Configuration & Parameter Webpages with Read
and Write Access.
Configuration & Parameter changes are password protected.
NOTE!

G3 Series Wireless ARM Quick Start Manual
9
TDG3ARMQS1-1EN 03/21
Subject to change without notice
www.Emerson.com
4. Wireless ARM Webserver in “View Only” mode
“View Only” mode allows the user read only access. Configuration and parameters are locked and unable to be modified. In
this mode you can monitor the condition of all of the modules in the G3 sub-bus network.
“View Only” mode is identified by the “View only” tag at the top left of the Dashboard page.
To exit “View Only” mode and change to “Configuration & Parameter Changes” mode, close the second open webpage tab from
the top of the screen. The first tab is the landing page where you can select which mode you would like to view the webserver
in.
NOTE: If using a smartphone or tablet, you will need to open a Tabs view to close the “View Only” page and go back to the
landing page.

G3 Series Wireless ARM Quick Start Manual
10
TDG3ARMQS1-1EN 03/21
Subject to change without notice
www.Emerson.com
5. Wireless ARM Webserver in “Configuration & Parameter Changes” mode
Once a G3 manifold equipped with a Wireless ARM is powered on the Wireless ARM will broadcast it’s SSID.
Password Protected Access
Enter password to Access the Configuration & Parameter web pages.
Default Password is G3/240-382
NOTE!
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Manuales populares de Módulo inalámbrico de otras marcas

Cooper Wiring Devices
Cooper Wiring Devices ESPIRE RF RFAPM Manual de usuario

Yuga
Yuga CLM920 Manual de usuario

Waldmann
Waldmann TALK Bluetooth Manual de usuario

Telit Wireless Solutions
Telit Wireless Solutions UC864-G Manual de instalación

Ebyte
Ebyte E07-900M10S Manual de usuario

Quectel
Quectel SC690A Series Suplemento

Panasonic
Panasonic INDUSTRY PAN9028 Guía de configuración rápida

Ebyte
Ebyte E70-433NW30S Manual de usuario

LongSung Technology
LongSung Technology U9507E Manual de usuario

Wistron NeWeb
Wistron NeWeb DNUR-S2 Manual de usuario

Ebyte
Ebyte E49-400M20S4 Manual de usuario

RF-Star
RF-Star SimpleLink RF-BM-2652P1 CC2652P Manual de usuario