AVCLINK HS-81 User manual
7
Serial code:
Output select in1: 0xa5 0x5a 0x00 0xcc
Output select in2: 0xa5 0x5a 0x01 0xcc
Output select in3: 0xa5 0x5a 0x02 0xcc
Output select in4: 0xa5 0x5a 0x03 0xcc
Output select in5: 0xa5 0x5a 0x04 0xcc
Output select in6: 0xa5 0x5a 0x05 0xcc
Output select in7: 0xa5 0x5a 0x06 0xcc
Output select in8: 0xa5 0x5a 0x07 0xcc
Automatic scanning
-Serial turn on code:0xa5 0x5a 0x41 0xcc
-Viewing scanning time
After powering on the LED displays the auto-scanning in seconds by default. The Min on LED indicator
is not lit. Press the Min button to display the auto-scanning in minutes.
Scan time setting
1. Set/Esc: Set the entry / exit scan time.
2. “+” “-” Set scan time plus / minus.
3. Min/Set: Set the scan time between minutes and seconds (when the green LED is always on, it means
that the current status is minutes).
4. Min/On: Green LED Minutes indicator.
Example:
If the user wants to set 18 seconds automatic scanning time, first press Set / ESC. At this time, the LED
light flashes, then press “+” until the LED displays 18, and then press the Set / ESC button. When the
LED lights does not flash, the setting is successful. If the set time is minutes, press Set / ESC first and
then Min / Set. At this time, the green LED lights is always on. Then the user can set the automatic
scanning time, press Set / ESC, the LED lights does not flash and the green LED is always on. At this
time, the scan time is set to minutes.
Signal tracking status description
A: No matter the user first plugs in any input port, it will automatically track and identify any port.
When the input port reaches more than 2 hosts, it does not track
B: When the user input port reaches more than 2, the user unplugs the port that displays the working
picture, it will jump to the next online port in order.