ASTEL MGR100 Manual de usuario

MGR100
GSM
REMOTE
CONTROL
UNIT
Operating Instructions

2
CONTENTS
Preface............................................................................................................................................... 3
Features............................................................................................................................................. 3
Precautions ........................................................................................................................................ 3
Controls And Connectors ................................................................................................................... 4
Installation .......................................................................................................................................... 5
DC power supply and Accumulator connection............................................................................ 5
Control connections ..................................................................................................................... 6
Relays connection ................................................................................................................. 6
Digital outputs connection...................................................................................................... 6
Alarm connections ....................................................................................................................... 7
Digital inputs connection........................................................................................................ 7
Analog inputs connection.......................................................................................................7
Temperature sensors connection .......................................................................................... 8
Other connections........................................................................................................................ 8
Speaker and Microphone connection .................................................................................... 8
Remote keyboard connection................................................................................................ 8
I2C bus connection................................................................................................................ 9
RS-232 connection ................................................................................................................ 9
Instructions....................................................................................................................................... 10
Login.......................................................................................................................................... 10
Controls ..................................................................................................................................... 10
Relays.................................................................................................................................. 10
Digital outputs...................................................................................................................... 11
Alarms........................................................................................................................................ 12
Digital inputs........................................................................................................................ 12
Analog inputs....................................................................................................................... 13
Temperature sensors .......................................................................................................... 14
GPS receiver ....................................................................................................................... 15
Other alarm functions................................................................................................................. 17
Alarm set-up .............................................................................................................................. 19
Other functions .......................................................................................................................... 19
DTMF instructions...................................................................................................................... 21
SIM card locations ..................................................................................................................... 22
Technical Specifications................................................................................................................... 24
Optional Accessories........................................................................................................................ 24
Warranty........................................................................................................................................... 25
Declaration Of Conformity................................................................................................................ 26
_______________________________________________________________________________________________

3
PREFACE
The MGR100 is a high-efficient GSM remote
controller specially designed to use in nautical
applications. Built-in GSM module with
different interfaces enable simple and easy
control and management of complete yacht
electrical and electronic equipment through
GSM mobile phone. Built-in relays enable
remote control of different yacht devices. Alarm
inputs enable remote control of different yacht
systems like pumps, engines and other
systems, voltage measuring and measuring of
temperature and humidity. By the help of
optional GPS receiver the position
management and tracking are enable and
alarming in the case of leaving or approaching
to the hold position.
The control of the unit is possible by the help of
SMS text messages or by the help of tone
(DTMF) dialing. Alarming is possible by
receiving the SMS text messages or by alarm
calls or by the combination of both of them.
Interactive voice responder confirms the
requests during DTMF control or inform about
the kind of alarm when alarm occurs. The unit
enables also speaker and microphone
connection to remote communication.
Programming is possible by the help of SMS
text messages or with PC by the help of RS-
232 serial interface.
This GSM Remote Control Unit comes in three
versions, Basic, Advance and Reference,
every model is available also with GPS
receiver.
FEATURES
built-in GSM module with SIM interface
built-in GPS module for position
management and alarming***
SMS control
DTMF (PSTN, ISDN, GSM) control*
IVR – interactive voice responder**
temperature measuring and management*
analog voltage measuring and
management*
alarm sensor management
remote keyboard interface
speaker and microphone interface**
PC remote and local management**
wide range power supply
ABS casing
accumulator connection
PRECAUTIONS
The remote control unit has to be installed
and used in accordance with the
instructions of this manual only.
The power supply has to be disconnected
before installation.
Avoid using the remote control unit under
the presence of appliances generating
strong magnetic fields like radar, wheather
station and in places subject to direct
sunlight.
Do turn power off immediately and refer
servicing to qualified service personnel if
the remote control unit does not operate
normally following the operating
instructions.

4
CONTROLS AND CONNECTORS
(1) DIGITAL IN
Terminal block to connect 8 different sensors.
(2) OPEN C.*
Terminal block to connect 4 different relays or
other control units.
(3) RELAY*
Terminal block to connect 4 different devices.
(4) DC - ACCU
Terminal block to connect Accumulator and DC
power supply.
(5) GPS antenna connector***
SMA connector to connect GPS antenna.
(6) Status LED
LED to show the status, LED blinks in normal
operation.
(7) Alarm LED
LED to show the alarm status, lights when
alarm occurs.
(8) GSM antenna connector
SMA connector to connect GSM antenna.
(9) RS-232**
Terminal block to connect RS-232 control
equipment.
(10) SP – MIC**
Terminal block to connect Speaker and
Microphone.
(11) REMOTE**
Terminal block to connect external keyboard.
(12) ANALOG IN*
Terminal block to connect 4 different voltage
sources.
(13) I2C**
Terminal block to connect I2C control
equipment.
(14) SENSOR*
Terminal block to connect 3 temperature or
other sensors.
(15) GSM module LED
LED to show the GSM module status, lights in
normal operation..

5
INSTALLATION
All the diagrams in this manual show the installation of the GSM Remote Control Unit, model
MGR100G REFERENCE.
Note:
The main DC power supply has to be switched off before installation.
Also refer to the instruction manual of the equipment to be connected.
The total power consumption of all sensors, relays and other devices supplied from the
unit has not exceed 500mA.
The MGR100 series remote control unit have to be installed near the control board. Avoid the
installation in engine room, extremely hot places and near appliances generating strong magnetic
fields. The installation have to be realize by a qualified personel.
Note:
The GSM and GPS antennas have to be connected before the unit is switched-on.
The SIM card have to be inserted before the unit is switched-on. The SIM location 3
(password) has to be empty. The PIN code request have to be disabled.
DC power supply and Accumulator connection
The power supply have to be connected to the DC terminal block connector with right polarity and
protected with a fuse (not included). The power supply voltage have to be from 12 - 30VDC. The
back-up accumulator have to be connected to the ACCU terminal block connector with right polarity
and also protected with a fuse (not included).
Note:
The declared accumulator voltage have to be the same as the DC power supply voltage.
F0.5A F0.5A

6
Control connections
Relays connection*
The relay control outputs are suitable to control four different yacht electrical and electronic devices,
connected directly or through external relays. First two relays have NO and NC contacts, other two
relays have only NO contacts.
Note:
The total DC curent consumption of connected equipment to each relay must not exceed
1A when the equipment are controlled directly from the unit. The maximum voltage
connected to the relays must not exceed 30V.
Digital outputs connection*
The digital outputs are suitable to control four different yacht electrical and electronic devices
connected through external relays.
Note:
The total DC curent consumption of each connected relay must not exceed 100mA.
PP P
P
DC
F1
N
P
P+
DC
GND
F1
+
DC
N

7
Alarm connections
Digital inputs connection
The digital inputs are suitable to connect eight different sensors like IR intruder sensors, smoke
sensors, water inlet sensors (floating switches) with NO or NC contacts. The sensors can be supplied
directly from the unit and connected to one of +ACCU terminal block.
Note:
The total power consumption of each sensor supplied from the unit must not exceed
100mA.
Analog inputs connection*
The analog inputs are suitable to connect four different voltage sources like are boat accumulators
and to measure their voltages.
Note:
Only the DC voltage can be connected to the analog inputs.
The maximum DC voltage connected to each input must not exceed 30Vdc.
S1 S3 S5 S7
S2 S4 S6 S8

8
Temperature sensors connection*
The unit is designed to connect maximum three temperature sensors to measure the temperature in
different places like are engine room, saloon, rooms and cockpit or fly-bridge.
Note:
Only the specified sensors can be connected to the temperature sensors inputs.
Other connections
Speaker and Microphone connection**
The unit is designed to connect the microphone which enables to listen the voice and low-power
speaker for communication and notification.
Note:
Only the specified speaker and microphone can be connected to the unit.
Remote keyboard connection**
The unit is designed to connect the simple remote keyboard which enables operating with the unit to
enable and disable the alarming and other functions.
Note:
Only the specified remote keyboard can be connected to the unit.
T1 T2 T3

9
I2C bus connection**
The unit is designed to connect also the devices using the I2C protocols.
Note:
Only the devices using I2C protocol can be connected to the I2C interface.
RS-232 connection**
The unit is designed to connect also the devices using the RS-232 serial interface control like
personal computer or other devices.
Note:
Only the devices using RS-232 serial interface can be connected to the RS-232 port.
KEYBOARD
I2C bus
device
PC

10
INSTRUCTIONS
Login
The default setting of password is 1234.
To send the password
PWDxxxx x=1..9
PWD1234 (if the password is 1234)
(PWD instruction should be uppercase, other instructions uppercase or lowercase)
PWD1234_instr1_instr2_instr3
(first should be sent the password then space and then instructions)
To change the password
NPWxxxx x=1..9
NPW2222 (if the new password is 2222)
Controls
Relays*
To receive a status of relays:
REL
Received SMS:
NAME
REL1:REL1:12.10.00
REL2:REL2:ON
REL3:REL3:OFF
REL4:REL4:REM
To switch-on the relay:
RELxON x=1..4
REL1ON (to switch-on the relay 1)
To switch-off the relay:
RELxOFF x=1..4
REL1OFF (to switch-off the relay 1)
To switch-on the relay for selected time duration:
RELxONhh.mm x=1..4
hh=0..24
mm=0..60
ss=0..59
REL1ON12.10.00 (to switch-on the relay for 12 hours, 10 minutes)
Tabla de contenidos
Otros manuales de Unidad de control de ASTEL
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario












