Strain gauge switching amplifier BS 805.01 / BS 805.11 / BS 805.21
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
Marschnerstraße 26 01307 Dresden
phone (03 51) 44 55 30 fax (03 51) 44 55 555


Manual switching amplifier BS 805
Subject to technical change 10/2017 1
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
Index of contents
1.Safety Instructions ............................................................................................................................... 1
2.Wiring Diagram ..................................................................................................................................... 2
3.Operating elements .............................................................................................................................. 2
3.1.Adjustments ........................................................................................................................................ 4
3.2.Button .................................................................................................................................................. 4
4.LED- display .......................................................................................................................................... 4
5.Function of key T1 ............................................................................................................................... 5
5.1.Code table ........................................................................................................................................... 5
5.2.Example .............................................................................................................................................. 6
6.Information on Performance-Level PLc in accordance with DIN EN 13849-1 ............................... 6
6.1.Classification of Type Series “Switching Amplifier BS 805” ................................................................ 6
6.2.Error detection in operation with a connected sensor ........................................................................ 6
6.3.Other functions .................................................................................................................................... 7
7.Commissioning .................................................................................................................................... 7
7.1.Mounting ............................................................................................................................................. 7
7.2.Connection .......................................................................................................................................... 7
7.3.Signal settings ..................................................................................................................................... 8
7.4.Control of settings ............................................................................................................................... 9
8.Specification ....................................................................................................................................... 10
9.EC Declaration of Conformity ........................................................................................................... 11


Manual switching amplifier BS 805
Subject to technical change 10/2017 Page 1 of 12
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
1. Safety Instructions
ATTENTION!
Any non-compliance with these safety precautions may result in severe damage to property and health!.
ATTENTION!
These Operating Instructions explain the installation, bringing into service, and operation of the type BS
805.0x amplifier. It is assumed that every action is taken by qualified staff only who have adequate
knowledge in the fields of measuring and control engineering.
The equipment must be installed and attached under adherence to of the current DIN and VDE
standards.
ATTENTION!
The type BS 805.01 Strain-Gauge amplifier has been designed to the purpose of amplifying the output
signals of sensors with metal-foil strain gauges, preferably force transducers.
The type BS 805.02 has been designed to the purpose of amplifying the output signals of sensors with
standard signal 4-20mA, preferably force transducers.
Any other application is regarded contrary to intended usage.
The BS 805.0x may not be used as exclusive means for the prevention of dangerous conditions at
machines and plants.
Make sure that any erroneous setting or malfunction of the unit or its break-down cannot cause damage
or be a risk to the staff or other persons.

Manual switching amplifier BS 805
Page 2 of 12 Subject to technical change 10/2017
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
2. Wiring Diagram
BS 805.01 / BS 805.21
0
V
-SI-EX
+SI+EX
1
-X1
+EX
2
-EX
3
+SI
4
-SI
6
0mA
7
10-30VDC
8
GND
SP1
1
-X10
1NC1
2COM1
3NO1
-X11
1NC2
2COM
2
3NO2
-X12
1PE1
2PE2
µC T1
SP2
1
T1
?t
Force transducer
Power supply
A
Standard signal output
5
4-20mA
BS 805.11
Force transducer
Standard signal output
Power supply 230VAC
0
V
-SI-EX
+SI+EX
1
-X1
+EX
2
-EX
3
+SI
4
-SI
5
4-20mA
6
0mA
SP1
1
-X10
1NC1
2COM1
3NO1
-X11
1NC2
2COM
2
3NO2
-X5 1
L
2
N
µC T1
SP2
1
T1?t
3
PE
7
8
A
-X12
1PE1
2PE2
3. Operating elements
BS 805.01 Strain gauge switching amplifier
Supply voltage 10…30VDC / case IP65 – die cast
Cable gland M20
D =
6
… 12mm
Cable gland M16
D = 5 … 10mm
>V<>T1<
>LED-i.O.<
(U78)
>LED-SP1<
>SP1<

Manual switching amplifier BS 805
Subject to technical change. 10/2017 Page 3 of 12
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
BS 805.11 Strain gauge switching amplifier
Supply voltage 230VAC /case IP65 – die cast
Setup
>V<>T1<
>LED-i.O.<
(U78)
>LED-SP1<
>SP1<
Cable gland M20
D = 6 … 12m
m
Cable gland M16
D =
5
… 1
0
m
m
BS 805.21 Strain gauge switching amplifier
Supply voltage 10…30VDC / case IP40 – DIN rail
>V<>T1<
>LED-i.
O
.<
(U78)
>LED-
S
P1<
>SP1<
SH
SH
PE
PE
+EX
-EX
NC1
NC2
COM1
COM2
NO1
NO2
+SI
-SI
4-20
mA
0mA
24V
+
-
Schaltverstärker
BS 805
SP1
>V<
20
Power
T1
mA
>0<
4
SP2
>D<

Manual switching amplifier BS 805
Page 4 of 12 Subject to technical change 10/2017
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
3.1. Adjustments
3.2. Button
4. LED- display
Switch Function
Strain gauge switching amplifier
BS 805.01
BS 805.11
BS 805.21
>V< 16 mA - characteristic value setting 0,8 … 2,5mV/V
>0< 4mA - setting to zero point -0,5 … +0,5mV/V
SP1 Switching point setting/ switching range 4....20mA
SP2 Switching point setting/ switching range 4....20mA
D Switching delay for SP2 0 ... 5sec.
Switch Function
T1 Additionally function see Point 5
LED Normal operations Error (flashing display)
U1 <4mA incorrect code enter
U2 4mA < I < 8mA
U4 8mA < I < 12mA -
U8 12mA < I < 16mA -
U16 16mA < I < 20mA -
U32 20mA < I -
U78 Ready for operation break or short in sensor wire
blinks once Current level exceeded through +EX
for BS805.y1 bridge resistance < 300
for BS805.y1 sensor current > 40mA
blinks twice Current level not attained through +EX
Only for BS805.y1 bridge resistance > 1000
blinks 3 times Input signal exceeded
for BS805.y1 bridge signal = > +2.5mV
blinks 4 times Input signal not attained
for BS805.y1 bridge signal < -2.5mV/V
blinks 5 times Bridge median voltage exceeded
only for BS805.y1 (–SI zu –EX >2.2V)
blinks 6 times Bridge median voltage not attained
only for BS805.y1(–SI zu –EX <1.2V)
U21 SP1 current on -
U22 SP2 current on -

Manual switching amplifier BS 805
Subject to technical change. 10/2017 Page 5 of 12
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
5. Function of key T1
5.1. Code table
Element Function Code
Relay 1 Normal from
appointed SP1
current less
211
Inverse from
appointed SP1
current on
212
Hysterese 0,0mA 230
Hysterese 0,1mA 231
Hysterese 0,5mA 232
Hysterese 1,0mA 233
Hysterese 2,0mA 234
Relay 2 Normal from
appointed SP2
current less
221
Inverse from
appointed SP2
current on
222
Hysterese 0,0mA 240
Hysterese 0,1mA 241
Hysterese 0,5mA 242
Hysterese 1,0mA 243
Hysterese 2,0mA 244
Mandatory security
SP1
Switching attitude
SP1, SP2: normal,
adjustment SP1: to
2mA over SP2,
fault: SP1 and SP2
current less and
output signal 2mA
251
Relay 1 and Relay 2 Reset at normal 255
Constant current 4,0 311
(mA) 12,0 312
20,0 313
+ 0,2 344
+ 0,5 343
+ 1,0 331
+ 2,0 332
+ 3,0 333
+ 4,0 334
+ 5,0 335
- 0,2 341
- 0,5 342
- 1,0 321
- 2,0 322
- 3,0 323
- 4,0 324
- 5,0 325
Example 16,8=12,0+5,0-0,2 “312”+”335
”+”341”
Current to reset Back to measuring
mode
355 or
voltage
supply 10–
30VDC to
break
Element Function Code
Basic setting
(only BS 805.01 )
SP1: normal / without
hysteresis
SP2: normal / without
hysteresis
Strain gauge input
positive
Zero point -/+ 0,5
mV/V
555
Setup-protection on 421
off 425
Strain gauge input tension and
compression:
12mA=0mV/V
411
Negative 412
Positive 415
Test signal on 422
off 423
>V< - limit stop left ∆16mA = ∆2,0mV/V 431
∆16mA = ∆1,5mV/V 432
∆16mA = ∆1,0mV/V 433
∆16mA = ∆2,5mV/V 435
>V< - limit stop right ∆16mA = ∆0,5mV/V 441
∆16mA = ∆1,0mV/V 442
∆16mA = ∆1,5mV/V 443
∆16mA = ∆0,83mV/V 445
>0< - adjusting range - 1,00 ... 0,00mV/V 451
- 0,75 ... +0,25mV/V 452
- 0,25 ... +0,75mV/V 453
0,00 ... +1,00mV/V 454
- 0,50 ... +0,50mV/V 455

Manual switching amplifier BS 805
Page 6 of 12 Subject to technical change 10/2017
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
5.2. Example
6. Information on Performance-Level PLc in accordance with DIN EN 13849-1
6.1. Classification of Type Series “Switching Amplifier BS 805”
The Switching Amplifier BS805 can be classified in the Performance-Level PLc in accordance with the set of
standards governing Safety Relevant Control Systems DIN EN 13849-1.
This then covers hazards as shown in the hazard graphs below recommended for safety-relevant control systems in
conjunction with the Performance-Level PLc and SK1 Category.
Severity of injury (S)
S1 Slight injury (usually temporary)
S2 Severe injury (usually irreversible),
including death
Frequency and/or duration of exposure to
hazard (F)
F1 ... Seldom to quite often and/or short
duration of exposure
F2 ... Frequent to permanent and/or short
duration of exposure
Possibility of preventing the hazard (P)
P1 ... Possible under certain conditions
P2 ... Hardly possible
6.2. Error detection in operation with a connected sensor
The Switching Amplifier BS805 identifies the following errors:
Sensor monitoring
- Wire breakage, also on single core of sensor cable.
- Short circuit on any number of cores of sensor cable.
- “Unsafe” connection of individual cores.
Internal monitoring
- Failure of operating voltage
- Failure of sensor power supply
The BS 805 is responding to an error with:
- Relay SP1 and SP2 fall (to drop out)
- LED U78 blinking
- Output signal is 2mA
sequence Operation for Code 341 LED-display
1. 3-times press >T1< >U2-U4-U8< light
2. Wait approx. 2 sec Light off
3. 4-times press >T1< >U2-U4-U8-U16< light
4. Wait approx. 2 sec Light off
5. 1-times press>T1< >U2< light
6. end LED >U16< flashing approx. 2 sec
S
1
Starting
point for
assessing
risk
reduction
Low
risk
R
equ
i
re
d
performanc
e
level PL
High
risk
a
b
c
d
e
F
1
P
1
P
1
P
1
P
1
F
1
S
2
F
2
P
2
P
2
P
2
P
2
F
2
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Amplificador de AST