ASL INTERCOM VAR8 Manual de usuario

VAR8 and Variants
Audio Router and System Controller
ASL Document Ref.: U-0450-1360.doc
Issue: 02 - complete, approved - Date: 18/08/10
Part Number: M0450_51
Installation Guide

VAR8 / Variants - Installation Guide
This equipment is designed and manufactured to conform to the following
EC standards:
EMC EN55103-1/E1, EN55103-2/E5, EN50121-4, EN50130-4, EN61000-6-3,
ENV50204
Safety EN60065
Failure to use the equipment in the manner described in the product literature will
invalidate the warranty.
A 'Declaration of Conformity' statement to the above standards, and a list of
auxiliary equipment used for compliance verification, is available on request.
This product must be disposed of in accordance with the WEEE directive.
Copyright © 2007 Application Solutions Limited
Application Solutions Limited
Head Office: The Riverside Centre
Railway Lane
Lewes - East Sussex
BN7 2AQ - UK
Tel: +44(0)1273 476608 Fax +44(0)1273 478888
Voice Alarm Direct: Tel: +44(0)1273 405411 Fax: +44(0)1273 405415
www.asl-electronics.co.uk
All rights reserved.
Information contained in this document is believed to be accurate, however no representation or warranty is given
and Application Solutions Limited assumes no liability with respect to the accuracy of such information.
Issue: 01 complete, approved
Page 2 of 22

VAR8 / Variants - Installation Guide
Contents
1Installation ...................................................................................................................................... 5
1.1 Installation Requirements................................................................................................. 6
1.1.1 Cabling Requirements .............................................................................................. 6
1.2 Recommended Installation Procedure ............................................................................. 9
1.3 Link Settings for Stand-Alone, 1 or 2 Channel Only Network Operation ....................... 11
2Connections ................................................................................................................................. 12
3Product Specification.................................................................................................................. 16
4Mechanical Dimensions .............................................................................................................. 19
5Safety and Precautions ............................................................................................................... 20
5.1 Environmental................................................................................................................. 20
5.2 ESD ................................................................................................................................ 20
5.3 EMC................................................................................................................................ 20
5.4 Electrical Safety.............................................................................................................. 20
5.5 Lithium Battery................................................................................................................ 20
5.6 Unpacking and Handling ................................................................................................ 20
5.6.1 Packing for Repair .................................................................................................. 20
6Reference Documentation .......................................................................................................... 21
7Service and Warranty .................................................................................................................. 22
7.1 Exclusions ......................................................................................................................22
Issue: 01 complete, approved
Page 3 of 22

VAR8 / Variants - Installation Guide
This page intentionally left blank.
Issue: 01 complete, approved
Page 4 of 22

VAR8 / Variants - Installation Guide
1 Installation
The following drawing shows the standard base model VAR8 connectors as well the Interface
Expansion Board and Network Interface Card connectors. Note that the Interface Expansion Board
(EXP8) and the Network Interface Card (ANIC8) are optional items.
Section “2 Connections” on page 12 describes the signals in each connector.
Figure 1 VAR8/Variant Connections
DOWNSTREAMUPSTREAM
NETWORK INTERFACE CARD (ANIC8)
V+NB
ACO1
V+NB
IN+
GND
0V
INPUT 4
DXP
V+NB
INPUT 6
V+
0V
DXN
IN+
IN-
DXP
DXN
DXN
DXP
DXN
DXP
V+
0V
IN+
IN-
DXN
V+NB
V+
0V
IN-
IN+
DXP
ACO2
SN2
INPUT 2
PTT2-
0V
V+
IN-
IN+
PTT2+
0V
DXP
DXN
V+
IN-
IN+
V+
PTT1-
PTT1+
SN1
IN-
IN+
C1+
GND
V+
5-8
A-
A+
CANH
CANL
RTS
CTS
CTRL
DXN
GND
COM
NC
NO
1-4
GND
RX
TX
DXP
C5+
C1-
C4+
C4-
C3+
C2+
C3-
C2-
C5-
AUDIO
OUTPUT INPUT 3 INPUT 5INPUT 1
SERIAL
RS232
CONTROL
CONTACTS 5-1
FAULT
RELAY
SERIAL
RS232
AUDIO
OUTPUT
AUDIO
MON
CAN
BUS
SERIAL
RS485
1 FAULT
2 FAULT
3 FAULT
1 FAULT
2 FAULT
3 FAULT
DOWN / UP
V+NB
V+
DXP
0V
DXN
IN+
IN-
V+NB
DXP
V+
DXN
0V
IN+
IN-
SCRN
DXP
DXN
BUS1+
BUS1-
BUS2+
BUS3-
BUS3+
BUS2-
GND
DXP
DXN
BUS1+
BUS1-
BUS2+
BUS3-
BUS3+
BUS2-
INPUT 8INPUT 7 MUSIC
1234
POWER
V+
V+
GND
GND
ON
C10+
C7-
C7+
C6-
C6+
C9+
C9-
C8+
C8-
C10-
CONTROL
CONTACTS 10-6
C20+
C17-
C17+
C16-
C16+
C19+
C19-
C18+
C18-
C20-
CONTROL
CONTACTS 20-16
C15+
C12-
C12+
C11-
C11+
C14+
C14-
C13+
C13-
C15-
CONTROL
CONTACTS 15-11
OUT-1A-
OUT3-A+
OUT4-A-
OUT4-A+
OUT2-A-
OUT-1A+
OUT3-A-
OUT2-A+
0V
A OUTPUTS 1-4
OUT5-A-
OUT7-A+
OUT8-A-
OUT8-A+
OUT6-A-
OUT5-A+
OUT7-A-
OUT6-A+
A OUTPUTS 5-8
OUT1-B-
OUT3-B+
OUT4-B-
OUT4-B+
OUT2-B-
OUT1-B+
OUT3-B-
OUT2-B+
0V
B OUTPUTS 1-4
OUT5-B-
OUT7-B+
OUT8-B-
OUT8-B+
OUT6-B-
OUT5-B+
OUT7-B-
OUT6-B+
B OUTPUTS 5-8
INTERFACE EXPANSION BOARD (EXP8)
DIP
SW
All DIP switches must be on the OFF position (default) as shown in the drawing.!
Issue: 01 complete, approved
Page 5 of 22

VAR8 / Variants - Installation Guide
1.1 Installation Requirements
• The VAR8 unit.
• A 19-inch standard rack wired and configured with V400 amplifier mainframes, and wiring for
power supply, signal monitoring, CAN bus, and RS232 and RS485 cabling as appropriate.
• A small flat-bladed screwdriver.
• Large pozidrive screwdriver.
• Cable termination tools - cutters/strippers etc. to suit cable type.
1.1.1 Cabling Requirements
The following cabling is recommended within the equipment rack. For pinout refer to Figure 1 (page
5), and for cabling connector refer to Section “2 Connections” (page 12).
1. DC power supply cabling:
Standard cable rated for 3A.
Recommended type: BELDEN 8205LSHF.
2. Audio input:
Twisted pairs, individually screened.
Recommended type: BELDEN 8451 LSHF.
The rack and field cabling should be as described in the diagram shown in Figure 3.
3. A/B audio outputs on Interface Expansion Board (EXP8):
Twisted pairs, individually screened.
Recommended type: BELDEN 8451 LSHF.
The rack and field cabling should be as described in the diagram shown in Figure 3.
4. Audio and data network cabling (on VAR8 with Network Interface Card):
Twisted pairs with overall foil screen.
Recommended type: FS cables 2407 POFYH.
The Upstream side of the network connection is isolated RS485. To maximise the benefits of this,
the rack and field cabling should be as described in the diagram shown in Figure 2.
5. Other cabling:
Overall screened.
Recommended type: BELDEN LS0H.
The rack and field cabling should be as described in the diagram shown in Figure 3.
6. Audio outputs on RJ45 (see signals and pinout in Table 1, page 13):
Cabling: overall foil screened.
Recommended type: CAT5 STP or FTP LS0H
The rack and field cabling should be as described in the diagram shown in Figure 3.
The use of screened cables where specified is necessary for EMC compliance. Also for
EMC compliance, rack and field cabling should be according to the specified diagram.
!
!
Issue: 01 complete, approved
Page 6 of 22

VAR8 / Variants - Installation Guide
Figure 2 Network Termination
VAR8
NETWORK
UPSTREAM
BUS3-
BUS3+
BUS2-
BUS2+
BUS1-
BUS1+
DXN
DXP
GND
100nF 100V
(Reference: RS 211-5340)
DIN RAIL
FIELD CABLING RACK CABLING
NETWORK
DOWNSTREAM
DXN
DXP
SCREEN
BUS3-
BUS3+
BUS2-
BUS2+
BUS1-
BUS1+
DIN RAIL
FIELD CABLING RACK CABLING
Issue: 01 complete, approved
Page 7 of 22

VAR8 / Variants - Installation Guide
Figure 3 Audio I/O and Other Signal Termination
DIN RAIL
EARTH TERMINAL
WEIDMÜLLER PART NUMBER: WPE4 SIGNAL TERMINAL
WEIDMÜLLER PART NUMBER: WDU2.5
DIN RAIL ELECTRONICALLY BONDED
TO RACK
!
SHORT TAIL < 4cm
RACK WIRING
FIELD WIRING
SCREEN
SCREEN
SHORT TAIL < 4cm
RACK EARTH TERMINAL
BONDED TO THE DIN
RAIL
!
Issue: 01 complete, approved
Page 8 of 22

VAR8 / Variants - Installation Guide
1.2 Recommended Installation Procedure
Please read and observe the “Safety and Precautions” section on page 20 of this
manual.
1. If installing a VAR8 with a Network Interface Card, note that the Network Interface Card is
configured, by default, for network operation using 3 audio network channels. If stand-alone
operation or 1 or 2 channel only network operation is required, set the links on the Router board
as described in Section “1.3 Link Settings for Stand-Alone, 1 or 2 Channel Only Network
Operation” on page 11.
2. Mount the VAR8 into a 19-inch standard equipment rack.
DSP Audio Router
power
processor
comms
fault
SELECT BACK
DEFAULT LAMP
TEST
FAULT
CLEAR
FAULT
ACCEPT
AUDIO
MON
2U
M6 PAN HEAD POZIDRIV SCREW
M6 PLAIN WASHER
M6 CAGE NUT
Ensure that there is at least 1U of ventilated space between the unit and any source
of heat (e.g. V400 amplifier mainframes).
3. Connect the rack and field cabling for control ports, audio inputs, audio outputs, signal monitoring,
CAN bus, RS232, and RS485, as appropriate.
Wiring to each VAR8 connector should be according to the diagram shown in Figure
3on page 8for EMC compliance.
!
!
!
!
!
!
The following drawings indicate the position of the connectors on the rear panel. Note that upper
control port, A/B output, and network interface connectors may not be present, depending on the
VAR8 variant being installed.
Figure 1 on page 5shows details of each connector. Section “2 Connections” on page 12
describes the signals.
CONTROL PORTS
ADDITIONAL CONTROL PORTS
(ON EXP8 ONLY)
AUDIO INPUTS
Issue: 01 complete, approved
Page 9 of 22

VAR8 / Variants - Installation Guide
ENHANCED
AUDIO A OUTPUTS
(ON EXP8 ONLY)
STANDARD
AUDIO OUTPUTS
ENHANCED
AUDIO B OUTPUTS
(ON EXP8 ONLY)
RS232
RS485
FAULT RELAY
CAN BUS
AUDIO MONITORING
(See pinout in Table 1, page 13.)
4. Connect the rack and field cabling for the network interface (if the ANIC8 Network Interface Card
is used).
Wiring should be according to the diagram shown in Figure 2 on page 7 for EMC
compliance.
!
!
Figure 1 on page 5shows details of each connector. Section “2 Connections” on page 12
describes the signals.
NETWORK UPSTREAM
NETWORK DOWNSTREAM
5. Connect the dual power supply (as appropriate) to the rear panel connector.
Section “2 Connections” on page 12 describes the signals.
POWER SUPPLY
GND +V GND +V
6. The installation is now complete and ready for system commissioning.
Refer to the Commissioning Guide [Table 2 - 3].
Issue: 01 complete, approved
Page 10 of 22