Table of Contents
Introducon ......................................................................................................... 3
Intended Use ........................................................................................................ 3
Warnings and Precauons ................................................................................... 4
DiskCover System Components and Accessories ................................................ 4
Descripon ........................................................................................................... 5
Install/Replace Clean Cassee ............................................................................. 6
DiskCover System Use .......................................................................................... 7
Clean/Disinfect Dispenser .................................................................................... 8
Dispenser Installaon .......................................................................................... 8
Install/Replace Baeries ...................................................................................... 9
Dispenser Replacement ....................................................................................... 9
Clean Cassee Disposal .....................................................................................10
Light Indicators for Normal Operaon .............................................................. 10
Troubleshoong .................................................................................................11
Specicaons .....................................................................................................13
Symbols .............................................................................................................. 14
Warranty ............................................................................................................ 15
Support ..............................................................................................................15

3
Introducon
Intended Use
AsepScope™ disk covers have been proven eecve in providing an
asepc stethoscope barrier to reduce potenal pathogen transmission.1
The AsepScope™ DiskCover™ System automates the touch-free applicaon of
AsepScope disk covers to stethoscope diaphragms to ensure hygienic paent
contact. The DiskCover System includes a wall-mounted dispenser that houses a
Clean Cassee™ containing single-use disk covers. Once applied, the disk cover
helps prevent pathogen transmission1 without compromising the sound quality2
of the stethoscope. The DiskCover System requires no formal training, takes
seconds to apply an asepc barrier, and provides clinicians a clean stethoscope
surface for immediate use.
The DiskCover System automates the touch-free applicaon of single-use disk
covers to stethoscope diaphragms as an asepc barrier for hygienic paent
contact to prevent pathogen transmission. The DiskCover System is intended for
use in all clinical sengs.

4
DiskCover System Components and Accessories
DiskCover Dispenser, with 3-Alkaline C baeries DSA-1
DiskCover Clean Cassee, containing roll of DiskCover Disks CSA-1
Wall Mount WMS-01
Placard DSA-L1
Warnings and Precauons
• Read all instrucons prior to use.
• For use on intact skin only. Do not place the disk cover over open wounds.
• Do not install in locaon where the dispenser is exposed to extreme cold or
hot condions or in wet environments such as showers.
• Do not install in areas with less than 7” clearance above and below the wall
mount.
• Do not install without using a level.
• Do not use the dispenser or Clean Cassee if there is visible physical damage.
• Disk covers are single use only. Do not reuse.
• Only use Clean Cassees provided by AsepScope.
• Install only Alkaline C baeries.
• Dispose of used Clean Cassees in accordance with federal, state or local
regulaons.
• Do not use disinfectants containing hydrogen peroxide or other abrasive
agents on the dispenser as it may cause damage.
• USB port for service technician use only.
• Do not use excessive force when applying the disk cover.

5
Descripon
1. Dispenser lid
2. Applicaon window
3. Stethoscope tube notch
4. Light ring
5. Clean Cassee indicator light
6. Safety sensor*
7. Baeries indicator light
8. Acvaon sensor
Dispenser - Front Dispenser - Back
Clean Cassee - Front Clean Cassee - Boom
9. Baery compartment
10. Baery door
11. USB port
12. Mounng rails
13. Clean Cassee handle
14. Disk cover window
15. Shipping insert
16. Release tabs
*Senses objects that could potenally disrupt the proper advancement and posioning of a new disk cover in the
applicaon window. If the sensor is triggered and disk cover halted before being fully placed in the applicaon
window, see DiskCover System Use for acvaon steps.
DiskCover Disk (disk cover) Wall Mount

6
Install/Replace Clean Cassee
1. Remove Clean Cassee from
protecve bag (Figure 1).
2. Remove shipping insert from boom
of cassee (Figure 2).
3. Open dispenser lid.
4. If replacing, li the used Clean
Cassee by its handle and remove.
5. Orient the new Clean Cassee this
side up, as indicated by up arrow,
with disk cover window facing
toward you (Figure 3).
6. Holding the Clean Cassee handle,
gently lower Clean Cassee into
dispenser (Figure 4).
7. Close dispenser lid.
8. If a Clean Cassee has been properly
installed, a green Clean Cassee
indicator light will briey illuminate
(Figure 5).
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5

7
DiskCover System Use
1. WAVE: Grasp the back of the
diaphragm and wave under the
touch-free sensor (right side of the
dispenser) (Figure 6).
2. APPLY: Aer light ring turns green,
rmly place the stethoscope
diaphragm into the applicaon
window. (Be sure stethoscope tubing
ts within the notch) (Figure 7).
3. REMOVE: Withdraw the stethoscope
– a DiskCover Disk is now applied!
(Figure 8)
4. Aer paent exam, pull the white
tab of the disk cover away from the
stethoscope and dispose of properly
(Figure 9).
Visit DiskCover.com for virtual Instrucons for Use and more informaon.
IMPORTANT: A Clean Cassee must be
installed to acvate the dispenser.
Figure 6
Figure 7
Figure 8
Figure 9

8
Clean/Disinfect Dispenser
Dispenser Installaon
The dispenser can be cleaned with mild soap and damp cloth or with non-
abrasive disinfecng agents.
1. Properly orient wall mount as
indicated by up arrows facing outward,
ensuring horizontal edge is level and
with 7” clearance above and below
the wall mount (Figure 10).
2. Secure the wall mount to the wall with
appropriate screws (Figure 10).
3. Posion the dispenser above the wall
mount, align with the rails and
slide down onto the edges of the wall
mount (Figure 11) unl the dispenser
clicks into place (Figure 12).
4. Install baeries (see Install/Replace
Baeries secon).
5. Install Clean Cassee (see Install/
Replace Clean Cassee secon).
Figure 10
Figure 11
Figure 12

9
Dispenser Replacement
1. Remove Clean Cassee and baeries.
2. While holding the sides of the dispenser,
locate the release tabs near the top of
the wall mount (gure 15) and press
towards the center (Figure 16).
3. While depressing the tabs, raise the
dispenser unl clear of the wall mount
(Figure 17).
4. If replacing the dispenser,
see Dispenser Installaon secon.
Figure 16
Figure 15
Install/Replace Baeries
1. Open baery door
2. If replacing baeries, remove
depleted baeries and dispose
appropriately.
3. Insert three (3) C baeries as shown
on the inside baery door, placing
center baery in last (Figure 13).
4. Close baery door. If properly
installed, the baeries indicator light
will briey appear green. Dispenser
will be ready for acvaon aer 3
seconds (Figure 14).
Figure 13
Figure 14
Figure 17

10
Clean Cassee Disposal
Light Indicators for Normal Operaon
The Clean Cassee is made from recyclable plascs but contains other materials
that cannot be recycled. AsepScope oers a Clean Cassee recycling service.
Contact customer service for details.
Illuminang green light ring
(in sequence)
Wait, disk being advanced into posion
Solid green light ring (briey
illuminated)
Disk cover is in posion and ready for
applicaon (Note: the light ring will not remain
green, however, a disk cover can be applied
whenever a disk cover is fully visible in the
applicaon window.)
Blinking red Clean Cassee
indicator light
<15 disk covers remaining in the Clean Cassee,
replace Clean Cassee immediately to prevent
disrupon of dispenser use
Blinking red baeries
indicator light
<10% of baery life remaining, replace
3-Alkaline C baeries immediately to prevent
disrupon of dispenser use
Solid green Clean Cassee
indicator light
(briey illuminated)
An authencated Clean Cassee has been
installed and dispenser is ready for use.
Solid green baeries
indicator light
(briey illuminated)
Baeries installed properly
Este manual sirve para los siguientes modelos
4
Tabla de contenidos