Artel Fiberlink 3370 Series Manual de usuario

Fiberlink®
3370 Series
3G/HD/SD-SDI Transmission and
10/100 Ethernet & 2 Channels of RS-Type Data
over one single mode or two multimode bers.
World Headquarters
55 Cabot Court
Hauppauge, New York 11788 USA
Tel: (631) 273-0404
Fax: (631) 273-1638
commspecial.com
Communications Specialties’ Fiberlink® 3370 User’s Manual
Broadcast quality 3G/HD/SD-SDI,
10/100 Ethernet and 2 channels of
RS-Type data over one single
mode or two multimode bers.
All data channels are available
simultaneously!
Single Color (Black)
Single Color (Black)
on Black Background
If you need to use the CSI logo on a non-solid
background use the Photoshop Layered Files.
©2005 Spectra Vision Productions, Inc.

Page 2 Fiberlink® 3370 Series User’s Manual
Fiberlink® 3370 Series
Contents
Welcome .................................................................3
Features ..................................................................3
Package Contents .........................................................3
Technical Specications
Model Part Number Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General Specications ................................................4
Transmitter Specications ............................................5
Receiver Specications ...............................................6
Operating Loss Budgets ..............................................7
Maximum Useable Distance ..........................................7
Alarm Switch Settings .....................................................8
Installation Instructions ...................................................8
Data Conguration (Box Version) .........................................10
Baud Rate Settings ..................................................11
Ethernet Settings ....................................................12
RS-Type Data Settings ...............................................12
Data Wiring .........................................................13
Data Conguration (Card Version) ........................................14
Baud Rate Settings ..................................................15
Ethernet Settings ....................................................16
RS-Type Data Settings ...............................................16
Data Wiring .........................................................17
Indicator LEDs ...........................................................18
Operating Pointers .......................................................20
Troubleshooting .........................................................20
Maintenance and Repairs ................................................21
Certications ............................................................21
Warranty ................................................................22
Accessories and Related Products ........................................23
Contents

Page 3Fiberlink® 3370 Series User’s Manual
Fiberlink® 3370 Series
Welcome
Thank you for purchasing Communications Specialties, Inc.’s Fiberlink® 3370 Series. The
3370 Series is used to transmit 3G/HD/SD-SDI over one single mode ber or two multimode
bers as well as 10/100 Ethernet and two channels of RS-Type data. The Fiberlink 3370
series is compatible with single mode or multimode ber. The system delivers noise-free
transmission that retains all of the signals’ initial parameters, regardless of ber optic cable
attenuation. The 3370 Series also provides immunity to video pathological signals over the
entire link budget and operating temperature range.
Features
• Transmit up to 2 channels of bi-directional RS-Type data.
• Transmit 10/100 Base-T Ethernet
• All data and ethernet channels available simultaneously
• SDI signal is equalized and re-clocked prior to ber optic transmission
• Receiver features a re-clocked SDI output
• Immunity to pathological patterns over entire link budget and operating
temperature range
• Compliant with SMPTE 259M-2006, 292-2006, 424M-2006, 276M
• Supports one single mode ber or two multimode bers
• Supports 3G/HD/SD-SDI inputs with or without embedded audio and data
• 14 dB Optical Link Budget @ 2.97 Gbps
• Wide operating temperature range: -10º C to +50º C
• Available in Box and Card versions
• ST or LC connectors available
• Designed and Manufactured in the USA by CSI
Package Contents
• One Fiberlink® Unit (3370, 3371, 3372 or 3373)
• This User’s Manual
• One Ethernet Crossover Cable
Welcome | Features | Package Contents

Page 4 Fiberlink® 3370 Series User’s Manual
Fiberlink® 3370 Series
Model Part Number Specication
Unit Type Part Number
Transmitter Box (1 Fiber, SM) 3370-B7L (LC) 3370-B7S (ST)
Transmitter Rack Card (1 Fiber, SM) 3370-C7L (LC) 3370-C7S (ST)
Receiver Box (1 Fiber, SM) 3371-B7L (LC) 3371-B7S (ST)
Receiver Rack Card (1 Fiber SM) 3371-C7L (LC) 3371-C7S (ST)
Transmitter Box (2 Fiber, MM) 3372-B7L (LC) 3372-B7S (ST)
Transmitter Rack Card (2 Fiber, MM) 3372-C7L (LC) 3372-C7S (ST)
Receiver Box (2 Fiber, MM) 3373-B7L (LC) 3373-B7S (ST)
Receiver Rack Card (2 Fiber MM) 3373-C7L (LC) 3373-C7S (ST)
General Specications
Indicators
Power, Data Rate lock
(3G, HD, SD), Alarm (card version only),
RS-Data Channel 1, RS-Data Channel 2
& Ethernet LEDs on RJ-45 Connector
Box Version Dimensions 6.5 W x 1.15 H x 8 L (inches)
165 W x 29 H x 203 L (mm)
Weight approx. 1 lb.; 0.45 kg
Number of slots in 6000A card cage 2
Power 9-24 volts, AC or DC
3370: 4.8 watts, 16.4 BTU/Hr
3371: 4.65 watt s, 15.87 BTU/Hr
Operating Temperature -10ºC to +50ºC
MTBF 36,000 Hours
Data Specications:
Data Channels 2 Channels, Bi-Directional
Data Bandwidth DC to 115 Kb/sec, max.
Control Format Switch selectable RS-232, RS-422
& RS-485 (4 wire or 2 wire);
Protocols NRZ, NRZI, RZ, Manchester, Bi-phase
Signal Connectors: Removable terminal block Data
Technical Specications
Technical Specications

Page 5Fiberlink® 3370 Series User’s Manual
Fiberlink® 3370 Series
Ethernet Specications:
Port: 10/100 Base-T, RJ-45 connector,
Congured as MDI
Speed: 10 Mbps & 100 Mbps Ethernet,
Switch Selectable
Fiberlink 3370 Transmitter Specications:
Serial Video BNC Input Specications
Channels 2 Channels, Bi-Directional
Data Bandwidth DC to 115 Kb/sec, max.
Control Format Switch selectable RS-232, RS-422
& RS-485 (4 wire or 2 wire);
Protocols NRZ, NRZI, RZ, Manchester, Bi-phase
Signal Connectors: Removable terminal block
Gbps and 350m at 270 Mbps
Return Loss >10dB up to 2.97 Gbps
Fiber Optic Output Specications
Connector LC or ST
Wavelengths Used 1310nm, 1490nm, 1550nm
Emmiter Type FP Laser
Output Power (nominal) -4.5 dBm
SDI Re-clocking At 270 Mbps, 1.485 Gbps & 2.97 Gbps
Technical Specications
Technical Specications

Page 6 Fiberlink® 3370 Series User’s Manual
Fiberlink® 3370 Series
Fiberlink 3371 Receiver Specications:
Fiber Optic Input Specications
Connector LC or ST
Wavelength 1100 - 1620 nm
Minimum Input Sensitivity -17 dBm at 2.97 Gbps;
-22 dBm at 1.485 Gbps
-24 dBm at 270 Mbps;
Maximum Input Power 0 dBm
Serial Video BNC Output Specications
Number of Outputs 1
Signal Level 800mV ± 10%
DC Oset 0V ± 0.5V
Rise/Fall Time < 135 ps at 2.97 Gbps per SMPTE 424M;
< 270 ps at 1.485 Gbps per SMPTE 292;
0.4 ns to 1.5 ns at 270 Mbps
per SMPTE 259M
Overshoot < 10% of amplitude
Timing Jitter < 0.2 UI at 270 Mbps; < 1.0 UI at
1.485 Gbps; < 2.0 UI at 2.97 Gbps
with color bar signal
Alignment Jitter < 0.2 UI at 270 Mbps; < 0.2 UI at
1.485 Gbps; < 0.3 UI at 2.97 Gbps
with color bar signal
Re-clocking At 270 Mbps, 1.485 Gbps & 2.97 Gb
Technical Specications
Technical Specications

Page 7Fiberlink® 3370 Series User’s Manual
Fiberlink® 3370 Series
Fiberlink 3371 Receiver Specications:
Operating Loss Budget
Single Mode Fiber 0-14 dB at 2.97 Gbps
0-17 dB at 1.485 Gbps
0-20 dB at 270 Mbps
Multimode Fiber (62.5u) 0-14 dB at 2.97 Gbps
0-17 dB at 1.485 Gbps
0-20 dB at 270 Mbps
Multimode Fiber (50u) 0-14 dB at 2.97 Gbps
0-17 dB at 1.485 Gbps
0-20 dB at 270 Mbps
Maximum Useable Distance*
Single Mode Fiber 30 km at 2.97 Gbps
48 km at 1.485 Gbps
50 km at 270 Mbps
Multimode Fiber (62.5u) 0.8 km at 2.97 Gbps
1 km at 1.485 Gbps
2.5 km at 270 Mbps
Multimode Fiber (50u) 1 km at 2.97 Gbps
1.3 km at 1.485 Gbps
3 km at 270 Mbps
*Distance specications are approximate, based upon connecting a 3370 Transmitter to a 3370 Receiver, and are not guaranteed.
CSI cannot estimate or guarantee operating loss budgets when the 3370 Series is used with other, non-Fiberlink devices.
Operating loss budget must not be exce
Operating Loss Budget | Maximum Useable Distance

Page 8 Fiberlink® 3370 Series User’s Manual
Fiberlink® 3370 Series
Installation Instructions
The Fiberlink® 3370 Series of ber optic transmission systems are ready for
immediate use and do not require any special tools or equipment.
The following instructions describe the typical installation procedure:
1) Connect the video source to the video input BNC connector on the transmitter unit.
2) (Optional) Connect your data connections as described in the Data Wiring
section of this manual.
3) Connect the video output cable to the video output BNC connectors on the
receiver unit.
4) (Optional) The ethernet port is congured as an MDI port. If you are not connecting
the 3370 Series to an auto-crossover ethernet port, you may need to use the ethernet
crossover cable supplied with the unit to connect to another MDI port.
5) (Optional) Connect your data connections as described in the Data Wiring
section of this manual.
Alarm Switch Settings | Installation Instructions
Alarm Switch Settings for the Transmitter Card
Switch Position Alarm Indication On O
1 Loss of Input Video Enabled Disabled
2 N/A N/A N/A
Alarm Switch Settings for the Receiver Card
Switch Position Alarm Indication On O
1 Loss of Optical Signal Enabled Disabled
2 N/A N/A N/A
Alarm Switch Settings & Options
The Rack Card version of this product has an additional red indicator LED that illuminates
when an alarm condition exists.
The rack card unit also provides an output to drive a model 6020A Alarm Sensing Module
which provides an audible tone and activates a set of contacts for external signaling
purposes.

Page 9Fiberlink® 3370 Series User’s Manual
Fiberlink® 3370 Series
Installation Instructions (cont.)
6) Connect the ber optic cable(s) to the transmitter and receiver units.
Note: when using two ber version, you must connect the transmitters Optical A to
the receivers Optical A and the transmitters Optical B to the receivers Optical B.
7) Connect the Universal Power Supply to the transmitter and receiver units.
For box versions using DC power, please refer to gure 1.
8) Congure your data preferences as described in the Data Conguration
section of this manual.
9) When power is applied, the green POWER LED should illuminate, indicating the
presence of operating power. The 3G/HD/SD RATE LED and the audio LEDs will
give an indication as described in the Indicator LED’s and Alarm Circuitry section
of this manual.
10) The system should now be operational.
Note: The Rack Card version has an additional red LED for indicating the presence of an alarm
condition (loss of signal). Refer to Indicator LED’s and Alarm Circuitry sections of this manual.
Installation Instructions
The transmitting element in the Fiberlink® 3370 transmitter
unit contains a solid state Laser Diode located in the optical
connector. This device emits invisible infrared electromag-
netic radiation which can be harmful to human eyes. The
radiation from this optical connector, if viewed at close
range with no ber optic cable connected to the optical
connector, may be sucient intensity to cause
instantaneous damage to the retina of the eye. Direct
viewing of this radiation should be avoided at all times!
Figure 1:
Power Connector
DC Input Polarity
9-24 Volts
AC or DC
(+) Positive
( - ) Negative

Page 10 Fiberlink® 3370 Series User’s Manual
Fiberlink® 3370 Series Data Conguration (Box Version)
Data Conguration (Box Version):
The Fiberlink 3370 Series box units have two dip switch panels, one with 10 switches, one
with 9. The rst panel, “Data Cong A”, represents the Ethernet and RS Channel A
conguration. The second panel, “Data Cong B”, represents RS Channel B conguration.
Note that all data channels are available simultaneously.
E123456789
DATA CONFIG A
Data Mode
Baud Rate
2 Wire/4 Wire Mode
Termination (Input 120 Ohm)
Termination (Output 120 Ohm)
Ethernet
Data Mode
Baud Rate
2 Wire/4 Wire Mode
Termination (Input 120 Ohm)
Termination (Output 120 Ohm)
123456789
DATA CONFIG B
Este manual sirve para los siguientes modelos
18
Tabla de contenidos
Otros manuales de Receptor de Artel