Arexx BS-1200 Manual de usuario

- 1 -
BS-1200
©AREXX - HOLLAND V0613
MANUAL BS-1200 WIFI
MULTILOGGER WIFI RECEIVER

- 2 -
AREXX and BS1200 multilogger are registered trademarks of AREXX Engineering - HOLLAND.
© English translation (March 2013): AREXX Engineering (NL).
This manual is protected by laws of Copyright. Any full or partial reproduction of the contents are forbidden with-
out prior written authorization by the European importer. :
AREXX Engineering - Zwolle (NL).
Manufacturer and distributor cannot be held responible for any damage resulting from mishandling, mounting
mistakes or disrespect of the instructions contained in the manual.
Subject to changes without prior notice.
More information and technical help see;
WWW.AREXX.COM
&
www.multilogger.nl
Manufacturerd for:
AREXX Engineering
© AREXX Engineering and Havinga Software
1. Product description BS-1200 5
2. Hardware 6
3. First network connection 7
4. BS-1200 webserver 10
APENDIX
A. Firmware upgrade 21
B. Battery replacement 21
C. Safety regulations 22
Table of Contents

- 3 -
Impressum
©2013 AREXX Engineering
Nervistraat 16
8013 RS Zwolle
The Netherlands
Tel.: +31 (0) 38 454 2028
Fax.: +31 (0) 38 452 4482
E-Mail: [email protected]
This manual is protected by laws of Copyright. Any full or partial
reproduction of the contents are forbidden without prior
written authorization by the European importer.
Product specications and delivery contents are subject to chan-
ges. The manual is subject to changes without prior notice.
You can nd free updates of this manual on
http://www.arexx.com/
“BS-1200 and Multilogger” are registered trademarks of AREXX Engineering.
All other trademarks are the property of their owners. We are not responsible for the
contents of external web pages that are mentioned in this manual!
Information about limited warranty and responsibility
The warranty granted by AREXX Engineering is limited to the replacement or repair of the
BS-1200 and its accessories within the legal warranty period if the default has arisen from
production errors such as mechanical damage or missing or wrong assembly of electronic
components except for all components that are connected via plugs/sockets.
The warranty does not apply directly or indirectly to damages due to the use of the BS-1200.
This excludes claims that fall under the legal prescription of product responsibility.
The warranty does not apply in case of irreversible changes (such as soldering of other com-
ponents, drilling of holes, etc.) of the BS-1200 or its accessories or if the BS-1200 is
damaged due to the disrespect of this manual.
The warranty is not applicable in case of disrespect of this manual! In addition, AREXX
Engineering is not responsible for damages of all kinds resulting from the disrespect of this
manual! Please adhere above all to the „Safety recommendations“ in the BS-1200 manual.
Please note the relevant license agreements on the CD-ROM!
IMPORTANT
Prior to using this BS-1200 receiver for the rst time, please read this manua thoroughly up
to the end. it explains the correct use and inform you about potential dangers. Moreover it
contains important information that might not be obvious for all users.
Important safety recommendation
This module is equipped with highly sensitive components. Electronic components are
very sensitive to static electricity discharge. Only touch the module by the edges and avoid
direct contact with the components on the circuit board.

- 4 -
Symbols
This manual provides the following symbols:
The “Attention!” Symbol is used to mark important details.
Neglecting these precautions may damage or destroy the
module and/or additional components and additionally you
may risk your own health or the health of other persons!
The “Information” Symbol is used to mark useful tips and
tricks or background information. In this case the information
is to be considered as “useful, but not necessary”.
Safety recommendations
- Check the polarity of the power supply.
- Keep all products dry, when the product gets wet remove the power directly.
- Remove the power when you are not using the product for a longer period.
- Before taking the module into operation, always check it and its cables for damage.
- If you have reason to believe that the device can no longer be operated safely,
disconnect it immediately and make sure it is not unintentionally operated.
- Consult an expert if you are unsure about the function, safety or connection to the module.
- Do not operate the module in unfavourable conditions.
- This module is equipped with highly sensitive components. Electronic components are
very sensitive to static electricity discharge. Only touch the module by the edges and avoid
direct contact with the components on the circuit board.
Normal use
This product was developed as an WIFi receiver for the AREXX Multilogger system. It will only
work together with other AREXX Multilogger sensors and products.
It may be used indoors only. The product must not get damped or wet. Also be careful with
condense when you take it from a cold to an warm room, give it time to adapt to the new
conditions before you use it.
Any use other than that described above can lead to damage to the product and may
involve additional risks such as short circuits, re, electrical shock etc.
Please read all the safety instructions of this manual.

- 5 -
1. PRODUCT DESCRIPTION BS1200
The BS1200 is a WIFI receiver station for the AREXX Multilogger system.
Like the BS510 USB and BS1000 Lan receivers, the BS1200 receives AREXX
sensor data via wireless transmission and sends these data via a WIFI
Network interface to a PC.
The WIFI link enables the BS1200 to send measured values wirelessly via the
TCP/IP protocol. This interface allows the transmission of Messenger
e-mails and HTTP requests as well. In addition to that, the built-in web
server can display recent measurement values. You will have wireless WIFI
access to this built-in web server with all other network items like a (Laptop)
PC, smartphones and tablets.
Contents of the package:
- BS-1200 WIFI multilogger receiver
- Power supply
- USB cable
- CD-ROM with all the necessary Software and manuals
* The right of return does not apply after opening the plastic bags containing parts and components.
* Read the manual thoroughly prior to mounting the unit.
* Be careful when handling tools.
* Do not assemble any items in presence of small children. They can get hurt with the tools
or swallow small components and parts.
* If the BS1200 gets wet, remove the power and dry all parts as thoroughly as possible.
* Remove the power if the BS1200 will not be used for more than one week.
Warnings

- 6 -
1.2. Specications:
- Power supply : 5V DC
- Consumption : Approx.. 500 mA
- Dimensions: (LxWxH) : 220x165x45 mm
- WIFI transceiver
- USB connector
2. HARDWARE
1. ON/OFF switch A. USB connector
2. Red LED B. DC connector
3. Blue LED
4. Green LED
2.1. Front and back panel
On the front of the BS-1200 the on/off switch and three LEDs are pos-
sitioned.
The function of the LEDs is:
Red LED is on when the BS-1200 is on.
Blue LED Flashes when the BS-1200 receives data from the sensors
Green LED
- Off: network and ash memory inactive
- On: network inactive, active ash storage,
- Flashing; short on and long out: active network, no ash storage
- Flashing; long on and briey out: active network, active ash storage
2 1 3 4
A B
Fig.1. Top
Fig.2. Back

- 7 -
2.2. Getting Started
The BS-1200 comes with an adapter and USB cable. The adapter connects
to the back 5V/±500mA. The USB cable can be used to connect to the
BS-1200 directly to a PC, then BS-1200 will operates exactly the same as a
BS510 receiver.
You can also use the USB cable to ash the new rmware for a new soft-
ware update.
3. First network connection
This paragraph describes how to connect the BS-1200 to your local Wi
network. For this we need the networkcong tool which can be found in the
tools menu of the logger software (be sure you have the latest version).
2.1. General settings
The BS1200 factory setting for Wi is:
security: none
ssid: ssid
Normally, you won’t have these settings, so we have to adjust the BS1200
to match your local Wi settings. The settings can be set with the network-
cong tool; you can start it from the ‘tools’ menu of the temperature logger
software.
In short, you scan for a network, select it and set its passphrase. After
pressing the write button a connection will made by the BS1200.
Connect the BS1200 via usb to a pc with the latest temperature logger soft-
ware. Start the networkcong tool; the following dialog will be displayed:
It shows empty network settings.
When you press the read button, you obtain
the current status of the bs1200.
You will nd the bs1200 is trying to connect
(to the ‘ssid’ network), but a timeout is
given since the attempt fails.
Fig.3. Networkcong tool

- 8 -
Note that some extra elds are displayed now concerning the Wi-connection.
(The tool detected that a Wi-enabled module is accessed).
Now we can scan for networks using the ‘scan’ button.
The status line will show the scan started, and after some seconds when the
scan has nished. The SSID eld is a combobox that will show a list with
available networks, including the current ssid (‘ssid’ for now).
Fig.4. Networkcong tool
extra elds
Fig.5. Networkcong tool
Finished scan

- 9 -
Now the new info is saved in the BS1200 and it will initiate a new connection.
As indicated on the screen we switch back to the ‘Read’ tab and click on the
‘Read’ button again.
When the module is connected, it shows ‘Wi status: Connected’, and on top
the message ‘Network conguration valid’.
The obtained ipaddress and network name can be found on the display.
Normally, you can use the networkname in the url eld of your browser to
access the bs1200. (Please prepend ‘http://’ before the networkname). If that
is not working, the bs1200 should also be accessible by its ip address.
Fig.5. Networkcong tool
write
Fig.6. Networkcong tool
read

- 10 -
4. BS-1200 WEBSERVER
The obtained ipaddress and network name with the Networkcongtool can
be used to get access to the BS1200 webserver.
Normally, you can use the networkname in the url eld of your browser to
access the BS1200. (Please prepend ‘http://’ before the networkname). If
that is not working, the BS1200 should also be accessible by its ip address.
The embedded Web server contains several pages with recent data. There is
an administrative section available for various settings.
The BS1200 web server can be found at the address given by the network
name. Make sure that any rewall and/or browser blockades are removed
which are applicable to the BS1200.
The webbrowser start page shows for each sensor the most recent measu-
rement (Fig.7). The value presented is the latest sensor measurement. The
time display is formatted according to the default settings on the computer.
The RSSI column gives an indication of the strength of the received radio
signal.
Fig.7. Webbrowser
Tabla de contenidos
Otros manuales de Receptor de Arexx