Aquavolta Cavendish 2.0 Instrucciones de uso

Owner’s Operation Manual
Alkaline Water Ionizer
SM-S112TL
Warning: Incorrect installation and/or operation
could void your valuable warranty
Please protect your investment!
READ THIS
MANUAL CAREFULLY
O
A
W
co
Pl
MA

02
Table of contents
Safety Precautions
Names And Functions
How to Use
Replacing Your Filter
Composition of Filter
How to measure pH
Counter Top Installation Instructions
Installation Instructions
Trouble Shooting Guide
Product Specifications
Name and functions of parts
Accessories(Needed for faucet installation)
How to install the faucet
How to use
Product Specifications
WARRANTY CARD
24/25
26
27/29
30/33
34
35
03/04
05/06
07/12
13/14
15
16
17
18/20
21/22
23
SM-H112TL
IO-600U

Safety precautions
If your machine becomes submerged in water, unplug the power cord from the wall
before removing your machine from the water.
This may result in electric SHOCK!
DO NOT USE your machine at voltages other than specified.
DO NOT PLUG in your machine where it will exceed the rating of outlet or electric wiring.
Failure to do so can result in fire, injury and / or damage to yourself, or wiring or machine!
NEVER touch the power cord or plug with wet hands
- This may result in electric SHOCK!
Ensure the power plug is firmly and properly inserted into the outlet
- This may result in electric SHOCK or FIRE!
DO NOT attempt to repair or service the machine yourself!
Make sure to use your machine only with potable water suitable for human consumption.
DO NOT run hot water through your machine.
DO NOT clean by pouring water over or spraying the machine.
Unplug your machine if you plan Not to use it for an extended period of time or turn
off the master power switch on the back of the unit.
Filter replacement may be necessary
03
Read the recommendations below before installing the ionizer
DO NOT MAKE A REPAIR YOURSELF! Attempting to do so will VOID your warranty!
Contact service center if the machine breaks down.
Protect your machine from freezing temperatures and direct sunlight.
Acidic water tubing must not be raised higher than the base of the product.

DO NOT close, bend, pinch, press or otherwise obstruct output ports or hoses.
If the appliance makes strange or unusual noises.If burning smells are detected,
unplug the power cord immediately and contact customer service
pH reagent liquid precautions
Some helpful tips
DO NOT expose the pH measuring reagent to extreme heat, flames or fire.
It is Combustible.
DO NOT store alkaline water in stainless steel, bronze or aluminum
containers. Glass or ceramic is best for storing your alkaline water, but you can
use high quality plastic container also.
Always try and keep your stored water cool and away from direct sunlight.
It is always best fresh out of the machine and ideal if consumed on a day to-day basis.
Save the box and Styrofoam your machine came packed in.
This will help if your machine needs to be transported at a later date.
If you are using your machine downstream of a reverse osmosis system or running
reverse osmosis water in your home, re-mineralization of the water will be needed.
Neither drink the pH reagent liquid, nor put it in the eyes or apply to the body.
If the liquid is ingested, induce vomiting immediately and call a doctor.
If the liquid gets in the eyes, flush immediately and thoroughly with cool water;
call a doctor.
If spilled or dropped on your body, wash if off immediately.
04
A / S
Within 1M, do not use the outlet hose to be longer than 1M
Make sure to keep the pH reagent liquid tightly closed and out of the reach of children.

Names and functions
05
Front
Rear
Body
Function display panel
Flexible stainless
steel alkaline water
outlet.
Function button
Filter Cover
Power switch
Fuse holder
Acidic water
discharging hole
Water supplying hole
A/C power cord

06
Indicators / Controls
Displaying filter lifespan
Indicating total amount of filter use
Alkaline selection button
Button which is used when function of alkaline
water is selected
Setting display
Method to use lamp which is on when each
function is selected
Water purification button
Button which is used when function of water
purification is selected
Acidic selection button
Button which is used when function of acidic
water is selected
Power button
Button which is used when on/off
Setting button
Button which sets each function
Voice button (muting voice sound)
Function that can make voice sound on/off which
is made when each function is selected
Displaying water discharging time
Indicating time during which water is discharged
Displaying number of grade in use
Indicating number of grade in alkaline/acid and
purification currently in use
Displaying pH
Indicating pH for each grade
Displaying volume of supplied water
Indicating total water flow per minute
Alkaline2
pH
Filter
Flow
Running Time
9 .0
3888
1.6
00:00:14

NOTE
07
Initial operation
The water may initially come out discolored (light to charcoal gray) due to carbon
particulates in the new filter.
This is not harmful and is typical of all carbon filters. Allow the water to flow
for 2-3 minutes in the "Filtered" mode to flush all the carbon dust.
Power up your ionizer.
Turn on power switch on back side
after plugging power code into socket.
1
2
Start water flow through your ionizer.
- Press the
"POWER"
button which opens the internal valve in your ionizer.
- The Digital Filter Life Indicator will begin and you will hear your ionizer's "voice"
announcing the selected mode of operation.
How to use
OFF
ON
Signal sounds, initial screen appears and disappear
again which makes it stand-by status.
Alkaline2
pH
Filter
Flow
Running Time
9 .0
3888
1.6
00:00:14
er
r
3
38
38
8
88
88
k
te

08
NOTE
If alkaline water function is set previously, alkaline water used in previous step is
discharged
When drinking alkaline water
2
When pressing
"ALKALINE "
water selection
button, graphic lamp is on which
indicates character of alkaline water,
number of grade, and announcement
can be heard which informs
alkaline water grade.
Repeat steps 1-3 above, or with water already running through the machine then:
1
How to stop
12 3412 34
Alkaline2
pH
Filter
Flow
Running Time
9 .0
3888
1.6
00:00:14
e
e
e
2
2
2
2
e
Whenever you press alkaline
water selection button
repeatedly, it changes
number of grade.
Press the
"POWER "
button, water supply is
stopped and it is converted to
stand-by status automatically.
Stand-by mode status

09
NOTE
If acidic water function is set previously, alkaline water used in previous step is
discharged
When using acidic water
※This function is necessary when getting a lot of acidic water and using it for washing face or body.
※Acidic water is not drinking water. Be careful not to drink acidic water, confusing it with
alkaline water.
Repeat steps 1-3 above, or with water already running through the machine then:
1
2
When pressing
"ACIDIC"
water selection
button, graphic lamp is on which
indicates character of acidic water,
number of grade, and announcement
can be heard which informs
acidic water grade.
Whenever you press acidic
repeatedly, it changes
number of grade.
How to stop
Press the power button, water supply is
stopped and it is converted to
stand-by status automatically.
Stand-by mode status
12 3412 34
Acidic2
pH
Filter
Flow
Running Time
5 .8
3888
1.6
00:00:14
c
c
2
2
2
2
c

NOTE
If filtered water function is set previously, filtered used in previous step is
discharged
10
When drinking purified water
Repeat steps 1-3 above, or with water already running through the machine then:
1
2
When pressing
"FILTERED"
water selection button, graphic lamp is on which
indicates character of filtered water, number of grade, and announcement
can be heard which informs filtered water grade.
How to stop
Press the power button, water supply is
stopped and it is converted to
stand-by status automatically.
Stand-by mode status
Filtered
pH
Filter
Flow
Running Time
7 .0
3888
1.6
00:00:14
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Ionizador de aire de Aquavolta
Manuales populares de Ionizador de aire de otras marcas

Static Clean
Static Clean 4203UC Manual de usuario

SCS
SCS 960 Manual de usuario

Desco EMIT
Desco EMIT C/E Series Manual de usuario

Best Living Systems
Best Living Systems KHAOS Manual de usuario

SCS
SCS 963E Manual de usuario

Desco EMIT
Desco EMIT Chargebuster 50680 Instrucciones de instalación y funcionamiento

Terra Universal
Terra Universal IonBar Guía de instalación

Phonocar
Phonocar 04971 Manual de usuario

Klarstein
Klarstein ST. OBERHOLZ OFFICE Manual de usuario

Life Ionizers
Life Ionizers Fuzion Manual de usuario

ITW
ITW Simco-Ion IQ Power Fantom Manual de usuario

LIFE Ionizer
LIFE Ionizer M7 X NG Manual de usuario