Congratulations on the purchase of your new alkaline mineral water
ionizer. We are grateful to our many customers for recognizing our
eorts in providing the best water ionizer available!
Ionized Alkaline Mineral Water promotes good health with its superi-
or hydration, mineralization, oxygenation and cellular detoxication.
Our ionizers use a series of internal and external ltration systems
and the nest-quality platinum-coated titanium plates, to create
alkaline water with the highest anti-oxidant potential in the industry.
Welcome to the LIFE Ionizers family!
What do I need to know?
• Please read all safety warnings before the installation or
operation of your LIFE Ionizer to ensure proper product usage.
• To receive warranty service, you must register your warranty
online. Please see enclosed warranty card for detailed instructions.
• Refer to this manual when you have questions on adjustments
and how to change your lters. We also have instructional videos
and help guides online at LifeIonizers.com/support.
• Filters are important! To ensure optimal performance and to
guarantee your warranty, internal lters should be changed
annually and a citric acid cleaning lter should be used up to
three times per year to reduce the build-up of minerals found
in the source water which can cause blockage in the ionizer.

3
LIFE | M7 X/M7 X UC NGLifeIonizers.com/support
Safety Guide
Product Specications
Package Contents
Important to Remember
Parts of the Ionizer
M7 X NG Installation (counter top)
M7 X NG UC Installation (under counter)
Quick Connect Fittings and Tubing
Display Overview
Function Options
M7 X NG Operation Method (counter top)
M7 X NG UC Operation Method (under counter)
Internal Filter Replacement
Filter Reset Instructions (counter top)
Filter Reset Instructions (under counter)
Citric Acid (Scaling) Cleaning Filter
Filtration Media
Pre-Filter Replacement
Acidic Cleaning Instructions & Routine Maintenance
Common Problems and Solutions
Operation Warnings/Error Messages
How Alkaline Water is Made
Alkaline/Acidic/Puried Water
Uses of Ionized Alkaline/Acidic Water
Performance Features
Frequently Asked Questions
4
7
8
10
12
14
16
18
19
20
25
26
28
29
30
31
33
34
35
36
37
38
39
40
43
44
Table of Contents

4
LIFE | M7 X/M7 X UC NG LifeIonizers.com/support
Safety Guide
Power Plug
As with most electrical appliances, electrical parts in this
ionizer are electrically live even when the switch is o.
• Power cord should not be touched with wet hands
• Use only (110v) in the USA, Mexico and Japan. Most
other countries require (220v). The power cord cannot
be altered from manufacturer’s specs.
• Do not crimp or staple the power cord
• Power cord should be plugged directly into an
electrical outlet
• Dusty or dirty electrical outlets may cause safety
issues
• Bending, twisting, pulling or putting heavy objects
onto the power word may cause electrical problems
including re.
• If power cord, plug or electrical outlet are damaged,
discontinue use immediately.
• Unplug the electric power when
not in use for a long time (over 3
days)

5
LIFE | M7 X/M7 X UC NGLifeIonizers.com/support
Ionizer
• Place machine in an upright position only
• Do not install this unit in direct sunlight or near a heater,
replace or other heat source
• Do not place the machine in humid areas such as
bathrooms
• If wall mounted, secure rmly and correctly
• Do not use water with a temperature of over 95
degrees Fahrenheit or 35 degrees Celsius
• This machine should not be repaired or otherwise
disassembled by any unauthorized person as it may
cause electrical re or shock and will void the
manufacturer’s warranty
• Do not clean this machine by spraying the ionizer with
water as it may cause electrical shock.
• Do not use benzene, thinner, or chemicals to clean the
unit as it can damage the housing.
• Do not block the unit vent as it can cause overheating
and/or electrical problems.
• Do not block the water passage or tubing
• Do not place anything on the unit
• Don’t shake or drop
the unit
• If the ionizer
machine falls into
water:
1. Unplug power cord
from electrical outlet
2. Wipe the machine
down and place in
shaded area
3. Contact your LIFE
Ionizer dealer

6
LIFE | M7 X/M7 X UC NG LifeIonizers.com/support
Ionized water
• If inexperienced with drinking Ionized Alkaline Water,
users are encouraged to start with level 1
• When drinking Ionized Alkaline Water - Do not take
prescription or other medications for approximately one
hour before and after drinking water. Ionized alkaline
water hydrates more eciently, therefore will deliver
more medication than tap water.
• Store Ionized Alkaline Water in an air-tight glass
container and refrigerate for up to 2 days
• DO NOT DRINK ACIDIC WATER
• Do not store Alkaline or Acidic water in metal containers,
although you can put alkaline water in the Water for LIFE
Stainless Steel bottles as they are designed to maintain
pH and ORP
• Aluminum and brass containers will be tarnished by
alkaline and acidic water
• If not used for several days, run water through the unit
for 1 to 3 minutes before starting
• If the machine will not be
used for several days:
1. Unplug the power cord
from the electrical outlet
2. Turn o the water valve to
avoid leaking
3. Remove lters, drain and
place in refrigerator in
plastic bags.
4. Let water run on the
“Puried Water” setting for
at least 3-5 minutes
before any operation

7
LIFE | M7 X/M7 X UC NGLifeIonizers.com/support
Product Specications
Special features Fully convertible: counter-top to
under counter
Cleaning function Advanced RADC Cleaning System
Display Full Color LED Display w/Automatic
Voice Prompting
Filtration Dual Internal, Custom Pre-lter
Flow Control Automatic
Power in watts Adjusts up to 450 watts
ORP Output up to -700
(Enhanced ORP at drinkable levels)
pH Output pH range from 2.5 up to 11.0
Protection Automatic Heat Sensor
Power System MAX Yield SMPS Power System™
Rated Voltage Dual voltage input compatibility
110/220 volts. All you need is the
power plug or adapter. When
plugged into the power source the
unit automatically recognizes voltage.
Settings 1 Puried, 3 Acidic, 4 Alkaline
Warranty Lifetime Parts plus 10 years labor
Dimensions 13” x 13” ¾ x 6”
Plate Material Platinum over Industrial Titanium

8
LIFE | M7 X/M7 X UC NG LifeIonizers.com/support
Package Contents
Extra Fuse
1/4”Tubing Hose User Manual
BTB Chemical
pH Color
Chart
Reagent Drops
(pH Test Drops)
Suction Cup Located in the Power
Switch at the bottom of the
machine
1
LIFE| M7 X/M7 X UC NGLifeIonizers.com/support
Flexible
Hose
Cold Water
Connect
Faucet
Faucet Adapter
Faucet
Patch Cable
Alkaline/Acid
Hoses
Tubing/Cable
Protector
For M7 X UC NG
Diverter Valve

9
LIFE | M7 X/M7 X UC NGLifeIonizers.com/support
10
9.0
8.0
7.0
6.0
5.0
4.0
Alkaline
Water
Acid
Water
Neutral
PH Tester Kit Instructions:
1. Place 1-2 ounces of water you are
testing into a glass
2. Add 2-3 drops of Reagent Drops
3. Stir water to observe the color
change
4. Compare to “pH COLOR CHART”
to determine pH and acid levels.
When handling the pH test (reagent drops):
1. Keep away from eye area. If eyes become irritated, ush
thoroughly and consult a doctor.
2. If accidentally swallowed, drink water and consult a doctor.
3. Store in an airtight container away from the reach of children.
4. Drops are ammable. Keep away from children.
How to measure the pH of your water
A pH color chart and a bottle of Reagent Drops are included with
your ionizer in case you would like to test the water from your new
ionizer.

10
LIFE | M7 X/M7 X UC NG LifeIonizers.com/support
Important to Remember
• You must run 2-3 gallons of water through the pre-lters before
you connect them to the ionizer. To do this, install the pre-lters
into their housings, connect a piece of tubing to the outlet con-
nection on the pre-lter housing and run it into the sink so you
can ush them out with water. This hydrates the lters and cleans
them from any loose media. After you nish this procedure, con-
nect your pre-lter back to your ionizer and run normally. This
needs to be done every time you put in new pre-lters.
• The pre-lter housings must be replaced every 2 years.
Pre-lter Installation & Maintenance
Ionizer Installation
• Plugs located on the bottom of the ionizer must be removed
before installation.
• Do not overtighten the patch cable connection on the back of
the ionizer when plugging in patch cable.
• Run the ionizer and check for leaks at all tubing locations from
the Diverter Valve to the Ionizer itself before operating the unit.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Manuales populares de Ionizador de aire de otras marcas

Static Clean
Static Clean 4203UC Manual de usuario

SCS
SCS 960 Manual de usuario

Desco EMIT
Desco EMIT C/E Series Manual de usuario

Best Living Systems
Best Living Systems KHAOS Manual de usuario

SCS
SCS 963E Manual de usuario

Desco EMIT
Desco EMIT Chargebuster 50680 Instrucciones de instalación y funcionamiento