AODELAN TR90 Manual de usuario

1
TR90
Remote Switch with Digital Timer
定时快门遥控器
User Manual
使用说明书


1
Thank you for purchasing a
AODELAN product.
AODELAN TR90 is a wired shutter remote
controller with digital timer. It is designed
to trigger a camera shutter at regular timed
intervals and provides delay (time before
shooting starts), exposure time, interval, and
number of shots settings for timed interval
photography. Shutter speed can also be
selected with the camera if desired.
The timer functions can be set from 1
second to 99 hours, 59 minutes, 59 seconds.
The TR90 features a locking two-stage
shutter button, backlight display, status LED,
and beep sound.
Please read this user manual as well as the
user manual provided with your camera
which works with TR90 before use.

2
For Your Safety
To prevent damage to your product or
injury to yourself or to others, read the
following safety precautions in their entirety
before using this equipment. Keep these
safety instructions where all those who use
this equipment will read them.
The consequences that could result from
failure to observe the precautions listed in
this section are indicated by the following
symbol:
This icon marks warnings, information
that should be read before using this
AODELAN product to prevent possible
injury.
Do not disassemble or modify
Failure to observe this precaution
could result in electric shock or product
malfunction. Should the product break
open as the result of a fall or other
accident, remove the batteries and take the
product to a AODELAN-authorized service
representative for inspection.
Keep dry
Do not use in the presence of
flammable gas
Do not handle with wet hands or immerse in
or expose to water or rain. Failure to observe
this precaution could result in fire or electric
shock.
Failure to observe this precaution could
result in explosion or fire.

3
Keep out of reach of children
Do not expose to high
temperatures
Turn off immediately in the
event of malfunction
This device contains small parts which may
pose a choking hazard. Consult a physician
immediately if a child swallows any part of
this device.
Do not leave the device in a closed vehicle
under the sun or in other areas subject to
extremely high temperatures. Failure to
observe this precaution could result in fire
or in damage to the casing or internal parts.
Should you notice smoke or an unusual
smell coming from this device, remove the
battery immediately and take the device to a
AODELAN-authorized service representative
for inspection, taking care to avoid burns.
Continued operation could result in injury.
Observe precaution when
handling batteries
Batteries may leak or explode if improperly
handled. Observe the following precautions
when handling batteries for use in this
device:
• Use only batteries listed in this manual. Do
not mix old and new batteries or batteries of
different types.
• Read and follow all warnings and
instructions provided by the manufacturer.
• Do not short or disassemble.
• Do not expose to flame or excessive heat.

4
• Do not attempt to insert batteries upside
down or backwards.
• Batteries are prone to leakage when
fully discharged. To avoid damage to the
product, be sure to remove the batteries
when leaving the product unattended
for prolonged periods or when no charge
remains.
• Should liquid from the batteries come
into contact with skin or clothing, rinse
immediately with fresh water.

5
Parts of the TR90
Refer to the illustrations
Body
Connector
Cord
Release lamp
Display panel
TIMER START/STOP button
ON/OFF button
SET button
Illuminator/lock button
Selector button
Shutter-release button
Battery-chamber cover
Eyelet for strap (available separately; use
cell phone or other similar strap)
Parts of the TR90
Display Panel
Selection cursor
Timer display
Lock indicator
Low battery indicator
“TIMER ACTIVE” indicator
Speaker on/off indicator
“SET” indicator
“RELEASE” indicator
Number of shots

6
Inserting Batteries
Slide the battery-chamber cover ( ) from
the back of the TR90 and insert two AAA
1.5 V LR03 alkaline batteries (available
separately) as shown.
The TR90 will power on after batteries are
inserted. If not being used please turn
off.
The Low Battery Indicator ( )
The low battery indicator ( ) will blink
when the batteries are low. Ready spare
batteries.
Inserting Batteries
Power on/off:
Power on: Press the TIMER START/STOP
button ( ) for 3 seconds. The display panel
will light up.
Power off: Press the TIMER START/STOP
button ( ) for 3 seconds. The display panel
will go blank when the TR90 shuts powers
off.
Replacing Batteries
When replacing batteries:
1.
Turn the camera and TR90 off and disconnect
the TR90.
2. Remove the batteries.
3. Insert new batteries

7
Parts of the TR90 The Illuminator/Lock Button
Press the illuminator/lock button
( ) briefly to activate the control panel
backlight. The backlight will remain lit for
about six seconds; pressing the selector
button ( ) while the backlight is on
extends the timer for another six seconds. To
lock all controls except the shutter-release
( ) and illuminator/lock buttons, press
the illuminator lock button until the lock
icon( ) is displayed in the control panel.
To release the lock, press the illuminator/
lock button until the lock icon is no longer
displayed.

8
Connecting the TR90
1. Turn the camera and TR90 off.
2. Insert the cable into the camera remote
port.
Using the TR90
The TR90 functions as:
• An automatic timer Choose the delay
(time before shooting starts), exposure time,
interval, and number of shots for timed
interval photography. Shutter speed can be
selected with the camera if desired.
• A manual release Take photographs
manually using the shutter-release button
on the TR90. Photographs can be taken
manually even when the timer is running.
Disconnecting the TR90
Turn the camera and TR90 off and
disconnect the TR90.
Timed Photography
1. Adjust Camera Settings
1.1 Connect the TR90 and turn the camera
on.
1.2 Adjust camera settings as follows (see
the camera manual for details):
* Select “release priority” if available.
Tabla de contenidos