A170, A190, A250, A330 and A400
Instructions for Installation and Use
408020(en)
ANTTI-TEOLLISUUS OY
Koskentie 89
FIN-25340 KANUNKI, Finland
Tel. (02) 7744 700
Fax. (02) 7744 777
1/2005


2
Antti-heaters
1/2005

ANTTI-TEOLLISUUSOY 3
Index
INTRODUCTION ..................................................................................................................... 5
INSTALLATION ....................................................................................................................... 6
1.LiftingtheHeaterinPlace.................................................................................................... 6
2.InstallationofAirandFluePipes.......................................................................................... 7
3.Oil Burner and Pipes ........................................................................................................... 9
4.Electric installation............................................................................................................. 10
Pointstonote before putting the machine intooperation........................................................ 12
OPERATINGINSTRUCTIONSOFTHEHEATER .................................................................. 12
SERVICE.............................................................................................................................. 13
GUARANTEE ....................................................................................................................... 13
DISTURBANCES ................................................................................................................. 14

4
Antti-heaters
1/2005
Read carefully the Installation and Instruction Manual before installation and putting
the machine into operation
Instruction Manual and the Use of the Machine
Thismanual is intended for professionalfarmers.Theuse of the machinerequiresnormalskills
andgeneral knowledge offarming.
Heater Type
Thisbookletgivesinformationon the installation and operation ofA170-A400heaters.
Informationof the type of yourheaterisstamped on the nameplateonthe side of the machine.
To get prompt assistance in the case of operational disturbances, and to simplify ordering of
spareparts always notify thesellerandtheservice personnel of thedatagivenon the name
plate.Tomake this dataavailablewhenever required write it down in the corresponding place in
thepictureprinted on this page.

ANTTI-TEOLLISUUSOY 5
ø200
FAN
FLUEPIPESLEEVE OVERPRESSUREHATCH
TUBES
FURNACE
INTERMEDIATEJACKETS
OUTERJACKETS
AIRDISTRIBUTIONPLATES
WIDTH BURNER WIDTH BURNER
INTRODUCTION
-Theheaterisdesignedforheatingthe dryingair andblowing itunderpressurethroughthehotair
dryer.
-Thedeliveryof theheaterincludes thefanwith electricmotor, thecombustionchamber,the heat
exchangerandtheframe structure.Inconnectionwiththeinstallationthe heaterisequippedwith
the oil burner, thermostats and piping.The required electric cabling is connected in the electric
centre. In addition to this is required a tank for light-oil and a pipeline from the oil tank to the
burner, whichfulfils thevalidregulations.
-Thenoiseemissionby heater type in the heater room is:
A170 86 dB
A190 85 dB A250 91 dB
A330 91 dB A400 92 dB
NOTE! Always use hearing protectors when entering the heater room when the
heater is in operation!
-Dimensionsof the heaters:
Note!:The heatersareavailablefor both rightand left-handedfan and burnerinstallations.
-Structureof theheater:

6
Antti-heaters
1/2005
Thesuction air for theheatermustnotbe taken from insidetheheaterroom but through a
specialpipewhichisledfromthesuctionopeningoftheheaterfantotheoutsideair.
Two (2) openings of at least 600 cm² in size both fitted withasafetynetmustbefurnishedfor
thecombustion air and theventilationofthe burner.One of theopeningsmustbe located in the
upperpartof the heater room and theotheroneinthe lower part of the heaterroom.
Theheaterroomof a heater which burns more than 30 kg/hofoilmustbeequippedwith forced
ventilationworking on the overpressureprinciple(theprefabricated, steel elementheaterrooms
doesnot require aventilationfan).
OilTank
Itisadvisable to installthestandardoiltankon a concrete slab.Atankwith maximum volume of
15 mm³ may be located at a distance of 1 m from the building. The tank can also be located in
aseparate bunker.Consult the localmunicipal authorities forvalidregulations.
Theoil tank mustbeinstalled approximately onthesame level withtheheater (maximum
permissibleheight difference is ±3.5 m).
Consultthe municipal authoritiesforregulations concerning largeroiltanks.
1.LiftingtheHeaterinplace
-Note whenliftingthe heater:
-That all lugs intheheaterare in use.
-Makesure that the lifting gear will remain inpositioninthelugs.
-Only useliftingmachineswith sufficientpower.
-Nevergounderor too near the heater to be lifted.
-Weights of the heaters: Type Weightkg Type Weightkg
A250 530
A170 380 A330 575
A190 465 A400 690
-Theheaterwithout theburnerisliftedinplacein accordancewiththeinstallationdrawingorplan.
Because the foundation has to be level and steady, there is no need to attach the heater to its
bed.
INSTALLATION
The installation of the heater requires an authorised professional electrician and an oil burner
expert,aswell as a person whoisfamiliarwith the installationof dryer machinery.
The heater must be placed in a room which meets the regulationsA:47 issued by the Rescue
Departmentofthe Ministryof InternalAffairs;or,covered fromtherain,atadistanceofat leastfour
(4)metres from the dryerbuildingandother buildings.
Whenchoosing the location for the heaterhas to betaken intoaccount thatthe intakeair for the
heater and the burner has to be clean. The air intake of the heater and the oulet air pipes of the
dryingmachinerymustbe placed on the opposite sides of the building.
Note! Waste in suction air is a fire hazard!

ANTTI-TEOLLISUUSOY 7
2. InstallationofAirandFluePipes
- Theairpiping between the heaterand thedryeris installedbyusing Antti airpipe parts
(D630 mm).Note!: The airflowregulatoris notinstalled inthese pipes- itbelongs to the
suctionpiping oftheheater.Theairchannelhasto be installedsothatloose grain and waste
willnot slide directlyintotheheaterfromtheendofthedryingsection. Thisconcernsdryerswith
diagonal,conical air inlet ends.Particularlywhenfillinganemptydryer,some grainsmayfirstfly
intotheairpipingandfurtherintotheheater.Toavoidthis,theairpiping mustnotbeinclined
allthewaytotheheaterbutitmusthaveasufficientlylonghorizontalpart.Thehorizontalpart
shouldbeslightlyinclinedtowardsthe dryer..If thepipelineisshort,itispossibletouse
protectionnetsattheendsoftheinletairchannels.SeeInstallationandOperationManualfor
Antti-dryers
- Makesurebeforeinstallationofthepipesthatthere are no foreign particles inside the
heater!
-. Antti-teollisuussupplies as standard a grainpocketfordryers with more than threetop
sectionsandadiagonal(conical) air inlet. The grain pocket shall be installed in the
connectingpipebetween the dryer and theheater.As necessary the grain pocketmustbe
emptied of gathered grains. So its filling grade must be observed. See illustration
“Installation of the grain pocket to the air piping” for the correct installation practise.
WARNING! Foreign particles inside the heater are a fire hazard!
Install the grain pocket to the horizontal part of the
air pipe, where it operates efficiently, See
illustration
Lift the part close to the pipe and attach it properly
using the ties. Working inside the part, draw a
cutting line using a felt-tip pen, take away the part
and use a handheld profiling machine or plate
shears for cutting the opening.
Lift the part back in place and tie it to the pipe
using the ties. Attach the part to the pipe with self-
tapping screws or rivets. Finish with sealing
mastic. Close the outlet sleeve of the pipe of the
grain pocket with a plug and, as required, secure
that it stays in position using self-tapping screws
Installation of the grain pocket to the piping:
1m 1m
DIAGONALAIRINLET
GRAINPOCKET
POSITIVEPRESSREHEATER

8
Antti-heaters
1/2005
501018
501017 x4
fourø9 holes aredrilled during
assembly
AIR DISPERSION PLATE (not used in
dyers with diagonal end)
Air dispersion
plate
Drying air pipe
Protective net Suction air pipe
Air-flow regulator
- Leadtheinlet air pipe from the suctionopening of the fanto the outside air. The air pipe(L=
0.23 m) withthe airflow regulator, is installedin the inletpipe in a placewhere it is easyto
use. The protectivenetis installedinthe endof thepipe (tobe disconnectedfrom the
heater).
- Theminimumheightfromthegroundtotheinletairopeninginthewalloftheheaterroomis
one(1)metre.
- When it´israining the efficiencyof the heateris betterif the inletopening isequipped witha
raincover.
-The inlet pipe from the heater can normally be led to the lowermost drying section. If the
air channel ends are straight, we recommend to use in front of the outlet air pipe sleeve
dispersion plates,whichspreadthe inlet air flow across thewholesurfaceofthe end. (see
illustration).
Flue pipes
Outlet air pipe
-Pipingofthe heater

ANTTI-TEOLLISUUSOY 9
- A4.0m longfluepiping andraincap areincludedin thedelivery.Inmostcasesthisis enough
forverticalpipeinstallations.
- Oftenthefluepipemustalsobeledhorizontallythroughtheheaterroomwallandthepartsof
theverticalpipeareinstalledinverticalpositionoutsidetheheaterroom.Inthis case,
additionalflue pipe elbows andparts of straight pipe areneeded forinstallation. Note the
condensationof sulphurina claypipe.Itisadvisable toinstall thefirst partofthefluepipein
a vertical positionso that thecondensed liquid willnotflow backinto theheater. Fromthis
point on theflue pipecan bedirectedstraight upwards.
- Payspecialattentiontosufficientsupportingand stayingofthepipe. Atmaximum4.0mtall
vertical pipesare allowedto besupportedonly bythe heater. Thelonger pipesand elbows
requirea separatesupportingstructure.Averticalpipemustalsobesupportedsideways
eitherwith staywiresorsupportingbars.
- Ifthe heater is installedoutdoors,theburner must becoveredcompletelyagainst rain and
snow.The electric motor andoilburnerarenot covered against rain.
3. Oil Burner and Pipes
Theinstallationandadjustmentofthe oilburnerandtheinstallationoftheoilpipesmustbeleft
toan authorised oilburnermechanic.
Instructionsfortheoilburnermechanic:
- Useexclusively 2-pipesystemwith10/12mmcopperpipes.
- Alwayscheckthesizeofthenozzlesbeforeputtingtheheaterintoservice.
Pleaserefertothelowerpartofthetableonthelastpageforrecommendedoilflowforthe
heaters.Thevaluesin the tablefor the heaterairadjustmentare only indicative.Assigna
specializedmechanic for more accurateadjustment.
Nozzles:
- Danfoss 80°, spray patternS or B
- Monarch80°,spraypatternR orPLP
Ifyouwant maximumoutputfromtheheater,seetheoilpressuretable(onthelastpageofthis
manual) tofindouthowtheoilpressureaffectstheamountofburningoilwhendifferentnozzles,and
pairsofnozzles,areused
NOTE! Do not install over-sized nozzles or adjust the oil pressure setting so high
that the maximum permissible oil amount for the burner will be exceeded
Este manual sirve para los siguientes modelos
4
Tabla de contenidos
Otros manuales de Calentador de ANTTI
Manuales populares de Calentador de otras marcas

Empire Heating Systems
Empire Heating Systems WCC65 Manual de usuario

Wetekom
Wetekom 92 86 43 Manual de usuario

Desa
Desa SPC170-F Manual de usuario

Watlow
Watlow Watrod Electric Tubular Heaters Manual de usuario

Haverland
Haverland ECO-DRY GPS Series Manual de lista de piezas

Stelpro
Stelpro ASILVC2060 Series Manual de usuario