Anolis ArcPower 16x6 Manual de usuario

Version 1.1

2
Table of contents
1. Safety instructions ......................................................................................................... 3
2. Operating determinations.............................................................................................. 3
3.Description of the ArcPower 16x6 ................................................................................. 4
4.Installation........................................................................................................................ 4
4.1.Connection to the mains: ........................................................................................... 4
4.2.Mounting the ArcPower 16x6 ..................................................................................... 5
4.3.Conection cables........................................................................................................ 5
5 DMX operation ................................................................................................................ 6
5.1 Single ArcPower 16x6 installation.............................................................................. 6
5.2 Multiple ArcPower 16x6 installation ...........................................................................7
6.ArcPower 16x6 - Control menu map.............................................................................. 8
7.ArcPower 16x6 - DMX protocol, version 1.1 ................................................................. 9
8.Control board................................................................................................................. 15
8.1 Addressing the ArcPower 16x6 ............................................................................... 15
8.2 Program editing........................................................................................................ 15
8.3 Manual mode ........................................................................................................... 16
8.4 Test sequences........................................................................................................ 16
8.5 Stand-alone mode.................................................................................................... 17
8.6 Special functions ...................................................................................................... 17
9.Technical Specications: ............................................................................................. 19
10. Replacing the fuse ..................................................................................................... 20
ArcPower 16x6

3
CAUTION!
Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOU INITIAL START - UP!
1. Safety instructions
Every person involved with installation and maintenance of this product has to:
- be qualiled
- follow the instructions of this manual
CAUTION!
Be careful with your operations. With a high voltage you can suffer
a dangerous electric shock when touching the wires inside the unit!
This product has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this manual.
To prevent from danger of accident ,the device has to be xed on at, non-amma-
ble surface in compliance with the installing instruction included in this manual.
Important:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this
manual or any unauthorized modication to the product.
Always ground the unit.
The electric connection, repairs and servicing must be carried out by a qualied employee.
Do not connect this unit to a dimmer pack.
Use a source of AC power that complies with local building and electrical rules.AC power has to have both
overload and short circuit protection
2. Operating determinations
This product was designed for indoor use only.
If the unit has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on
immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has
reached room temperature.
Avoid brute force when installing or operating the unit.
When choosing the installation-spot, please make sure that the unit is not exposed to extreme heat, moisture
or dust.
Only operate the unit after having checked that the housing is rmly closed and all screws are tightly fas-
tened.
The maximum ambient temperature 40° C must never be exceeded.
Operate the unit only after having familiarized with its functions. Do not permit operation by persons not quali-
ed for operating the unit. Most damages are the result of unprofessional operation!
Please use the original packaging if the product is to be transported.
Please consider that unauthorized modications on the unit are forbidden due to safety reasons!

4
3.Description of the ArcPower 16x6
LED output zones (RGB operation)
LED output zones (RGBW operation)
DMX Input,Output LED module Input
RJ45 socket RJ45 socket
Front view of the socket: Front view of the socket:
4.Installation
4.1.Connection to the mains:
The ArcPower 16x6 is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz
AC power source from 100-240 Volts.
Carefully prepare the end of the the supply cord and t a suitable plug.A 3-prong grounding-type plug must be
installed following the manufacturer´s instructions.The earth has to be connected!
1- Control board
2- LED output zones
3- DMX Input
4- DMX Output
5- Fuse holder
6- Power cord
Pin 1: Not connected Pin 5: +5V
Pin 2: Not connected Pin 6: Data +
Pin 3: Not connected Pin 7: Data -
Pin 4: Not connected Pin 8: GND
Pin 1: Red LED + Pin 5: Red LED -
Pin 2: Green LED + Pin 6: Green LED -
Pin 3: Blue LED + Pin 7: Blue LED -
Pin 4: White LED + Pin 8: White LED -

5
Cord plug connection:
Cable Pin International
Brown Live L
Light blue Neutral N
Yellow/Green Earth
This device falls under protection class I.Therefore the ArcPower 16x6 has to be
connected to a mains socket outlet with a protective earthing connection.
4.2.Mounting the ArcPower 16x6
The ArcPower 16x6 should be be placed on a non-ammable at surface in any orientation and xed by the
four screws.There are four mounting holes of a diameter 5 mm in housing of the driver. Ensure that instalation
place is enough ventilated.
4.3.Conection cables
1.The adapter cable RJ45/XLR connects the ArcPower 16x6 to the DMX controller.If your DMX controller has
RJ45 socket for DMX output,use RJ45 patch cable for connection with the ArcPower 16x6.
RJ45 plug DMX 512 XLR plug (male)
View facing pins Front view of the plug
Pin 1: Not used Pin 1: GND
Pin 2: Not used Pin 2: Data -
Pin 3: Not used Pin 3: Data +
Pin 4: Not used Pin 4: Not used
Pin 5: +5V Pin 5: Not used
Pin 6: Data +
Pin 7: Data -
Pin 8: GND
Flat surface
Mounting hole
Screws
Screws

6
2.RJ45 patch cables category 5 that connect the ArcPower 16x6 each other are wired 1:1,that is,pins with the
same numbers are connected together.
Pin 1: Not used Pin 1: Not used
Pin 2: Not used Pin 2: Not used
Pin 3: Not used Pin 3: Not used
Pin 4: Not used Pin 4: Not used
Pin 5: +5V Pin 5: +5V
Pin 6: Data + Pin 6: Data +
Pin 7: Data - Pin 7: Data -
Pin 8: GND Pin 8: GND
5 DMX operation
1.Unplug from the mains before installation.
2.Connect the LED modules to the xture according to the operation (RGB or RGBW).
3.Connect DMX controller to the xture
4.Connect the xture to the mains
5.Set the DMX address on the control board of the xture (see chapter "Control board").
6.Run internal calibration of the xture (menu path: SPEC-->CALi--->COMP.)
Warning!
Accidental connection DMX 512 Input/Output to non-DMX 512 device (e.g.Ethernet
network Hub) can damage the ArcPower 16x6.
Maximum total cable length between Arcpower 16x6 and all connected LED modu-
les is 80 metres.
5.1 Single ArcPower 16x6 installation
1. RGB operation
Max. load per LED output zone: 6x1W LED
Number of zones: 16
2. RGBW operation
The ArcPower 16x6 allows to operate 12 RGBW outputs (zones) and it is not necessary to change its menu
setting. You can choose Mode1 for RGBW (up to DMX 48 channels) or Mode2 including the shutter (DMX=
49) and dimmer (DMX= 50) channel - see DMX protocol for RGBW operation.
Note: Only 12 zones of the ArcPower 16x6 can be used for RGBW operation - see chapter 3 "Description
of the ArcPower 16x6".

7
5.2 Multiple ArcPower 16x6 installation
Connect the DMX output of the rst ArcPower 16x6 with the DMX input of the next ArcPower 16x6. Always
connect one output with the input of the next ArcPower 16x6 until all xtures are connected.In this way,up to
32 xtures can be chained together.
At the last ArcPower 16x6 the data link has to be terminated with a terminator. A termination plug is simply a
RJ45 connector with a 120 Ω resistor between pins Data (–) and Data (+).Plug terminator in the DMX output
of the last ArcPower 16x6.
Max. load per LED output zone: 8x1W LED
Number of zones: 12

8
6.ArcPower 16x6 - Control menu map
Default settings=Bold print
A001 (001-464)
ProG
EPG.1
:
EPG.4
St.01
:
St.60
rEd 1 (0-255)
:
dimr. (0-255)
F.tim.(0-255)
S.tim. (0-255)
COPY
P.End. (1-60)
MAn.C.
rEd.1 (0-255)
GrE.1 (0-255)
bLu.1 (0-255)
:
Stro. (0-255)
dimr (0-255)
tESt
St.AL.
Auto
OFF
tESt
:
PrG.5
PLAY.
EPG.1
:
SPEC. PrG.5
VErS
tEmP
CALi
rEd.1 (0-255)
:
bL.16 (0-255)
Stor.
COMP.
bALA. (On,OFF)
C.bAL.
rEd.b. (0-255)
GrE.b.(0-255)
bLu.b. (0-255)
CHAr
EYE
LinE
dM.Pr.
Mod.1
Mod.2
i.bLi (On,Off)
dFSE (no,YES)
uPd (no,YES)

9
7.ArcPower 16x6 - DMX protocol, version 1.1
RGB operation
Mode 1 Mode 2
Value Function Type of con-
trol
Channel Channel
ZONE 1
1 1 0-255
Red LED 1
Red LED saturation control (0-100%) proportional
2 2 0-255
Green LED 1
Green LED saturation control (0-100%) proportional
3 3 0-255
Blue LED 1
Blue LED saturation control (0-100%) proportional
ZONE 2
4 4 0-255
Red LED 2
Red LED saturation control (0-100%) proportional
5 5 0-255
Green LED 2
Green LED saturation control (0-100%) proportional
6 6 0-255
Blue LED 2
Blue LED saturation control (0-100%) proportional
ZONE 3
7 7 0-255
Red LED 3
Red LED saturation control (0-100%) proportional
8 8 0-255
Green LED 3
Green LED saturation control (0-100%) proportional
9 9 0-255
Blue LED 3
Blue LED saturation control (0-100%) proportional
ZONE 4
10 10 0-255
Red LED 4
Red LED saturation control (0-100%) proportional
11 11 0-255
Green LED 4
Green LED saturation control (0-100%) proportional
12 12 0-255
Blue LED 4
Blue LED saturation control (0-100%) proportional
ZONE 5
13 13 0-255
Red LED 5
Red LED saturation control (0-100%) proportional
14 14 0-255
Green LED 5
Green LED saturation control (0-100%) proportional
15 15 0-255
Blue LED 5
Blue LED saturation control (0-100%) proportional
ZONE 6
16 16 0-255
Red LED 6
Red LED saturation control (0-100%) proportional
17 17 0-255
Green LED 6
Green LED saturation control (0-100%) proportional
18 18 0-255
Blue LED 6
Blue LED saturation control (0-100%) proportional
ZONE 7
19 19 0-255
Red LED 7
Red LED saturation control (0-100%) proportional
20 20 0-255
Green LED 7
Green LED saturation control (0-100%) proportional
21 21 0-255
Blue LED 7
Blue LED saturation control (0-100%) proportional
ZONE 8
22 22 0-255
Red LED 8
Red LED saturation control (0-100%) proportional
23 23 0-255
Green LED 8
Green LED saturation control (0-100%) proportional
24 24 0-255
Blue LED 8
Blue LED saturation control (0-100%) proportional

10
Mode 1 Mode 2 Value Function Type of con-
trol
Channel Channel
ZONE 9
25 25 0-255
Red LED 9
Red LED saturation control (0-100%) proportional
26 26 0-255
Green LED 9
Green LED saturation control (0-100%) proportional
27 27 0-255
Blue LED 9
Blue LED saturation control (0-100%) proportional
ZONE 10
28 28 0-255
Red LED 10
Red LED saturation control (0-100%) proportional
29 29 0-255
Green LED 10
Green LED saturation control (0-100%) proportional
30 30 0-255
Blue LED 10
Blue LED saturation control (0-100%) proportional
ZONE 11
31 31 0-255
Red LED 11
Red LED saturation control (0-100%) proportional
32 32 0-255
Green LED 11
Green LED saturation control (0-100%) proportional
33 33 0-255
Blue LED 11
Blue LED saturation control (0-100%) proportional
ZONE 12
34 34 0-255
Red LED 12
Red LED saturation control (0-100%) proportional
35 35 0-255
Green LED 12
Green LED saturation control (0-100%) proportional
36 36 0-255
Blue LED 12
Blue LED saturation control (0-100%) proportional
ZONE 13
37 37 0-255
Red LED 13
Red LED saturation control (0-100%) proportional
38 38 0-255
Green LED 13
Green LED saturation control (0-100%) proportional
39 39 0-255
Blue LED 13
Blue LED saturation control (0-100%) proportional
ZONE 14
40 40 0-255
Red LED 14
Red LED saturation control (0-100%) proportional
41 41 0-255
Green LED 14
Green LED saturation control (0-100%) proportional
42 42 0-255
Blue LED 14
Blue LED saturation control (0-100%) proportional
ZONE 15
43 43 0-255
Red LED 15
Red LED saturation control (0-100%) proportional
44 44 0-255
Green LED 15
Green LED saturation control (0-100%) proportional
45 45 0-255
Blue LED 15
Blue LED saturation control (0-100%) proportional
ZONE 16
46 46 0-255
Red LED 16
Red LED saturation control (0-100%) proportional
47 47 0-255
Green LED 16
Green LED saturation control (0-100%) proportional
48 48 0-255
Blue LED 16
Blue LED saturation control (0-100%) proportional