AMS AS5047D Manual de usuario

USB I&P Box
User Manual
www.ams.com Revision 1.4 / 09/09/2015 page 2/13
Table of Contents
1General Description ............................................................................................................. 3
2Hardware.............................................................................................................................. 4
2.1 Kit Content ........................................................................................................................... 4
2.2 Compatible Products............................................................................................................ 4
2.3 Pin-out.................................................................................................................................. 5
3First steps with the USB I&P Box......................................................................................... 5
4Connection from compatible Adapterboard to USB I&P Box............................................... 7
4.1 AS5047D/AS5147/AS5047P/AS5147P ............................................................................... 7
4.2 AS5050A/AS5055A.............................................................................................................. 7
4.3 AS5048A/AS5048B.............................................................................................................. 8
4.4 AS5510 ................................................................................................................................ 8
4.5 AS5600 ................................................................................................................................ 9
4.6 AS5601 ................................................................................................................................ 9
4.7 AS5247 .............................................................................................................................. 10
5Software............................................................................................................................. 11
5.1 GUI Overview..................................................................................................................... 11
5.2 Firmware Update................................................................................................................12
6Ordering Information.......................................................................................................... 12
Copyright ........................................................................................................................................... 13
Disclaimer..........................................................................................................................................13
Revision History
Revision
Date
Owner
Description
1.0
21.01.2014
AZEN
Initial revision
1.1
06.08.2014
RPH
Minor changes
1.2
06.10.2014
AZEN
Updated Compatible Products
1.3
12.12.2014
AZEN
Add Section 4
1.4
09.09.2015
AZEN
Add AS5047P/AS5147P/AS5247

USB I&P Box
User Manual
www.ams.com Revision 1.4 / 09/09/2015 page 3/13
1 General Description
This Manual explains how to use the USB I&P Box.
The USB I&P Box is a Programming-Tool for Magnetic Position Sensors with I2C or SPI Interface.
After connecting a Magnetic Position Sensor to I&P Box you can open the GUI on your computer
and start programming.
For programming a Magnetic Position Sensor the sensor should be mounted on a PCB to get
connected with all the necessary pins of the sensor.
For Position Sensors, ams provides Adapterboards where an easy access from the Sensor to the
USB I&P Box is possible (not in the Tool-Kit included)
Figure 1:
USB I&P Box

USB I&P Box
User Manual
www.ams.com Revision 1.4 / 09/09/2015 page 4/13
2 Hardware
2.1 Kit Content
Table 1:
USB I&P Box Kit content
Part
Description
Picture
USB
I&P Box
USB Interface & Programming Box
USB
cable
To connect the USB I&P box to a computer
10-way
cable
To connect the USB I&P Box to a compatible sensor
on an existing board
Quick
Start
Guide
First steps introduction
USB
flash
drive
Contains the USB I&P Box Software and manuals.
To get latest SW / FW and Manuals please refer to
http://ams.com/eng/Support/Demoboards/Accessories
/Evaluation-Tool/USB-I-P-Box
2.2 Compatible Products
Table 2:
Compatible Products
Product
Description
Adapterboard available
AS5047D
14-bit On-Axis Magnetic Rotary Position Sensor
yes
AS5047P
14-bit On-Axis Magnetic Rotary Position Sensor
yes
AS5048A
14-bit Angular Position Sensor with SPI Interface
yes

USB I&P Box
User Manual
www.ams.com Revision 1.4 / 09/09/2015 page 5/13
Product
Description
Adapterboard available
AS5048B
14-bit Angular Position Sensor with I2C Interface
yes
AS5050A
Low Power 10-Bit Magnetic Position Sensor
yes
AS5055A
Low Power 12-Bit Magnetic Position Sensor
yes
AS5147
14-bit On-Axis Magnetic Rotary Position Sensor
yes
AS5147P
14-bit On-Axis Magnetic Rotary Position Sensor
yes
AS5247
14-bit Dual-Die Magnetic Rotary Position Sensor
yes
AS5510
Linear Hall Sensor with I²C Output
yes
AS5600
12-bit Programmable Contactless Potentiometer
yes
AS5601
12-bit Programmable Contactless Encoder
yes
2.3 Pin-out
The pin-out of the USB I&P box is shown below in Table 3
Table 3:
USB I&P Box Pin-out and wire description
Note: The interface voltage of the USB I&P Box is 3,3V. Use the 3,3V mode when connecting to a
position sensor board.
3 First steps with the USB I&P Box
The first steps to get started with the USB I&P Box are described below in Figure 2.
Pin #
Color
Definition
SPI Mode
1
Brown
5V Supply
Not used
2
Red
3.3V Supply
Positive power supply
3
Orange
SPI-CS(0)
SPI-CS(0)
4
Yellow
I2C-SCL
Not used
5
Green
SPI-CLK
SPI-CLK
6
Blue
I2C-SDA
Not used
7
Purple
SPI-MOSI
SPI-MOSI
8
Grey
SPI-CS(1)
Optional (dual die version)
9
White
SPI-MISO
SPI-MISO
10
Black
GND
GND

USB I&P Box
User Manual
www.ams.com Revision 1.4 / 09/09/2015 page 6/13
Figure 2:
First steps with the USB I&P Box
Getting started with your programmer
Ready to start
Install the USB I&P Software on your
computer
Connect the right wires of the USB I&P
Connector cable to your magnetic position
sensor
Connect your USB I&P Box to your
computer via USB cable
Open the USB I&P Software
Choose the right Device
For using the right wires
please refer to Table 3

USB I&P Box
User Manual
www.ams.com Revision 1.4 / 09/09/2015 page 7/13
4 Connection from compatible Adapterboard to USB I&P Box
4.1 AS5047D/AS5147/AS5047P/AS5147P
Figure 3:
How to connect an AS5047D/AS5147/AS5047P/AS5147P adapterboard to the USB I&P Box
4.2 AS5050A/AS5055A
Figure 4:
How to connect an AS5050A/AS5055A adapterboard to the USB I&P Box
Este manual sirve para los siguientes modelos
11
Tabla de contenidos
Otros manuales de Unidad de control de AMS
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario