Amplitec W20-GSM Manual de usuario

User Manual of
W20-GSM indoor single
bandselectiverepeaters
Amplitec Corporation

User Manual of W20-GSM Indoor single band selective repeaters
Confidential Page 1
CATALOGUE
CHAPTER 1. SAFETY WARNNING................................................................................2
CHAPTER 2. SUMMARY ................................................................................................3
CHAPTER 3. SPECS AND FEATURES..........................................................................4
3.1 F
EATURES
...............................................................................................................................4
3.2 S
YSTEM DIAGRAM
....................................................................................................................4
3.3 E
LECTRICAL
S
PECIFICATION
.....................................................................................................4
3.4 M
ECHANICAL
S
PECIFICATION
....................................................................................................4
3.5 A
PPEARANCE
D
IAGRAM
...........................................................................................................6
3.6 P
ORTS
.....................................................................................................................................6
CHAPTER 4. INSTALLATION.........................................................................................7
4.1
I
NSTALLATION REQUIREMENTS
.......................................................................................................7
4.2
I
NSTALLATION
...............................................................................................................................7
4.3
C
ONNECTION
................................................................................................................................9
4.4
S
YSTEM INSPECTION
...................................................................................................................10
CHAPTER 5. REPEATER SETTING.............................................................................10
5.1
P
OWER SUPPLY CONNECTION
......................................................................................................10
5.2
P
ERFORMANCE
S
ETTING
.............................................................................................................11
CHAPTER 6. ENGINEERING MAINTENANCE ............................................................13
6.1
O
PERATION AND MAINTENANCE
...................................................................................................13
6.2
E
MERGENCY DEALING
.................................................................................................................13
6.3
M
AINTAINING DIRECTIONS
............................................................................................................14

User Manual of W20-GSM Indoor single band selective repeaters
Confidential Page 2
Chapter 1. Safety Warnning
Users must follow the below principles:
1. Repeater should follow system requirement of communication equipment, assure
good groundings and lightning protection.
2. The power supply voltage of repeater should meet the standards of security
requirement; any repeater-operator can operate only after cutting power in advance.
Only the professional can operate electrified.
3. Do not dismantle machine, maintain or displace accessories by yourself, because in
this way, the equipment may be damaged or even get an electric shock.
4. Do not open the repeater, touch the module of repeater, even not to open the cover
of module to touch the electronic component, the components will be damaged due
to electrostatic
5. Please keep away from heating-equipment, because the repeater will dissipate heat
when working. And do not cover repeater with anything that influences
heat-dissipation.

User Manual of W20-GSM Indoor single band selective repeaters
Confidential Page 3
Chapter 2. Summary
In mobile communication, it is inevitable that macro-cell coverage cannot cover weak
or dead zones; to use repeater is a good choice in these areas. Single band selective
repeaters mainly applied in covering small blind and weak zones.
Indoor single band selective repeater W20-GSM is a good choice for VIP rooms,
offices, houses, restaurants, apartments, packing, etc.
Picture 2.1 Application
Indoor single band selective repeater W20-GSM enhances consumer satisfaction
greatly with its integrated design, compact size, easy engineering and rapid installation
and debugging,
Indoor single band selective repeater W20-GSM is made with the characteristics
of industrial aesthetic design, and thus can be installed in high-class places as a
decoration.
SAW filter technology enables it to amplify only the targeted operator’s signals and
reject all the others effectively, it is, therefore, an optimal solution for coverage
extension.

User Manual of W20-GSM Indoor single band selective repeaters
Confidential Page 4
Chapter 3. Specs and features
3.1 Features
zAdjustable range of 31dB at 1dB per step.
zAdvanced digital controlled frequency selection to ensure high out of band
rejection.
zHighly stable power design, to work normally even in very tough power
environments.
zALC technology to maintain stabile signal in coverage areas
3.2 System diagram
3.3 Specification
W20-GSM
Electrical Specification Uplink Downlink
Frequency Range 890.1 ~ 901.1 MHz 935.1 ~ 946.1 MHz

User Manual of W20-GSM Indoor single band selective repeaters
Confidential Page 5
Max.Gain ≧65dB ≧70dB
Band width 11MHz
Gain Adjust Range 31dB in step of 1dB
Automatic Level Control ≧20dB
Ripple in Band(P-P)≤3dB
Output Power ≧15dBm ≧20dBm
Max. Input Power Without Damage ≦0dBm
± 400 KHz ≦+50dB
± 600 KHz ≦+40dB
± 1 MHz ≦+35dB
Out of Band Gain
± 5 MHz ≦+25dB
9KHz~1GHz ≦-36dBm
Intermodulation
Products 1GHz~12.75GHz ≤-30dBm
9KHz~1GHz ≦-36dBm
Spurious Emission 1GHz~12.75GHz ≦-30dBm
Noise Figure ≦6dB
VSWR ≦2dB
Time Delay ≦5μs
MTBF >50000hours
Power Supply AC160~264V, 50/ 60Hz
Impedance 50 ohm
Mechanical Specification
I/O Port N-Female
Dimensions (D x W xH ) 268*225*58mm
Weight ≦3.5Kg
Installation Type Wall Installation
EnvironmentConditions IP40
Environmental Specifications
Humidity < 90%
Operating Temperature -10℃~55℃
LED Indication
Power LED DC ON/OFF
ALC 1~5dB,orange
Alarm LED ALC 20~25dB,red

User Manual of W20-GSM Indoor single band selective repeaters
Confidential Page 6
3.4 Appearance Diagram
3.5 Ports

User Manual of W20-GSM Indoor single band selective repeaters
Confidential Page 7
Chapter 4. Installation
4.1 Installation requirements
Indoor single band selective repeaters W20-GSM are mainly applied as indoor
coverage system, the changes of air moisture and temperature may influence its
reliability. So such factors as the temperature, air moisture, dustproof, current source
and space requirement, etc shall be fully considered during installation.
Position selection
¾Install in the place that is not easy to be reached by irrelevant people.
¾Install at the place that is convenient for power supply and cabling.
¾Avoid heat source and moist environment
¾Install at drought space, hang on wall vertically in order to assure good heat
distribution.
Power supply requirement
AC power supply of
160~264V, 50/ 60Hz
Installation tools and accessories
Serie
s item specification Quantity Remarks
1 Expanding plug M7 4 Accessories
2 Tapping screw M6*40 4 Accessories
3 Spinner
4 Waterproof tape
5 Ruler
1 measurement and installation of hole
6 Percussion drill 1 drilling on wall
4.2 Installation

User Manual of W20-GSM Indoor single band selective repeaters
Confidential Page 8
Picture 4.1 Installation diagram
Picture 4.2 Hole positions

User Manual of W20-GSM Indoor single band selective repeaters
Confidential Page 9
Installation Steps:
A) Use percussion drill to make four Φ6 holes on the wall according to
above hole diagram.
B) Fill the holes with expanding plug
C) Put the tapping screw through the holes and fit tightly with the
expanding plug, and fasten the repeater onto the wall.
D) Make sure that the installation is firm and correct
4.3 Connection
Connection of RF cable
Input Port : donor antenna cable is connected with BS Port;
Output Port : service antenna cable is connected with Output Port;
Grounding
Please connect one end of a copper wire with the intersection size of
16mm2 with the grounding screw, and the other end with the grounding system
of the building. It is requested that the grounding impedance shall be less than
10Ohm.
Power supply connection
Installation of air switch is recommended for the convenience of power
supply switch off.
Please use three-pin plug to assure good grounding
Please use the grounding screw, nut, washer to connect the grounding wire and
repeater shell
Lightening Arrestor can be installed if necessary
Tabla de contenidos
Otros manuales de Reloj de repetición de Amplitec

Amplitec
Amplitec C10 Series Manual de usuario

Amplitec
Amplitec C15-WCDMA Manual de usuario

Amplitec
Amplitec C10 Series Manual de usuario

Amplitec
Amplitec C23S Series Manual de usuario

Amplitec
Amplitec C20M-5B Series Manual de usuario

Amplitec
Amplitec C23S Series Manual de usuario

Amplitec
Amplitec C20W Series Manual de usuario

Amplitec
Amplitec C23S-EGSM Manual de usuario