AMOT G Series Manual de usuario

Doc No: OMMGGP00185
Revision: 5
Date: MAY 2019
Model G Valve
(Pneumatically Actuated)
Installation, Operation and
Maintenance Manual


3
Contents
OMMGGP00185 Rev 5 – MAY 2019
Introduction ...................................................................................................... 5
1.1 Scope of Manual ............................................................ 5
1.2 Safety........................................................................... 5
1.3 Product Support ............................................................. 6
1.4 Typographical Conventions .............................................. 6
1.5 European Union Directives............................................... 7
System Overview ............................................................................................. 9
2.1 Description .................................................................... 9
2.2 Identification of Model Number ...................................... 11
2.3 Modes of Operation ...................................................... 12
2.4 System Components ..................................................... 12
Valve Body ....................................................................................................... 15
3.1 Description .................................................................. 15
3.2 Installation .................................................................. 15
3.3 Operation .................................................................... 15
3.4 Maintenance ................................................................ 16
Pneumatic Actuator 82046L ...................................................................... 21
4.1 Description .................................................................. 21
4.2 Installation .................................................................. 22
4.3 Operation .................................................................... 30
4.4 Maintenance ................................................................ 31
Pneumatic Positioner 47224X .................................................................. 47
5.1 Description .................................................................. 47
5.2 Installation .................................................................. 49
5.3 Operation .................................................................... 50
5.4 Maintenance ................................................................ 50
Elect/Pneumatic Converter 8064A/C .................................................... 55
6.1 Overview .................................................................... 55
PID Controller 8071D .................................................................................. 57
7.1 Overview .................................................................... 57
Pneumatic Indicator Controller SG80 .................................................... 59
8.1 Overview .................................................................... 59
Temperature Sensor 8060 ......................................................................... 61
9.1 Description .................................................................. 61
9.2 Installation .................................................................. 61
9.3 Maintenance ................................................................ 62
System Integration ....................................................................................... 63
10.1 Installation Guidance Notes ........................................... 63
10.2 System Options ........................................................... 67

4
Contents
Rev 5 – MAY 2019 OMMGGP00185
Troubleshooting............................................................................................. 69
11.1 Troubleshooting ........................................................... 69
Servicing Schedule ....................................................................................... 70
12.1 Overview ..................................................................... 70
12.2 Service Intervals .......................................................... 70
12.3 Minor Service (every 2 years) ........................................ 70
12.4 Major Service (every 4 years) ........................................ 71
12.5 AMOT Field Service ....................................................... 73
Technical Data ................................................................................................ 74
13.1 Selection of G-Valve options .......................................... 74
13.2 Technical Specifications ................................................. 83

5
Introduction
OMMGGP00185 Rev 5 – MAY 2019
Section 1
Introduction
Contents
Para Page
1.1 Scope of Manual .......................................................................... 5
1.2 Safety ........................................................................................ 5
1.3 Product Support .......................................................................... 6
1.4 Typographical Conventions ........................................................... 6
1.5 European Union Directives ............................................................ 7
1.5.1 EU Machinery Directive ...................................................... 7
1.5.2 EU Pressure Equipment Directive ........................................ 7
1.1 Scope of Manual
This manual contains the information to install, operate and maintain the
pneumatically operated G Valve system. It is divided into sections as follows:
Section 1 Introduction ........................................... Page 5
Section 2 System overview ..................................... Page 7
Section 3 Valve body ............................................. Page 15
Section 4 Pneumatic actuator ................................. Page 21
Section 5 Pneumatic positioner ............................... Page 47
Section 6 Electro-pneumatic converter ..................... Page 55
Section 7 PID controller ......................................... Page 57
Section 8 Pneumatic indicator controller ................... Page 59
Section 9 Temperature sensor ................................ Page 61
Section 10 System integration .................................. Page 63
Section 11 Troubleshooting ...................................... Page 69
Section 12 Servicing Schedule .................................. Page 70
Section 13 Technical data ........................................ Page 74
1.2 Safety
Some operations in this manual can be hazardous and cause injury to people
or damage to equipment if the procedure is not done exactly as written. Where
there is a hazard, the following text appears immediately before the steps in a
procedure that can cause a hazard:

6
Introduction
Rev 5 – MAY 2019 OMMGGP00185
WARNING
A Warning identifies a step in a procedure that can cause injury to
people. The warning identifies the hazard and lists the precautions
that must be taken before the next step of the procedure is done.
CAUTION
A Caution identifies a step in a procedure that can cause damage to
equipment. The caution identifies the hazard and lists the precautions
that must be taken before the next step of the procedure is done.
Note
A Note contains more information that may be useful to the Operator and
can appear before or after a procedure step.
When installing, commissioning, operating or carrying out maintenance on the
unit, personnel must use safe working practices and observe all relevant local
health and safety requirements and regulations.
1.3 Product Support
All necessary settings are described in this manual. If any difficulties arise
during start-up, you are asked not to carry out any unauthorised actions on
the unit. You could endanger your rights under the equipment warranty.
For rapid spares and service support, call the telephone number listed on the
back cover of this manual.
1.4 Typographical Conventions
Footnotes
Where space in the text or figures to place a note is restricted, a footnote is
used. They consist of two parts:
A mark indicating which part of the text or figure is affected by the note.
This takes the form of a superscript number e.g. Abc 1.
A note in smaller font at the bottom of the affected page beginning with
the corresponding number in the text (see bottom of page):
1 This footnote applies to the part of the text or figure, marked with a superscript number 1.

7
Introduction
OMMGGP00185 Rev 5 – MAY 2019
1.5 European Union Directives
1.5.1 EU Machinery Directive
The AMOT Model G Valve, as a component, is not considered to be a machine.
To fully comply with the Directive however, the machine into which the valve is
installed must comply with the requirements of the machinery directive before
the valve is put into operation.
1.5.2 EU Pressure Equipment Directive
In its design application of a temperature control valve, the AMOT Model G
Valve is defined as a Pressure Accessory under the terms of the EU Pressure
Equipment Directive (PED).
Valves used with fluids defined as Group 2 in the Directive (such as water and
lubricating oil) fall into the Sound Engineering Practice (SEP) category.
Some valves are also rated for use with Group 1 liquids under the SEP
category.
Table 1 contains details of the groups each valve type falls into and the
associated maximum working pressure of the valve.
Table 1 Pressure Equipment Directive Table
Valve
Material
Valve
Type
Flange
Standard
Flange
Class
(PED) suitable for
liquids to group(s):
Maximum
Working
Pressure (BAR)
Ductile Iron
02GGH
03GGS
03GGH
04GGS
04GGH
05GGS
06GGS
06GGH
08GGS
EN1092 PN6
1 & 2
(SEP)
6
JIS 5K 7
EN1092 PN10
10
PN16
ASME 125
150
JIS 10K
08GGH
10GGS
EN1092 PN6
2
(SEP)
6
JIS 5K 7
EN1092 PN10
10
PN16
ASME 125
150
JIS 10K
Users who are uncertain as to the applicability of the Directive should contact
AMOT before installation, particularly if using more hazardous (Group 1) fluids.

8
Introduction
Rev 5 – MAY 2019 OMMGGP00185

9
System Overview
OMMGGP00185 Rev 5 – MAY 2019
Section 2
System Overview
Contents
Para Page
2.1 Description ................................................................................. 9
2.1.1 Features .......................................................................... 9
2.1.2 Typical Applications ......................................................... 10
2.2 Identification of Model Number .................................................... 11
2.3 Modes of Operation .................................................................... 12
2.4 System Components .................................................................. 12
2.1 Description
The G Valve and its supporting equipment are designed for the control of fluid
temperature by ‘diverting’ or ‘mixing’ control techniques.
The valves can be used for fresh water, most lubricating oils and other liquids.
The compact construction of the G Valve enables unobstructed, full-bore flow,
thus minimising pressure losses.
2.1.1 Features
The G Valve system has the following main features:
Any direction of rotation.
Any rotor-port configuration (most models).
Compact construction.
Low pressure drop.
High accuracy ( 1 C or better).
Mount in any position.
Optional manual override.
Temperature up to 100 C (212 F).
Local valve position indication.

10
System Overview
Rev 5 – MAY 2019 OMMGGP00185
2.1.2 Typical Applications
Lubricating Oil Temperature Control
Lubrication oil temperature control is
normally configured in a mixing application
controlling the return temperature to the
heat load.
The temperature is normally measured as
close as possible to the sump return.
Jacket Water Cooling
Jacket water cooling in diverting
applications regulates the outlet coolant
water temperature from a diesel or gas
engine. The valve either sends water to a
cooler or bypass loop, accurately
maintaining the temperature.
The temperature is normally measured at
the outlet from the heat source.
Charge Air Temperature Control
The intercooler is used to cool high
temperature turbo charger air. In this
application, the G Valve regulates the flow
of cooling water through an intercooler,
which can increase efficiency, enhance
performance and help meet stringent
environmental requirements
Central Cooling
For large flow central cooling, mixing or
diverting applications where accurate
temperature control is required. The
capabilities of the G Valve provide the ideal
solution.
Otros manuales para G Series
2
Este manual sirve para los siguientes modelos
12
Tabla de contenidos
Otros manuales de Unidad de control de AMOT
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario