ALLOMATIC TORO 24 Manual de usuario

SWING GATE OPENER
INSTALLATION MANUAL
®
TORO 24
UL325
Compliant
Compliant
Compliant
UL991
CSA C22.2
Canada
L
I
S
T
E
D
®
US
Compliant
Copyright © 2017 all-o-matic inc. www.allomatic.net WWW.ALLOMATIC.NET


1
TABLE OF CONTENTS
SAFETY AND INTRODUCTION
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
UL 325 Cass Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operator Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Parts Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
INSTALLATION
Pull to Open Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Push to Open Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Operator Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Entrapment Protection Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Loop Layout................................................11
Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Gate Travel Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
BOARD FEATURES
Setting and Diagnostic Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-15
Gate Opening Direction Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Programmable Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Electronic Reversing Device (ERD) Adjustment . . . . . . . . . . . . . . . . . . . . 18
Timer Adjustment and Radio Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Dip Switch Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
LED Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
WIRING ACCESSORIES TO CONTROL BOARD
Accessory Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Monitored Entrapment Protection Device Connection . . . . . . . . . . . . . 23-24
Loop Rack Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Three-Button Station Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Magnetic/Solenoid Lock Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Radio Receiver Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
SOLAR INSTALLATION
Solar Panel Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
External Solar System Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
EMERGENCY RELEASE INSTRUCTIONS............................31
WARRANTY AND CUSTOMER RECORD.............................32
PARTS BREAKDOWN..................................Check Website

2
IMPORTANT SAFETY INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF :INJURY
READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. DO NOT START INSTALLATION UNTIL
YOU HAVE READ AND UNDERSTAND THESE DIRECTIONS. IF THERE IS SOMETHING YOU DO NOT
UNDERSTAND, PLEASE CALL US.
NEVER let children operate or play with gate controls.
Locate the control station and make sure it is (a) within sight of the gate and (b) at a minimum height of 5
feet so small children cannot reach it.
Install the enclosed entrapment warning signs next to the control station and in a prominent location.
For operators equipped with a manual release, instruct the end user on the correct operation of the manual
release. Use the manual release only when the gate is not moving. It is advised that the power be turned
off.
Always keep people and objects away from the gate. No one should cross the path of a moving gate.
The gate operator must be tested monthly. The gate must reverse on contact with a rigid object, or stop
when an object activates the non-contact sensor(s). Always re-test the operator after adjusting the limits
and/or force. Failure to adjust and re-test the gate operator properly may cause sever injury or death.
Keep gate(s) properly maintained. Have a qualified service technician make repairs to gate hardware and
make proper adjustments to gate operator.
This gate entrance/exit is for vehicles only. Pedestrians must use a separate entrance.
There is nothing on a gate operator that is easily repaired or adjusted without a great deal of experience.
Call a qualified gate service technician who knows your gate operator.
SAVE THESE INSTRUCTIONS

3
IMPORTANT SAFETY INSTRUCTIONS (CONTINUED)
BEFORE GATE OPERATOR INSTALLATION
ŸConfirm that the gate operator being installed is
appropriate for the application.
ŸConfirm that the gate is designed and built
according to the current published industry
standards.
ŸConfirm that all appropriate safety features and
safety accessory devices are being installed,
including all entrapment protection devices.
ŸMake sure that the gate opens and closes freely
(by hand) before installing the operator.
ŸRepair or replace worn or damaged gate
hardware before installing the gate operator.
ŸEliminate all gaps in the sliding gate below a 6
foot height that permits a 2 1/4” sphere to pass
through any location. This includes the area of
the adjacent fence covered when the gate is in
the open position
ŸEliminate all gaps in a swing gate below a 4 foot
height that permits a 4” sphere to pass through
any location. This includes the hinge area of the
gate.
GATE OPERATOR INSTALLATION
ŸOperator must be disconnected from the power
source before attempting any installation of
accessories.
ŸInstall gate operator according to the installation
instructions in this manual.
ŸAdjust the operator clutch or load sensing device
to the minimum force setting that will allow for
reliable gate operation.
ŸInstall the operator inside the fence line. Do not
install the operator on the public side of the fence
line.
ŸInstall a proper electrical ground to the gate
operator.
ŸControls intended for user activation must be
located at least 6 feet away from any moving part
of the gate, and where the user is prevented
from reaching over, under, around, or through
the gate to operate the controls.
ŸOutdoor or easily accessible controls shall have
a security feature to prevent unauthorized use.
ŸThe stop and/or reset button must be located in
the line of sight of the gate. Activation of the
operator reset control shall not cause the
operator to move.
ŸInstall a minimum of 2 warning signs, one on
each side of the gate where they are easily
visible.
ŸTake pictures of the installation.
ŸTest all safety features for proper function before
placing the automatic vehicular gate in
operation.
MAINTENANCE
ŸTrain owners/users on the basic functions and
safety features of the gate system, including
how to turn off the power and operate the
manual disconnect feature.
ŸLeave safety instructions, product literature,
installation manual, and maintenance manual
with the owner or end user.
ŸExplain to the owner or end user the importance
of routine service and operator testing on a
monthly basis.
INSTALL THE GATE OPERATOR ONLY WHEN YOU
HAVE READ THE FOLLOWING

4
UL 325 CLASS TYPES AND OBSTRUCTIONS SENSING SYSTEMS
UL 325 CLASS TYPES
CLASS ONE: RESIDENTIAL
ŸA vehicular gate operator intended for use in
garages or parking areas associated with a
residence of one to four single families.
CLASS TWO: COMMERCIAL OR GENERAL
PUBLIC ACCESS
ŸA vehicular gate operator intended for use at a
commercial location or building, such as a
multi-family housing unit (five or more single
family units), hotel, garages, retail stores, or
other buildings accessible by or servicing the
general public.
CLASS THREE: INDUSTRIAL OR LIMITED
ACCESS
ŸA vehicular gate operator intended for use at
an industrial location or building, such as a
factory, loading dock area, or other locations
not accessible by or intended to service the
general public.
CLASS FOUR: RESTRICTED ACCESS
ŸA vehicular gate operator intended for use at a
guarded industrial location or building, such as
airport security areas or other restricted
access locations not servicing the general
public and where unauthorized access is
prevented via supervision by security
personnel.
THE SIX TYPES OF OBSTRUCTION
SENSING SYSTEMS
TYPE A:
ŸInherent entrapment protection system. This
system must sense and initiate the reverse of
the gate within 2 seconds of contact with a
solid object.
TYPE B1:
ŸNon-contact sensor (photoelectric sensor or
equivalent). This system shall, upon sensing
an obstruction in the direction of the gate
travel, reverse the gate within a maximum of 2
seconds.
TYPE B2:
ŸContact sensor (edge device or equivalent).
This system shall, upon sensing an obstruction
in the direction of the gate travel, initiate the
reversal of the gate within a maximum of 2
seconds.
TYPE C:
ŸInherent force limiting, inherent adjustable
clutch, or pressure relief valve.
TYPE D:
ŸActuating device requiring continuous pressure
to maintain opening or closing motion of the
gate.
Each class must have (2) monitored entrapment protection devices in each entrapment zone to sense and react
to obstructions within 2 seconds.
All-O-Matic’s gate operators conform to the most rigid Class One.

5
OPERATOR SPECIFICATIONS
Max Gate Weight
8’ wide gate - 1,600 lbs.
12’ wide gate - 1,200 lbs.
Max Gate Length
16’ wide gate - 800 lbs.
18’ wide gate - 600 lbs.
Warranty
4 year residential
3 year commercial
Motor
24 VDC Motor
Gate Speed
Adjustable 15-20 seconds
per 90 degree opening
Power
115 VAC single phase - 4 amps
230 VAC single phase - 2 amps
or 12/24 VDC solar panel up to 80 watts
Duty Cycle
Continuous
Temperature Range
-40º to 160º
Gear Box Ratio
N/A
Dimensions
Fully retracted arm: 38-39”
Fully extended arm: 59”
Shipping Weight
Arm: 24 lbs.
Control box: 55 lbs.
Emergency Release
Keyed manual release
Belt Size
N/A
Main Sprocket
N/A
Chain Size
N/A
Gear Box Sprocket
N/A
Limit Shaft Sprocket
N/A
Breaker Requirement
20 amp dedicated
Gearbox Pulley
N/A
Motor Pulley
N/A
UL Classes
I & II
TORO 24

6
PARTS IDENTIFICATION
O
U
R
3
6
B
S
3
O
U
R
3
6
B
S
3
O
U
R
3
6
B
S
3
ALL-O-MATIC INC.
<ENG. ESP.>
CMX-309FB C
8.0000 M
535202
CMX-309FB C
8.0000 M
535202
CMX-309FB C
8.0000 M
535202
1 2 3 4 5 6 7 8
-----------------------OPEN------------------------
5
5
MOTOR 1
MOTOR 2
SINGLE/DUAL
IN/OUT
24V AC
LINE IN EXTERNAL
S/N:
DATE:
O
U
R
3
6
B
S
3
O
U
R
3
6
B
S
3
O
U
R
3
6
B
S
3
OPEN
ERD
CLOSE
ERD
TIMER
GATE OPERATOR
BACK MOUNTING
PLATE
BACK MOUNTING
BRACKET
FRONT GATE
BRACKET
(2) EMERGENCY
RELEASE KEY
(2) PIVOT
PINS
PIVOT PIN
SECURE
SETSCREW
Exit Loop
Phantom Loop
Safety Loop
See side for
Jumper setting
Loop Connections
Exit
Loop
Loop
Loop
Safety
Phantom
24VAC/
12VDC
Ground
Exit
Phantom
Safety
LPR-1
LOOP RACK
TORO CONTROL BOARD
(2) 7AH BATTERY
TRANSFORMER
CONTROL BOX
ŸThe back mounting bracket must be cut to fit the arm geometry.
Ÿ Use the back mounting plate when a steel post is not available to weld the back mounting bracket on to.

7
PULL TO OPEN INSTALLATION
OUTSIDE PROPERTY
INSIDE PROPERTY
C
GEOMETRY OPTIONS
OPTION A B C SPEED
1 7” 5” 58” 15 SEC 90º OPENING
2 8” 6” 58” 17.5 SEC 90º OPENING
3 7.5” 7.5” 58” 19 SEC 90º OPENING
CLOSED POSITION
OPEN POSITION
For proper operation, use the installation measurements in the chart below.
If necessary, modify the gate construction for best automation performance.
Before proceeding with the gate operator installation, be sure of the following:
- The gate moves open and close freely when on manual.
- The gate hinges are properly positioned and lubricated.
- There are no obstructions in the path of the gate.
- There is no friction between the gate or ground when the gate is in motion.
B

8
PUSH TO OPEN INSTALLATION
For proper operation, use the installation measurements in the drawing below. A custom bracket is required for
this type of installation.
If necessary, modify the gate construction for best automation performance.
Before proceeding with the gate operator installation, be sure of the following:
- The gate moves open and close freely when on manual.
- The gate hinges are properly positioned and lubricated.
- There are no obstructions in the path of the gate.
- There is no friction between the gate or ground when the gate is in motion.
OUTSIDE PROPERTY
INSIDE PROPERTY
8”
58”
6”
CLOSED POSITION
OPEN POSITION
CUSTOM BRACKET
REQUIRED
(NOT PROVIDED)
Otros manuales para TORO 24
2
Tabla de contenidos
Otros manuales de Abridor de puerta de ALLOMATIC

ALLOMATIC
ALLOMATIC TORO 24 Manual de usuario

ALLOMATIC
ALLOMATIC SW-350DC Manual de usuario

ALLOMATIC
ALLOMATIC SL-100AC Manual de usuario

ALLOMATIC
ALLOMATIC TORO 24 PRIME Manual de usuario

ALLOMATIC
ALLOMATIC SL-90DC Manual de usuario

ALLOMATIC
ALLOMATIC SL-45 DC Manual de usuario

ALLOMATIC
ALLOMATIC SL-175DC Manual de usuario

ALLOMATIC
ALLOMATIC TORO 24 Manual de usuario

ALLOMATIC
ALLOMATIC SL-175 Manual de usuario

ALLOMATIC
ALLOMATIC SW-300DC Manual de usuario