ALLOMATIC SL-90DC Manual de usuario

®
UL325
compliant
compliant
UL991
L
I
S
T
E
D
®
US
SL-90DC Installation Manual
Copyright © 2008 all-o-matic inc. www.allomatic.net
WWW.ALLOMATIC.NET
Pending

TABLE OF CONTENTS
.........................................................
Different UL 325 class types........................................................
Concrete pad installation..................................................................
Different installation types (front & rear mounts)..............................
Gate travel adjustment.....................................................................
Directional settings...........................................................................
Electrical power connection..............................................................
Typical loop layout.....................................................................
Accessory connections...................................................................
Multiple safety device connection...................................................
Plugin loop detector installation......................................................
Three button station system installation..........................................
Leading edge installation................................................................
Master/Slave connection.................................................................
Magnetic/Solenoid lock installation.................................................
Radio receiver hookup....................................................................
Open and close electronic reversing sensor(ERDs) adjustment....
Timer adjustment............................................................................
Dip switch functions........................................................................
Solar panel installation...................................................................
Led diagnostics..............................................................................
Emergency release.........................................................................
Important safety instructions ....2
3&4
5
6
7
8
9
10&11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1

IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of
WARNING
injury:
READ THE FOLLOWING DIRECTIONS. DO NOT EVEN THINK OF STARTING UNTIL
YOU HAVE READ AND UNDERSTAND THESE DIRECTIONS. IF THERE IS
SOMETHING YOU DO NOT UNDERSTAND CALL US.
let children operate or play with gate controls. Keep the remote control away from
children.
Always keep people and objects away from the gate. No one should cross the path of
the moving gate.
This operator must be tested monthly. The gate must reverse on contact with a ridged
object or stop when an object activates the non-contact sensors. After adjusting the
force or the limit travel, retest the gate operator. Failure to adjust and retest the gate
operator properly can increase the risk of injury.
Use the emergency release only when the gate is not moving.
Keep gates properly maintained. Have a qualified service person make repairs to gate
hardware. It takes many years of experience to make proper adjustments to gate
hardware or operators.
This entrance is for vehicles only. Pedestrian must use separate entrance.
There is nothing on a gate operator that is easily repaired without a great deal of
experience. Save yourself some time and call a qualified Gate Service Contractor who
knows your type of gate operator.
SAVE THESE INSTRUCTIONS
Never
2

*Confirm that the gate operator being installed is appropriate for the application.
*Confirm that the gate is designed and built according to current published industry standards.
*Confirm that all appropriate safety features and safety accessory devices are being incorporated, including
both primary and secondary entrapment protection devices.
*Make sure that the gate works freely before installing the operator.
*Repair or service worn or damaged gate hardware before installation of the operator.
*Eliminate all gaps in a sliding gate below a 4 foot height that permits a 2 ¼ inch sphere to pass through
any location, including the area of the adjacent fence covered when the gate is in the open position.
*Eliminate all gaps in a swinging gate below a 4 foot height that permit a 4 inch sphere to pass through any
location, including the hinge area of the gate.
*Operator must be disconnected from the power source before attempting any installation of accessories.
*Install this gate operator according to our installation instructions.
*Adjust the operator clutch or load sensing device to the minimum force setting that will still allow for reliable
gate operation.
*Install the operator inside the fence line(do not install the operator on the public side of fence line).
*Install a proper electrical ground to a gate operator.
*Controls intended for user activation must be located at least six feet (6’) away from any moving part of the
gate and where the user is prevented from reaching over, under, around or through the gate to operate the
controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use.
The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control
shall not cause the operator to start.
*Install a minimum of two(2) WARNING SIGNS, one on each side of the gate where easily visible and take
pictures of the installation.
*Test all safety features for proper function before placing the automatic vehicular gate into service.
*Train owner/users about basic functions and safety features of the gate system, including how to turn off
the power and how to operate the manual disconnect feature.
*Leave safety instructions, product literature, installation manual and maintenance manual with end user.
*Explain to the owner/user the importance of routine service and retesting on a monthly basis.
INSTALL THE GATE OPERATOR ONLY WHEN
YOU HAVE READ THE FOLLOWING:
3

Class one: Residential
A vehicle gate operator intended for use at a home of one to four single family dwellings,
garages or parking area.
Class Two: Commercial or General Public Access
A vehicular gate operator intended for use at a commercial location or building such as a
multi-family housing unit (five or more single family units), hotel, garages, retail stores,
other buildings servicing the general public.
Class three: Industrial or limited Access
A vehicular gate operator intended for use at an industrial location or building such as a
factory, loading dock area, or other locations not intended to service the general public.
Class Four: Restricted Access
A vehicular gate operator intended for use at a guarded industrial location or building
such as airport security areas or other restricted access locations not servicing the
general public where unauthorized access is prevented via supervision by security
personnel.
Other components required to satisfy UL 325
Each class must have a primary and secondary means to sense and react to
obstructions within two seconds.
The six types of obstruction sensing systems are:
Type A:
Inherent obstruction sensing system. This system must sense and initiate the reverse of
the gate within two seconds of contact with a solid object.
Type B 1:
Provision for connection of a non-contact device can be used, such as a secondary
protection.
Type B2:
Provision for connection of a contact sensor. Examples include an edge device or
equivalent. This can be used for secondary protection.
Type C:
Inherent adjustable clutch or pressure relief valve.
Type D:
Provision for connection of or provided with and actuation device requiring continuous
pressure.
DIFFERENT UL 325 CLASS TYPES
4

5
4”
16”
CONCRETE PAD PLACEMENT
FOR SL-90DC
24”
24”
15”
18”
RED HEAD BOLTS
FOUR PLACES ½”X 3 ½”
Area for conduit(s)
Operator concrete pad
Operator frame
Operator plastic cover
GATE TRACK GATE
GATE TRACK
FOOTING
GATE TRACK
FOOTING
Minimum 5”
10”
8”
24”
4”
When possible
Install 4” above
Ground
Footing for
Gate operator
½”
10
13
½”
8 ”
14
/
Drive chain level for front
mount
Drive chain level for rear
mount
Low voltage single
conduit for Master/Slave
High voltage
conduit
Total cover higth

6
Rear mount installation
and chain layout
A front mount installation
and chain layout
DRIVEWAY
DRIVEWAY
DIFFERENT INSTALL CONFIGURATIONS
Gate in open position
Gate in open position
Gate closed
Gate closed
Gate operator
Gate operator
Operator footing
Gate operator footing
Move one idler to bottom
hole and follow
chain path as shown.
Operator footing Chain path
Gate post
Front idler
Safety guard
Gate
See blow out below
Track footing
Track footing
Track footing
Track footing
Operator footing
Operator footing
Overhead
View

7
GATE TRAVEL ADJUSTMENT
FOR SL-90DC
Limit nut lock plate
Limit nuts
Locate limit switches
Step 1: Stop the gate operator using the three button station on
the board.
Step 2: Push limit lock plate down. Turn limit nut in the desired
direction.
Step 3: Place limit plate to its locked position.
Step 4: Run gate operator.
Each notch equals
about
½” of travel.
Gear box

8
Right hand and left hand opening is from behind the operator.
OPENING DIRECTION SETTINGS
Opening Opening
RIGHT HAND LEFT HAND
1 2 3 4 5 6 7 8
-----------------------OPEN------------------------
C8RB
LMC64
82AIM
1210
1001
1001
1002
710
KE.
LED’s will show opening or
closing directions when gate
is running.
Use dipswitch to change the opening direction on the operator.
for left hand opening, for right hand opening.
OPEN L/R OFF
ON
1002
O
U
R
N
3
8
6
B
S
3
13
O
U
R
N
3
8
6
B
S
3
13
O
U
R
N
3
8
6
B
S
3
13
1 2 3 4 5 6 7 8
-----------------------OPEN------------------------
PHILIPS
PHILIPS
72CB74K G4
Ls14
72CB74K G4
Ls14
72CB74K G4
Ls14
72CB74K G4
Ls14
C8RB
LMC64
82AIM
C8RB
LMC64
82AIM
C8RB
LMC64
82AIM
C8RB
LMC64
82AIM
C8RB
LMC64
82AIM
58ADC1K G4
Ls07
58ADC1K G4
Ls07
1001
1001
1001
1001
1001
1210
1001
1001
1001
1001
1002
1002 1002 1002 1002 1002 1002 1002 1002 1002
1002
1002
1002
2001
2001
2001
4750
4750
145
1212
1212
4021
2491
2491
2262
2402
9531
4750
1131
3002
6040
1332
1001
1001
1001
20M
1001
1001
1001
1001
1001
1001
0022
1001
90R9
90R9
90R9
10R0
10R0
10R0
1000
1000
1000
1501
1501
1501
1501
1501
1501
1501
1501
1501
476E
900R3
476E
900R3
107A
911C0
F
MOC8050
629Q
MAGNECRAFT
W107DIP - 3
5W
.01
I0615
I/
O
O
710
KE.
710
KE.
710
KE.
710
KE.
710
KE.
710
KE.
710
KE.
710
KE.
710
KE.
710
KE.
710
KE.
710
KE.
SS
14
SS
14
SS
14
829B
R616
829B
R616
829B
R616
829B
R616
602
S26
S
602
S26
S
602
S26
S
CMX-309FB C
8.0000 M
535202
IR2110S
0618 IOR
IR2110S
0618 IOR
IR2110S
0618 IOR
ATMEL
ATMEGA168
20AU 0743
UC3906DW
U 74ZF2CW
MAAF
S21B
F260
104
Coilcraft
F
683
Coilcraft
V
100
HFK.
7J2
33
HFK
5GN
802
360G
B
ON
802
360G
B
ON
802
360G
B
ON
DR127-330
43CL07 E
1AM
9
1AM
9
1
2
3RS

9
230V
All gate operators be properly grounded.
A proper ground in a gate operator installation minimizes or prevents damage from an electrical charge, such as a near
lightning strike or an electrical static discharge.
.
Use a single wire for the ground. DO NOT splice two wires for the ground. If the wire breaks or is cut, replace it with a
single length. NEVER use two wires for the ground.
Check with your City code for proper earth ground rod type and proper grounding procedures.
MUST
ELECTRICAL CONNECTION
120 Volt
Electrical
Plug.
Control Box
Power connection | 115VAC | 220VAC Single Phase
LINE 1 = 115V HOT 220V LINE 1
LINE 2 = 115V N 220V LINE 2
Connect to ground. Use a proper ground rod for a
ground reference.
Use the shortest and thickest wire possible for ground.
GND
For power wire enclosure
use UL listed conduits.
OPERATORS MUST BE PROPERLY GROUNDED!
For power, a minimum of a
dedicated circuit
breaker is needed.
20-Amp
NOTE: When applying 230V to
operator make sure voltage
switch is flipped to 230V
position.
NOTE: To use the 120VAC
accessory outlet, connect white
wire from the outlet to neutral.
Only when using 120VAC as the
power source.
Power
Switch
115V
GRD LINE 1 LINE 2
Tabla de contenidos
Otros manuales de Abridor de puerta de ALLOMATIC

ALLOMATIC
ALLOMATIC SW-350DC Manual de usuario

ALLOMATIC
ALLOMATIC TORO 24 Manual de usuario

ALLOMATIC
ALLOMATIC SL-45DC Manual de usuario

ALLOMATIC
ALLOMATIC SL-45 DC Manual de usuario

ALLOMATIC
ALLOMATIC DC Series Manual de usuario

ALLOMATIC
ALLOMATIC TORO 24 Manual de usuario

ALLOMATIC
ALLOMATIC SL-100AC Manual de usuario

ALLOMATIC
ALLOMATIC SL-175DC Manual de usuario

ALLOMATIC
ALLOMATIC SW-300DC Manual de usuario

ALLOMATIC
ALLOMATIC SL-175 Manual de usuario