ALFAtron MUK44A-N Manual de usuario


ALFATRON ALF-MUK44A-N
Preface
Read this user manual carefully before using this product. Pictures shown in this
manual are for reference only, different model and specifications are subject to real
product.
This manual is for operation instruction only, not for any maintenance usage. Please
refer to the dealers for the latest details.
Trademarks
Product model, and its logo are trademarks. Any other trademarks mentioned in this
manual are acknowledged as the properties of the trademark owner. No part of this
publication may be copied or reproduced without the prior written consent.
FCC Statement
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. It has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a commercial
installation.
Operation of this equipment in a residential area is likely to cause interference, in which
case the user at their own expense will be required to take whatever measures may be
necessary to correct the interference
Any changes or modifications not expressly approved by the manufacture would void
the user’s authority to operate the equipment.

ALFATRON ALF-MUK44A-N
SAFETY PRECAUTIONS
To insure the best from the product, please read all instructions carefully before using
the device. Save this manual for further reference.
Unpack the equipment carefully and save the original box and packing material for
possible future shipment
Follow basic safety precautions to reduce the risk of fire, electrical shock and injury
to persons.
Do not dismantle the housing or modify the module. It may result in electrical shock
or burn.
Using supplies or parts not meeting the products’ specifications may cause
damage, deterioration or malfunction.
Refer all servicing to qualified service personnel.
To prevent fire or shock hazard, do not expose the unit to rain, moisture or install
this product near water.
Do not put any heavy items on the extension cable in case of extrusion.
Do not remove the housing of the device as opening or removing housing may
expose you to dangerous voltage or other hazards.
Install the device in a place with fine ventilation to avoid damage caused by
overheat.
Keep the module away from liquids.
Spillage into the housing may result in fire, electrical shock, or equipment damage.
If an object or liquid falls or spills on to the housing, unplug the module immediately.
Do not twist or pull by force ends of the optical cable. It can cause malfunction.
Do not use liquid or aerosol cleaners to clean this unit. Always unplug the power to
the device before cleaning.
Unplug the power cord when left unused for a long period of time.
Information on disposal for scrapped devices: do not burn or mix with general
household waste, please treat them as normal electrical wastes.

ALFATRON ALF-MUK44A-N
Contents
1. Introduction ................................................................................................................. 1
1.1 Brief Introduction ............................................................................................... 1
1.2 Features ............................................................................................................ 1
1.3 Package List ...................................................................................................... 1
2. Panel Description ........................................................................................................ 2
2.1 Front Panel ........................................................................................................ 2
2.2 Rear Panel ......................................................................................................... 3
3. System Connection ..................................................................................................... 4
3.1 Usage Precautions ............................................................................................ 4
3.2 Connection Diagram .......................................................................................... 4
3.3 Connection Procedure ....................................................................................... 4
3.4 System Applications .......................................................................................... 5
4. Panel Button Control ................................................................................................... 6
4.1 I/O connection switching .................................................................................... 6
4.2 EDID Configuration ............................................................................................ 6
4.3 I/O connection Inquiry ........................................................................................ 7
5. IR Control .................................................................................................................... 8
6. RS232 Control ............................................................................................................ 9
6.1 Installation/uninstallation of RS232 Control Software ........................................ 9
6.2 Basic Settings .................................................................................................... 9
6.3 RS232 Communication Commands ................................................................ 10
6.3.1 System Commands ............................................................................... 10
6.3.2 Lock/unlock Commands ........................................................................ 11
6.3.3 Switching Commands ............................................................................ 11
6.3.4 Scene Commands ................................................................................. 12
6.3.5 HDCP Compliance ................................................................................ 12
6.3.6 EDID Configuration ................................................................................ 13
6.3.7 Enable/disable Digital Audio .................................................................. 14
7. TCP/IP Control .......................................................................................................... 15
7.1 Control Modes ................................................................................................. 15
7.2 TCP/IP Communication Software Control ........................................................ 16

ALFATRON ALF-MUK44A-N
7.3 Web-based GUI Control .................................................................................. 18
7.3.1 Scene Setting ........................................................................................ 20
7.3.2 I/O connection switching ........................................................................ 21
7.3.3 EDID Configuration ................................................................................ 22
7.3.4 Audio Out ............................................................................................... 24
7.3.5 Status Setting ........................................................................................ 25
7.3.6 Network Configuration ........................................................................... 28
7.3.7 Password Modification ........................................................................... 29
7.4 TCP/IP Port Configuration ............................................................................... 30
7.5 GUI Update ...................................................................................................... 30
8. Firmware Upgrade through USB port ....................................................................... 31
9. Specification ............................................................................................................. 32
10. Panel Drawing ........................................................................................................ 33
11. Troubleshooting & Maintenance ............................................................................. 34
12. After-sales Service .................................................... Error! Bookmark not defined.

ALFATRON ALF-MUK44A-N
1
1. Introduction
1.1 Brief Introduction
MUK44A is a professional 4K 4x4 HDMI2.0 Matrix Switcher with 4 HDMI inputs, 4
HDMI outputs, and 4 SPDIF audio outputs, which is designed for switching four
HDMI2.0 and HDCP2.2 compliant signals. It also provides powerful EDID management
to ensure reliable AV distribution and routing.
You can control the unit via the front panel, IR, RS232, TCP/IP and web-based GUI.
1.2 Features
4 SPDIF ports provide de-embedded HDMI audio output;
Supports 4Kx2K@60Hz 4:4:4 & 1080p 3D signals;
Supports HDMI 2.0, HDCP2.2 compatible, and is backward compatible to the
earlier versions;
Transmits 4Kx2K@60Hz 4:4:4 signal up to 16.4 feet (5m) via HDMI port;
Provides powerful EDID management, built-in EDID can be invoked via DIP
switcher on rear panel, RS232 command or web-based GUI;
Controllable via front panel button, IR, RS232, TCP/IP or web-based GUI;
LCD screen shows real-time I/O connection status;
Convenient firmware upgrade through Micro USB port;
Easy installation with rack-mounting design.
1.3 Package List
1 x MUK44A 2 x Mounting ears
6 x Screws 4 x Plastic cushions
1 x RS232 cable (3-pin to DB9) 1 x IR receiver
1 x IR remote 1 x Power adaptor(24VDC 1.25A)
1 x User manual
Confirm if the product and the accessories are all included, if not, please contact
with the dealers.

ALFATRON ALF-MUK44A-N
2
2. Panel Description
2.1 Front Panel
Figure 2- 1 Front Panel
No. Name Description
① FIRMWARE Micro USB port for updating firmware.
② Power Indicator
Illuminates red when power on;
Turns green in standby mode;
Blinks red when upgrading.
③ IR sensor Built-in IR sensor, receive IR signal sent from IR
remote.
④ LCD Screen Displays real-time operation status.
⑤ INPUT selector
button
Total 4 input selector buttons, press one of buttons to
switch input source.
⑥ OUTPUT selector
button
Total 4 output selector buttons, press the buttons to
select output channel.

ALFATRON ALF-MUK44A-N
3
2.2 Rear Panel
Figure 2- 2 Rear Panel
No. Name Description
① INPUTS HDMI input ports, 4 in total, connect with HDMI
sources.
② OUTPUTS
SPDIF: audio output ports for de-embedded HDMI
audio, 4 in total.
HDMI: 4 in total, connect with HDMI displays.
③ CONTROL
EDID: 4-pin EDID DIP switchers to set EDID data, “1”
stands for “On”, “0” stands for “Off”. Refer to 4.2 EDID
Configurarion for more detials.
RS232: Serial control port, connect with control device.
IR IN: Connects with external IR receiver for using the
IR remote to control the Matrix Switcher.
TCP/IP: Connect control PC for TCP/IP control.
④ DC 24V Connect with 24VDC 1.25A power adaptor.
⑤ Ground Connect to ground.
Pictures shown in this manual are for reference only.
1
2
3
4
ON DI P
IN PU TS
OU TP UTS
CO NT ROL
SPD IF
SPD IF
SP DI F
SP DI F
1 2 3
4
1 42 3
On
Off
1 2 3 4
1
0
Tx R x
TCP /I PEDI D IR I N R S 232
DC 24 V
4
5
1
2
3

ALFATRON ALF-MUK44A-N
4
3. System Connection
3.1 Usage Precautions
1) System should be installed in a clean environment with prop temperature and
humidity.
2) All of the power switches, plugs, sockets and power cords should be insulated.
3) All devices should be connected before power on.
3.2 Connection Diagram
Figure 3- 1 Connection diagram
3.3 Connection Procedure
Step1. Connect HDMI sources (e.g. DVD/PS4/Laptop) to HDMI input ports with HDMI
cables;
Step2. Connect HDMI displays (e.g. HDTV/Projector) to HDMI output ports with HDMI
cables;
Step3. Connect speakers/ amplifiers to the SPDIF audio outputs with Toslink cables;
Step4. Connect the RS232 port of control device (e.g. Central Control System, PC) and
MUK44A to enable serial control;
Step5. Insert an IR receiver to the IR IN port to control this switcher via IR Remote;
Step6. Connect the TCP/IP port of control device (e.g. Laptop) and MUK44A to enable
TCP/IP control;
Step7. Plug a 24VDC power adapter to the DC 24V power port.
1
2
3
4
ON DIP
IN PU TS
OUT PUTS
CO NT RO L
SP DIF
SPD IF
SPD IF
SP DIF
1 2 3
4
1 42 3
On
Off
1 2 3 4
1
0
Tx Rx
TCP /I P
EDI D IR IN R S23 2
DC 12 V
Spea ker
DVD La p top HDTV P ro j ector
HD MI:
IR Contr ol:
RS232:
Et h er net:
Au dio:
Cent r al C ont ro l System
Ro uter
La pto p

ALFATRON ALF-MUK44A-N
5
1) When connecting to HDMI2.0 sources, make sure the HDMI cable is compliant with
HDMI2.0 to ensure reliable transmission;
2) Connect amplifiers that are capable to decode HDMI audio to the SPDIF ports, or
there will be no output on the amplifiers.
3.4 System Applications
As its good performance in control and transmission, the MUK44A can be widely used
in computer realm, monitoring, large screen displaying, conference system, television
education and bank securities institutions etc.
Tabla de contenidos
Otros manuales de Conmutador de matriz de ALFAtron

ALFAtron
ALFAtron MUH88TP-N Manual de usuario

ALFAtron
ALFAtron ALF- MUH44E Manual de usuario

ALFAtron
ALFAtron ALF-MMX6464A-N Manual de usuario

ALFAtron
ALFAtron ALF-MUK44N Manual de usuario

ALFAtron
ALFAtron ALF-MUH88TP-N Manual de usuario

ALFAtron
ALFAtron ALF-MUK88A-N Manual de usuario

ALFAtron
ALFAtron ALF-MUH88E Manual de usuario

ALFAtron
ALFAtron ALF-MUH88A-N Manual de usuario

ALFAtron
ALFAtron ALF-MUH44A-RS Manual de usuario

ALFAtron
ALFAtron ALF-MMX88A-N Manual de usuario


















