Akytec MSD200 Manual de usuario

MSD200_3-EN-120596-1.1
© All rights reserved
Subject to technical changes and misprints
akytec GmbH - Vahrenwalder Str. 269 A - 30179 Hannover - Germany Tel.: +49 (0) 511 16 59 672–0 - www.akytec.de
MSD200
Data Logger
User guide

1
akytec GmbH - Vahrenwalder Str. 269 A - 30179 Hannover - Germany Tel.: +49 (0) 511 16 59 672–0 - www.akytec.de
Contents
1. Introduction..........................................................................................................................3
1.1. Terms and abbreviations ...............................................................................................3
1.2. Symbols and key words.................................................................................................3
1.3. Intended use ................................................................................................................3
1.4. Improper use................................................................................................................3
1.5. Limitation of liability.......................................................................................................3
1.6. Safety ..........................................................................................................................4
2. Overview ..............................................................................................................................5
2.1. Basic features ..............................................................................................................5
2.2. Design .........................................................................................................................5
2.3. Control elements ..........................................................................................................6
3. Specifications ......................................................................................................................7
3.1. Specification tables.......................................................................................................7
3.2. Galvanic isolation .........................................................................................................8
3.3. Operating conditions .....................................................................................................8
4. MSD200 Configurator .........................................................................................................10
4.1. User interface.............................................................................................................10
4.2. MSD200-PC connection.............................................................................................. 11
4.2.1. RS-232 connection type.....................................................................................12
4.2.2. Modem connection type.....................................................................................12
4.2.3. Connection control ............................................................................................13
4.3. Channels ...................................................................................................................13
4.4. File Manager ..............................................................................................................15
4.5. View data ...................................................................................................................16
4.6. Settings .....................................................................................................................17
4.6.1. RS2 settings .....................................................................................................17
4.6.2. Digital signature ................................................................................................19
4.6.3. Common settings ..............................................................................................20
4.6.4. Date and Time ..................................................................................................20
4.6.5. Scheduled logging.............................................................................................20
4.7. Analog inputs .............................................................................................................21
5. Memory card ......................................................................................................................22
5.1. Memory card replacement ...........................................................................................22
5.2. Log file.......................................................................................................................22
5.3. Memory card synchronization ......................................................................................23
6. Installation .........................................................................................................................24
6.1. Mounting....................................................................................................................24
6.2. Wiring ........................................................................................................................24
6.3. RS485 network...........................................................................................................26
6.4. Quick replacement......................................................................................................26
7. Maintenance.......................................................................................................................27
8. Transportation and storage ................................................................................................28
9. Scope of delivery................................................................................................................29
Appendix A. Modbus application ...........................................................................................30

1 Introduction
3
akytec GmbH - Vahrenwalder Str. 269 A - 30179 Hannover - Germany Tel.: +49 (0) 511 16 59 672–0 - www.akytec.de
1 Introduction
This manual describes functionality, configuration, operating and installation of data logger MSD200,
hereinafter referred to as device or logger.
1.1 Terms and abbreviations
–CSV – plane text format designed for tabular data representation, used in the device to create log
files on a memory card, can be opened in MS Excel.
–Modbus – application layer messaging protocol for client/server communication between devices
connected on different types of buses or networks, originally published by Modicon (now
Schneider Electric), currently supported by an independent organization Modbus-IDA (www.
modbus.org).
–MSD200 Configurator – configuration software for MSD200, hereinafter referred to as
configurator or program.
1.2 Symbols and key words
WARNING
WARNING indicates a potentially dangerous situation that could result in death or
serious injuries.
CAUTION
CAUTION indicates a potentially dangerous situation that could result in minor
injuries.
NOTICE
NOTICE indicates a potentially dangerous situation that could result in damage to
property.
NOTE
NOTE indicates helpful tips and recommendations, as well as information for efficient
and trouble-free operation.
1.3 Intended use
The device has been designed and built solely for the intended use described here, and may only be
used accordingly. The technical specifications contained in this document must be observed.
The device may be operated only in properly installed condition.
1.4 Improper use
Any other use is considered improper. Especially to note:
– The device may not be used for medical appliances applied to maintain human life or health, its
control or other effect on them.
– The device may not be used in explosive environment.
– The device may not be used in atmosphere in which there are chemically active substances.
1.5 Limitation of liability
Our company does not bear any responsibility with respect to breakdowns or damages caused by
using the product in a manner other than described in the Manual or in violation of the current
regulations and technical standards.

1 Introduction
4
akytec GmbH - Vahrenwalder Str. 269 A - 30179 Hannover - Germany Tel.: +49 (0) 511 16 59 672–0 - www.akytec.de
1.6 Safety
WARNING
Ensure the mains voltage matches the voltage marked on the nameplate.
Ensure the device is provided with its own power supply line and electric fuse.
NOTICE
De-energize the device before working on it.
Switch on the power supply only after completing all works on the device.
NOTICE
Supply voltage may not exceed 33 V. Higher voltage can damage the device.
If the supply voltage is lower than 20 V DC, the device cannot operate properly but will
not be damaged.
NOTICE
If the device is brought from a cold to a warm environment, condensation may form
inside the device. To avoid damage to the device, keep the device in the warm
environment for at least 30 minutes before powering on.

2 Overview
5
akytec GmbH - Vahrenwalder Str. 269 A - 30179 Hannover - Germany Tel.: +49 (0) 511 16 59 672–0 - www.akytec.de
2 Overview
MSD200 is intended for data monitoring and logging in industrial automatic control systems.
The device can operate as Master or Slave via Modbus RTU / ASCII or AKYTEC protocol over
RS485 interface.
The device can be configured with MSD200 Configurator software (free) over USB or RS485
interface (Sect. 4.2). The software can be downloaded from our homepage akYtec.de.
2.1 Basic features
– 4 analog inputs 0-5 mA, 0-20 mA or 4-20 mA.
– Scaling of measured value.
– RS485 (RS1) and USB interfaces to connect to PC.
– RS485 (RS2) interface to connect to other devices in Modbus network.
– Master or Slave in Modbus network.
– Monitoring of data received from other devices via Modbus over RS485 interface.
– Logging and storing the received data to a memory card in a CSV file.
– Remote access over external modem.
–MSD200 Configurator software provides the device configuration and visual tools for process
data analyzing.
– Real-time clock.
– 4 status indicators.
2.2 Design
The device is designed in a plastic enclosure for DIN-rail mounting (Sect. 6).
Fig. 2.1 Front and side views

2 Overview
6
akytec GmbH - Vahrenwalder Str. 269 A - 30179 Hannover - Germany Tel.: +49 (0) 511 16 59 672–0 - www.akytec.de
2.3 Control elements
Four LEDs and two DIP switches are on the front panel.
Table 2.1 DIP switches
DIP
switch State Description
FACT
Off RS1 interface parameters (device address and baud rate) are set to user
settings
On
RS1 interface parameters are reset to default:
Device address = 16
Baud rate = 9.6 kbit/s
ARCH
Off Stop data logging
On Start data logging
Table 2.2 LEDs
LED Color State Description
PWR
—Off Supply voltage off or outside the permissible range
Green On Supply voltage inside the permissible range
RS1
—Off No data transmission over RS1 or USB
Green Flashing RS1 or USB with user settings, data transmission
in progress
Yellow
On RS1 or USB with default settings
Flashing RS1 or USB with default settings, data
transmission in progress
RS2
—Off No data transmission over RS2
Green
On Interval between data packets
Flashing Data packet received over RS2
Yellow On Interval between data packets, query cycle
exceeded, no timeout
Red On Interval between data packets, timeout
SD
Red
On No memory card, data stored to the built-in flash
memory
Flashing Data loss, memory card or built-in flash memory is
full
Green
On Logging paused, memory card can be removed
Flashing Logging in progress, memory card inserted and
CANNOT be removed
Yellow On Memory card inserted, logging stopped

3 Specifications
7
akytec GmbH - Vahrenwalder Str. 269 A - 30179 Hannover - Germany Tel.: +49 (0) 511 16 59 672–0 - www.akytec.de
3 Specifications
3.1 Specification tables
Table 3.1 General specification
Characteristic Value
Power supply 24 (20…33) V DC
Appliance class III
Power consumption, max. 5 W
Interfaces 2x RS485 (RS1, RS2); 1x USB
Dimensions (with terminal blocks) 23 х 109 х 120 mm
Weight Approx. 150 g
Table 3.2 Analog inputs
Characteristic Value
Quantity 4
Input signal 0-5 mA, 0-20 mA, 4-20 mA
Sampling time 100 ms
Basic accuracy ±1.0%
Input resistance 133 Ω
Galvanic isolation between inputs None
Table 3.3 Logging
Characteristic Value
Log channels 64
Dataset size (per channel), max. 20 Byte
Memory card type SD, SDHC, microSD
Memory card capacity, max. 32 GB
Memory card fie system FAT32
File type *.CSV
Logging cycle 1…65535 s
Backup battery CR2032
Backup time 2 years

3 Specifications
8
akytec GmbH - Vahrenwalder Str. 269 A - 30179 Hannover - Germany Tel.: +49 (0) 511 16 59 672–0 - www.akytec.de
Table 3.4 RS485 interfaces
Characteristic Value
RS1 (PC) Operation mode Slave
Protocol Modbus RTU
RS2 (DEV)
Operation mode Master, Slave, Slave Ext, Spy*
Protocol Modbus RTU, Modbus ASCII, AKYTEC
Baud rate 1.2…115.2 kbit/s
NOTE
* With AKYTEC protocol only
Table 3.5 USB interface
Characteristic Value
Type USB 2.0
Transport layer protocol CDC
Application layer protocol Modbus RTU
Baud rate 79 kB/s
Cable type USB A/B
3.2 Galvanic isolation
The device has 4 potential groups:
– 24 VDC power supply;
– Analog inputs, USB interface;
– RS1 interface;
– RS2 interface.
Galvanic isolation from each group to chassis 500 V AC / 1 min
Galvanic isolation between groups 500 V AC / 1 min
3.3 Operating conditions
The module is designed for natural convection cooling. It should be considered when choosing the
installation site.
The following environment conditions must be observed:
– clean, dry and controlled environment, low dust level;
– closed non-hazardous areas, free of corrosive or flammable gases.

3 Specifications
9
akytec GmbH - Vahrenwalder Str. 269 A - 30179 Hannover - Germany Tel.: +49 (0) 511 16 59 672–0 - www.akytec.de
Table 3.6 Operating conditions
Condition Permissible range
Ambient temperature -10…+55°C
Transportation and storage -15…+55°C
Relative humidity Up to 80% (at +25°C, non-condensing)
Altitude Up to 2000 m ASL
IP Code IP20
EMC immunity Conforms to IEC 61000-6-2
EMC emission Conforms to IEC 61000-6-4
Otros manuales para MSD200
1
Tabla de contenidos
Otros manuales de Registrador de datos de Akytec