This document contains the operating instructions for the AKIM GPRS-22 modem.

ii
i
CONTENTS
INTRO....................................................................................................................................1
1. TECHNICAL SPECIFICATIONS .....................................................................................3
2. USING INSTRUCTIONS.................................................................................................4
2.1. MODEM SETUP ......................................................................................................5
2.2. MODUL INFO...........................................................................................................7
3. MODEM START UP .......................................................................................................9
3.1 INFORMATIONS ABOUT LCD MESSAGES..........................................................10
3.1. SMS.......................................................................................................................11
3.2. MESSAGE TYPES SENDED BY MODEM.............................................................11

iii
FIGURES TABLE
Fig-1: GPRS/GSM Modem Overview..................................................................................... 1
Fig-2: Menu........................................................................................................................... 4
Fig-3: TKeypad...................................................................................................................... 5
Fig-4: PC1 IP Number ........................................................................................................... 5
Fig-5: Tel No Screen ............................................................................................................. 5
Fig-6: PC1 PORT No Screen................................................................................................. 5
Fig-7: ‘GSM PORT No Screen............................................................................................... 6
Fig-8: ‘GSM STATION Screen............................................................................................... 6
Fig-9: ‘SEND PERIOD’ Screen.............................................................................................. 6
Fig-10: Control Bits................................................................................................................ 6
Fig-11: ‘APN NAME’ .............................................................................................................. 7
Fig-12: ‘USER NAME’ ........................................................................................................... 7
Fig-13: ‘PASSWORD’ ........................................................................................................... 7
Fig-14: Serial Number ........................................................................................................... 7
Fig-15: Model No................................................................................................................... 8
Fig-16: Manufacturer Name................................................................................................... 8
Fig-17: Version Number Screen ............................................................................................ 8
Fig-18: Imei Number Screen.................................................................................................. 8
Fig-19: Initial Screen of LCD Display..................................................................................... 9
Fig-20: ’OKEY’ Message ....................................................................................................... 9
Fig-21: ’EROR-2’ Message.................................................................................................... 9
Fig-22: ’OKEY-2’ Message.................................................................................................... 9
Fig-23: ‘! SERVER !’ Message..............................................................................................10
Fig-24: Message Received by Modem .................................................................................11
Fig-25: PC-ToConnect Screen..............................................................................................11

4
Intro
Akim GPRS modem is produced in 3 different models. Designed for Akim PLV, Akim
Liminigraf and other Akim Data logger devices. GPRS modems have features such as SMS
sending, receiving, TCP / IP connection (Server / Client) and Data call. These features can
work selectively. When a data call and TCP / IP call are made, the modem automatically
makes the transparent connection with the logger devices. It does not interfere with the
exchange of information between the device and the server / client computer. Akim GPRS
modem is designed to respond to any customer requests. Akim GPRS modem can be used
in other logger devices thanks to its functional and transparent connection capability. General
view of the device is shown in Figure-1.
Figure-1: GPRS/GSM Modem Overview
The GPRS modem provides a transparent connection to the server computer when it
is running as a client. The modem remains connected to the computer as long as the
computer is disconnected. Access to all information on the Logger device is provided. The
GPRS modem automatically disconnects if the data exchange is not carried out within 5
minutes during which the GPRS modem remains connected.
Thanks to the modem's SMS receiving and sending, instantaneous values from
Logger devices can send SMS to defined phone numbers.
When alarm status information is received from Logger devices, SMS can be sent to
three phone numbers registered on the GPRS modem (see Figure-5 on page 6).
Modem Status LED
Network data
sending status LED
Rs-232 Conn.
Mounting Screw
Antenna
3x16 Char. LCD
Display
Keypad
8…24 V DC
Power Conn.
On/Off Button

5
The GPRS modem has a reset feature via SMS. The SMS message receiving and
sending feature is optional, details on this can be viewed on page 6.
The GPRS modem has the ability to connect with TCP / IP and to respond to data
calls. Apart from the fact that these two features can be used at the same time, only the
ability to answer data calls can be used alone. If there is no internet connection in the GPRS
modem, the device can answer data calls and connect to Logger devices via GSM modem.
The GPRS modem checks a network every minute. In the network control, the
antenna power, internet quality and network connection controls can be done automatically.
During this check, if the modem is out of server mode, it tries to remain active by trying to
enter the server mode again. If the Modem is disconnected from the Network or the Internet,
the modem automatically restarts itself. The modem performs this check 3 times. If all three
controls have no internet connection or network connection, the modem switches off and on
automatically every six hours. This cycle continues until the internet and network connection
is reached. The modem has the ability to turn itself off and on every 24 hours.

6
1.
TECHNICAL SPECIFICATIONS
Power Supply: 8 … 28Volt DC Peak 1,5A
Standbye: 25mA
Power off: 62uA
Idle (registered, power saving): 1.5mA @ DRX=9
Dedicated mode: <240 mA @ max power level
GPRS class 10: <420 mA @ max power level
RS232 Port : 1 Conn.
SMS Receiving and Sending
Quad Band EGSM - 850/900/1800/1900MHz
Output Power
Class 4 (W) @ 850/900MHz
Class 1 (1W) @ 1800/1900MHz
Control via AT commands according to 3GPP TS 27.005, 27.007 and Telit Custom
AT commands
Serial port multiplexer 3GPP TS 27.010
SIM access profile
TCP/IP stack access via AT commands
Sensitivity
107 dBm (tpy.) @ 850/900MHz
106 dBm (typ.) @ 1800/1900MHz
Power consumption (typical values)
Extended temperature range
-4o to +80°C (operational)
-40 to +85°C (storage temperature)
Point-to-point mobile originated and mobile terminated SMS
Concatenated SMS supported
SMS cell broadcast
SMS Text mode
SMS over GPRS
Circuit Switched Data Transmission
GPRS Class 10
Mobile station class B
Coding scheme 1 to 4
Network LED support
Embedded TCP/IP stack, including TCP, IP, UDP, SMTP, ICMP and FTP protocols

7
2.
USING INSTRUCTIONS
The energy required by the GPRS / GSM modem device is 8…28 volts DC. In order to be
connected to the grid, a high gain antenna or a yagi antenna is required. When the modem is
connected to the appropriate data loggers via the RS232 cable, the device is ready for
operation.
There are 3 section on the Menu(Fig-2)
1-MODEM SETP: Necessary information to install the modem and connect to the internet are
entered and displayed in this section. It is the section where the APN name, user name and
password and setup flags and phone numbers are processed and seen.
2-MODEM INFO: Gives information about the module. It contains information such as serial
number of module, imei number, version number.
3-MODEM RST: Used to turn the module off and on. When this menu is entered, it turns on the
modem if the module is turned off, if the modem is off, it turns the module off and on again,
and starts re-installing the modem.
Detailed information about these menus is described in detail with figures below.
Fig-2: Menu
If the enter button is pressed while the modem is on, the menu in figure 2 opens.

8
2.1.
Modem Setup
When the enter button is pressed from the main menu, the display in Figure-4 is displayed.
When the down key is pressed, you can navigate through the menu, change the changeable
parameters, and only observe the parameters which are not changeable. You can change
the value at the cursor position. An overview of the keypad is shown in Figure-3.
UP Button: Used to change values. Pressing this key step by step increases the values.
Down Button: Used to change values. İt is work specific menus(letter changing etc.)
Enter Button: It is used to save the desired parameter value, to move to the other menu and
skip the line. When you change the parameter value, it comes to the last column of the value
and pressing the Enter key for a long time saves the parameter value than move on next sub
menu. After moving on the next menu it means the values you have changed are saved.
Back Button: It is used to navigate menus. When you push the button you can move on the
next menu or sub menu.
Down Button
Up Button
Enter Button
Fig-3: Keypad
Back Button

9
Fig-4: PC1 IP Number
Fig -5: Tel Number Screen
Fig -6: ‘PC1 PORT NO’ Screen
The IP address of the server computer that will be
connected to PC1 IP and PC2 IP is entered in IPv4
format. It is used to send the alarm information and
instant information from the logger to the desired
time interval. The IP is entered between
000,000,000,000 …255,255,255,255.
Three different phone number can be entered in Tel1
No, Tel2 No and Tel3 No sections. Instant values are
periodically sent to these numbers. Also The alarm
information from the Logger device is sent to the
persons whose phone numbers are written here.
Enter the TC / IP Port number to be connected to two
server computers, ir PC1 PORT NO IP and ıla PC2
PORT NO ‘. Enter a value between 0 and 65535.
Tabla de contenidos
Manuales populares de Módem de otras marcas

US Robotics
US Robotics 3453C Manual de usuario

MaxTech
MaxTech Plug & Play Internal Voice/FAX/Data/SVD... Manual de usuario

Zte
Zte MF823 Manual de usuario

Four-Faith
Four-Faith F1403 Manual de usuario

Sierra Wireless
Sierra Wireless AIRLINK MP595W Manual de usuario

Gemtek
Gemtek WiMAX WIXFBR-103 Manual de usuario