SP2+ Introduction Manual
Copyright © 2016, AKCP

SP2+ Introduction Manual
- 2 -
Table of Contents
Introduction ................................................................................................................................................... 3
Port assignment information for SP2+ units..............................................................................................4
LED information for SP2+ units...................................................................................................................5
Reset button functions for SP2+ units........................................................................................................6
Setting up the unit’s IP address ..................................................................................................................7
SP2+ Web UI Walkthrough...........................................................................................................................8
Summary page .................................................................................................................................9
Graph feature....................................................................................................................... 13
System page.....................................................................................................................................15
General & Language ...........................................................................................................17
Date/Time.............................................................................................................................19
Network................................................................................................................................20
Modem..................................................................................................................................21
VPN.......................................................................................................................................23
SMTP ....................................................................................................................................24
SNMP & SNMPv3.................................................................................................................26
Server Integration ...............................................................................................................27
Password Checking............................................................................................................28
Maintenance ........................................................................................................................29
Heartbeat Messages ...........................................................................................................30
License Management & About........................................................................................... 31
Sensors page....................................................................................................................................34
General options for all sensors......................................................................................................35
Example sensor configuration .......................................................................................................39
Temperature/Humidity Sensor...........................................................................................40
Relay Sensor ....................................................................................................................... 43
Firmware upgrade through the Web UI..........................................................................................47

SP2+ Introduction Manual
- 3 -
Introduction
In this manual, we’ll cover the main features and basic configuration of the SP2+ and the setup of
notifications and the explanation of events will be in another manual.
What is the SP2+ and Thermal Map?
The SP2+ is a high speed, accurate, intelligent monitoring device, featuring a completely embedded
host and operating system. The SP2+ is a complete redesign of the world’s best-selling
environmental monitoring platform, 3 years in the making with all new hardware and software.
We’ve combined the low cost and simplicity of use of the SP2, along with many advanced features of
our securityProbe platform.
The thermal map combines 4 sensors into one sensor port on the SP2+, specially designed to
monitor the air entering and leaving a computer rack. The Thermal Rack Map is performed from the
AKCess Pro Server using the Thermal Sensor connected to the SP2+. The Thermal Map Sensors
monitor the temperature and humidity at different points of the rack.
SP2 + Features:
●IP based, including SNMPv3, HTTPS, VPN
●Send encrypted SNMP Trap and Email Notifications
●Supports 4 Intelligent Sensors or up to 20 Dry Contacts
●Optional cellular modem with external antenna
●Notification Wizards
●Front and Rear Thermal Mapping for any server cabinet
●Low Cost Daisy Chained Temperature sensors
●Optional Expansion Module connectivity
●Virtual Sensors
●Patented Fire Suppression feature
●AKCP Swing Handle Lock support
Important note: Some of the pictures shown in this manual might not represent the actual Web UI of
the unit; this is because we are constantly working on improving the firmware. Please provide us with
feedback if you have any issues configuring your unit.

SP2+ Introduction Manual
- 4 -
Port assignment information for SP2+ units
Port numbering starts from the power connector on the unit: the closest port to the power connector is
Port 1 and closest to the Ethernet interface is Port 4.
You may connect AKCP intelligent sensors to any available ports.
Important note: If you're using analog pins on the sensor ports (with manually on-lined DCV sensors,
and pin 7 of the RJ45 connector) make sure that the voltage doesn't exceed 3 Volts. Otherwise you
can damage the unit!

SP2+ Introduction Manual
- 5 -
LED information for SP2+ units
Power/Ethernet Link - Sensor 1 - Sensor 2 - Sensor 3 - Sensor 4
The Power/Ethernet LED will become red if there’s no network connection, and blinking green
(according to LAN activity) when the connection is normal.
For sensor LEDs (green):
Off = offline
On = online and normal
Slow blinking = Warning status
Fast blinking = Critical and Error status

SP2+ Introduction Manual
- 6 -
Reset button functions for SP2+ units
There are specific commands you can send to the unit by holding the Reset button for a specified
amount of time.
You’ll have to use something sharp, such as a straightened paperclip to be able to press Reset.
Commands:
Time to hold
Action
3..7 sec
Reboot
7..12 sec
Web UI password reset
12..17 sec
Serial flash erase (DB erase without factory reset, the system configuration is kept)
17..25 sec
Reset to factory defaults (serial flash erase + config erase)

SP2+ Introduction Manual
- 7 -
Setting up the unit’s IP address
Very Important Note: The unit’s ship with the passwords enabled. The default log in for the web
interface is Username: admin Password: public
Every unit is shipped with the default IP address of 192.168.0.100
First we will go through the process of changing this IP address to fit your own network configuration.
Note: In some cases your computer might not be able to connect to this default IP address. In this
situation you either need to:
a) add this IP your computers routing table or
b) add a secondary IP address to the LAN card to allow access to the unit.
See below how to setup these.
Ensure the following items are available to you before starting:
- RJ45 CAT5 crossover cable with RJ45 male connection
- A PC with Ethernet card or LAN socket, logged in with Administrator rights
1) Connect the unit via the Ethernet port of the unit to your computers LAN or Ethernet port with a
CAT5 crossover cable.
2) Open a web browser and type the default IP address, hit enter.
You’ll be presented by the Summary page.
Go to the System/Network page to change the network settings (see below in this manual).
Once you have assigned the new IP address use the “ping” command to test the unit’s reply.

SP2+ Introduction Manual
- 8 -
How to add a manual route to the computer’s routing table?
Open an Administrator Command Prompt (CMD) window and type:
route add 192.168.0.100 10.1.1.20
Where 10.1.1.20 is the IP address of the Ethernet interface on the PC that the unit is plugged into
with the crossover cable.
Note: If you do not receive an 'OK!' message then a parameter was wrong or missing.
The route is not persistent (removed upon rebooting), but you can also delete it with the
route delete 192.168.0.100 command.
How to add a secondary IP address to the computer’s LAN card?
You can do this via the GUI by opening the LAN connection’s properties:
Or open an Administrator Command Prompt (CMD) window and type:
netsh interface ipv4 add address “Local Area Connection”192.168.0.2
255.255.255.0
The above command adds the IP Address 192.168.0.2 (with Subnet Mask 255.255.255.0) to the
connection titled “Local Area Connection”.
You will then be able to connect to the unit with its default IP.
Note: The secondary IP address is permanent for the LAN connection; don’t use it if you only need it
once. Instead use the routing table method above.

SP2+ Introduction Manual
- 9 -
SP2+ Web UI Walkthrough
Menu navigation
With newer firmware (after 1.0.3074), the Web UI and the menu structure has been changed on all
SP+ family devices.
To open the menu, click on the three horizontal lines in the upper left corner:

SP2+ Introduction Manual
- 10 -
This will bring up the full menu for navigation.
Depending on the device, you might see additional menu items, such as Power.
Tabla de contenidos
Otros manuales de Instrumento de medición de AKCP

AKCP
AKCP FreeRADIUS SP+ Manual de usuario

AKCP
AKCP SPX+ Manual de referencia

AKCP
AKCP sensorProbe2 Manual de usuario

AKCP
AKCP sensorProbe8 Manual de usuario

AKCP
AKCP Inline Power Meter AC Manual de usuario

AKCP
AKCP ILPM Manual de usuario

AKCP
AKCP SP1+ Manual de instrucciones

AKCP
AKCP PMS120-CT50 Manual de usuario

AKCP
AKCP SP1+ Manual de usuario
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario