DoorProtect Plus is a wireless opening, shock, and tilt detector, that operates
within the Ajax security system, connecting via the protected radio
protocol. Is used inside premises. The communication range is up to 1,200 m
line of sight. DoorProtect Plus can operate up to 5 years from a pre-installed
battery and capable to detect more than one million openings.
The user can congure the detector via the for iOS, macOS, Windows,
or Android. The app noties the user of all events through push notications,
SMS, and calls (if activated).
DoorProtect Plus does not support connecting via the or
integration modules.
The Ajax security system can be connected to a central monitoring station of a
security company.
Jeweller
Ajax app
Ajax uartBridge Ajax ocBridge
Plus

Functional Elements
Operating Principle
DoorProtect Plus consists of two parts: the detector and the constant magnet.
The detector is equipped with the sealed contact reed relay, built-in
accelerometer, and socket for a third-party wired detector.
Buy opening detector with shock and tilt sensor DoorProtect Plus
1. DoorProtect Plus
2. Big magnet
3. Small magnet
4. LED indicator
5. SmartBracket attachment panel (perforated part triggers the tamper button
in case of any attempt to tear off the detector from the surface)
6. External detector connection socket
7. QR code
8. Device switch
9. Tamper button

Attach the detector to the door frame, while the magnet can be attached to the
moving wing or sliding part of the door. If the sealed contact reed relay is within
the coverage area of the magnetic eld, it closes the circuit, which means that
the detector is closed. The opening of the door pushes out the magnet from the
sealed contact reed relay and opens the circuit. In such a way, the detector
recognizes the opening.
The DoorProtect Plus set includes two constant magnets. The small one works
at a distance of 1 cm, and the big one — up to 2 cm.
The detector can be positioned horizontally. If there is no need to detect
opening, use only the detector part (without magnets) and disable the primary
detector in the settings.
The accelerometer detects shocks and vertical deviation relative to the initial
position of more than 5°. DoorProtect Plus can be installed on windows,
including dormer windows, and the system can be armed when they are slightly
open (disable the primary detector in the settings рreviously).
If triggered, DoorProtect Plus immediately transmits the alarm signal to the hub,
activating the sirens and notifying the user and security company.
Connecting
Before starting connection
1. Following the hub user guide, install the . Create the account, add
the hub, and create at least one room.
Ajax app

Only users with administrator rights can add the device to the hub.
How to connect the detector to the hub
2. Switch on the hub and check the internet connection (via Ethernet cable
and/or GSM network).
3. Make sure that the hub is disarmed and does not update by checking its
status in the Ajax app.
1. Select Add Device in the Ajax app.
2. Name the device, scan or type the QR code (located on the detector body
and packaging), and select the location room.
3. Tap Add — the countdown will start.
4. Switch on the device.

For detection and pairing to occur, the detector should be located within the
coverage area of the wireless network of the hub (at a single protected object).
The connection request is transmitted for a short time: at the moment of
switching on the device.
If the device failed to pair (LED blinks once per second), switch it off for 5
seconds and retry. The detector connected to the hub appears in the list of
devices in the app. The update of the detector statuses in the list depends on
the device ping interval set in the hub settings (the default value is 36 seconds).
States
Parameter Value
Temperature
The temperature of the detector. The
temperature is measured on the processor and
changes gradually
Jeweller Signal Strength The signal strength between the hub and the
detector
Connection Connection status between the hub and the
detector
Battery Charge The battery level of the detector, displayed in
1. Devices
2. DoorProtect Plus

increments of 25%
Lid The tamper mode of the detector, which reacts
to the detachment of or damage of the body
Delay when entering, s
Entry delay (alarm activation delay) is the time
you have to disarm the security system after
entering the room
Delay when leaving, s
Delay time when exiting. Delay when exiting
(alarm activation delay) is the time you have to
exit the room after arming the security system
Routed Through ReX Displays the status of using the radio signal
range extender ReX
Primary Detector Indicates whether the opening sensor is active
Secondary detector Status of the external detector connected to
DoorProtect Plus
Always active Indicates whether the detector is always armed
Shock sensor Indicates whether the shock sensor is active
Tilt sensor Indicates whether the tilt sensor is active
Temporary Deactivation
Shows the status of the device: active,
completely disabled by the user, or only
notications about triggering of the device
tamper button are disabled
Firmware The detector rmware version
Device ID Device identier
Settings
What is delay when entering
What is delay when leaving
1. Devices
2. DoorProtect Plus
3. Settings

Setting Value
First eld Detector name, can be edited
Room Selecting the virtual room to which the device is
assigned
Delay when entering, s
Selecting delay time when entering. Delay when
entering (alarm activation delay) is the time you
have to disarm the security system after
entering the room
Delay when leaving, s
Selecting the delay time when exiting. Delay
when exiting (alarm activation delay) is the time
you have to exit the room after arming the
security system
Delays in Night mode
Delay turned on when using Night mode
Arm in Night mode
If actived, the detector switches to armed state
while Night mode is active.
Kept in mind that in , all active
sensor of the detector become armed. It is not
possible to arm only certain sensors of the
detector in Night mode (for example, only a tilt
sensor)
Alarm LED indication
Allows you to disable the ashing of the LED
indicator during an alarm. Available for devices
with rmware version 5.55.0.0 or higher
Primary Detector If setting is active, the DoorProtect Plus primary
detector reacts to opening/closing
External contact enabled If setting is active, the detector registers
external detector alarms
Shock sensor If active, shock-sensor will detect alarm after
What is delay when entering
What is delay when leaving
What is night mode
Night mode
How to nd the rmware version or
the ID of the detector or device?

more than one impact
Sensitivity Sensitivity level of the shock sensor
Ignore simple impact If active, the detector ignores single hit
Tilt sensor If active, sensor will detect tilt
Tilt Selecting the normal angle of the sensor. Above
this limit, the sensor detects an alarm
Tilt alarm delay The number of seconds from the moment the
sensor is tilted to the alarm
Always active When turned on, the detector is always armed
External Contact Type Selecting the type of
Time before alarm, sec
(available for roller shutter motion detector
only)
The time in seconds during which a given
number of impulses should be counted. This
time is counted after the rst impulse of the
detector.
Impulses before alarm
(available for roller shutter motion detector
only)
Number of detector impulses required to raise
an alarm
Alert with a siren if opening detected If active, and are
activated when opening detected
Alert with a siren if an external contact is open If active, HomeSiren and StreetSiren are
activated during an external detector alarm
Alert with a siren if shock is detected If active, HomeSiren and StreetSiren are
activated during a shock alarm
Alert with a siren if tilt is detected If active, HomeSiren and StreetSiren are
activated during a tilt alarm
Jeweller Signal Strength Test Switches the detector to the signal strength test
mode
Detection Zone Test Switches the detector to the detection area test
Attenuation test
Switches the detector to the signal fade test
mode (available in detectors with rmware
version 3.50 and later)
Temporary Deactivation Allows the user to disconnect the device
without removing it from the system.
Two options are available:
external wired
detector
HomeSiren StreetSiren

User Guide Opens the detector User Guide
Unpair Device Disconnects the detector from the hub and
deletes its settings
Indication
Event Indication Note
Switching on the detector Lights up green for about one
second
Detector connection to the Lights up continuously for a
few seconds
Alarm / tamper activation Lights up green for about one
second
Alarm is sent once in 5
seconds
Battery needs replacing
During the alarm, it slowly
lights up green and slowly
goes out
Replacement of the detector
battery is described in the
manual
Performance testing
The Ajax security system allows conducting tests for checking the functionality
of connected devices.
The tests do not start immediately but within 36 seconds by default. The
starting time depends on the ping interval (the paragraph on “Jeweller” settings
in hub settings).
Deactivate entirely — the device will not
execute system commands or participate in
automation scenarios, and the system will
ignore device alarms and other notications
Deactivate lid notications — the system will
ignore only notications about the triggering of
the device tamper button
Learn more about temporary
deactivation of devices
hub
Battery Replacement

Installing the Detector
The location of DoorProtect Plus depends on its remoteness from the hub, and
obstacles hindering the radio signal transmission: walls, oors, large objects
inside the room.
The device developed only for indoor use.
Check the Jeweller signal level at the installation location
If the signal level is low (one bar), we cannot guarantee the stable operation of
the detector. Take all possible measures to improve the quality of the signal. At
least, move the detector: even a 20 cm shift can signicantly improve the quality
of signal reception.
If the detector has low or unstable signal strength even after moving, use a
.
Do not install the detector:
Jeweller Signal Strength Test
Detection Area Test
Attenuation Test
ReX
radio signal range extender
1. outside the premises (outdoors);
2. nearby any metal objects or mirrors causing attenuation or screening of the
signal;
3. at any places with fast air circulation (air fans, open windows or doors);
4. inside premises with the temperature and humidity beyond the range of
permissible limits;
Otros manuales para DoorProtect Plus
1
Tabla de contenidos
Otros manuales de Sensor de seguridad de AJAX Systems

AJAX Systems
AJAX Systems MotionCam Manual de usuario

AJAX Systems
AJAX Systems StreetSiren Manual de usuario

AJAX Systems
AJAX Systems GlassProtect Manual de usuario

AJAX Systems
AJAX Systems DoorProtect Manual de usuario

AJAX Systems
AJAX Systems Hub Plus Manual de usuario

AJAX Systems
AJAX Systems DoorProtect Manual de usuario

AJAX Systems
AJAX Systems MotionProtect Outdoor Manual de usuario

AJAX Systems
AJAX Systems MotionCam Manual de usuario