Airtronic LT-700 Manual de usuario

LT-700
Stationary Terminal
Operating Manual

LT-700
Stationary Terminal
Operating Manual

We don’t deliver just our mobile Data Capturing Devices
with Standard Software...
but also develop to customers specific
•Applications for this Devices
•PC Applications
•Hardware
and advise you on
•Creating concepts for mobile and stationary data collection
•Queries surrounding Bar Code and RFID
•Hardware problems
Please consult us with your queries or problems at:
aitronic GmbH
Balhorner Feld 10
D-33106 Paderborn
Germany
Phone: +49 (0) 5251 29816-0
Fax: +49 (0) 5251 29816-40
Internet: http://www.aitronic.de
___________________________________________________________
Copyright aitronic GmbH, 2015
All Rights reserved, in particular all extracts which correspond to the
translation, the reprint and reproduction by copying or similar methods.
Delivery and technical changes are subject to change.

Content___________________________________________________________________ 1
____________________________________________________________________ aitronic
Connectors ............................................................................ 3
Designations.......................................................................... 4
Start Page............................................................................... 5
CONFIGURATIONS MANAGER............................................. 6
SERVER MENU....................................................................................................7
WEB-APPLICATION-SERVER.........................................................................8
MDE-SERVER...................................................................................................9
DNC-SERVER.................................................................................................10
NETWORK MENU..............................................................................................11
LT-700 Terminal LAN Settings .....................................................................11
LT-700 Router Administration......................................................................12
Login ...........................................................................................................13
Status..........................................................................................................14
System ........................................................................................................15
Network.......................................................................................................16
Logout.........................................................................................................16
Factory Default..................................................................................................17
Factory Default Settings ...............................................................................17
Resetting to Factory Default State...............................................................18
Deviating from the default Settings ................................................................18
WAN Interface with static IP Address..........................................................18
Setting up Wi-Fi Wireless (WWAN)..............................................................19
Main Operating Modes........................................................ 20
LAN-Mode..........................................................................................................20
WLAN Mode.......................................................................................................21

Content___________________________________________________________________ 2
____________________________________________________________________ aitronic
Services and Programs....................................................... 22
MDE (ai-mde).....................................................................................................22
Program Start.................................................................................................22
Output Format................................................................................................22
JSON ...........................................................................................................22
CSV..............................................................................................................23
NONE...........................................................................................................23
Offline Data Storage......................................................................................23
DNC (ai-dnc)......................................................................................................23
Program Start.................................................................................................23
Configuration.................................................................................................24
Open Data Port ..............................................................................................24
Close Data Port..............................................................................................24
Debug Control................................................................................................25
Heartbeat Control..........................................................................................25
Clear Data Port Buffer...................................................................................25
Status Query..................................................................................................26
Return Error/Message...................................................................................26
Return Status.................................................................................................27
Firmware Update of the LT-700.......................................... 28
By means of Firmware Image from SD Card..................................................28
Default Port Configuration.................................................. 29
Eliminating Errors ............................................................... 30
Technical Data..................................................................... 31

Connectors______________________________________________________________
____________________________________________________________________ aitronic
3
Connectors
ETHERNET LAN0(WAN) LAN/WAN
ETHERNET LAN1 LAN
USB A1/A2 Connector for external devices with USB Interface (e.g.
barcode scanner)
USB B USB Host Interface
MDE INPUT/OUTPUT RS-232 for connection of a MDE device
DNC RS-232 for connection of a DNC Machine
DC_IN 12V-24 V Power Supply
ETHERNET USB USB USB MDE DNC DC_IN
LAN0(WAN) LAN1 A1 A2 B INPUT/OUTPUT 12V-24V

Designations_____________________________________________________________
____________________________________________________________________ aitronic
4
Designations
LT-700 is the name for the entire device, containing the LT-700
Terminal and the LT-700 Router.
LT-700 Router consists essentially of the WIZnet module and is part of
the LT-700.
LT-700 Terminal essentially consists of the Linux computer and is part of
the LT-700.

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
5
Start Page
After a cold start of the LT-700, the web page, which is specified in the WEB
APPLICATION SERVER under URL, is displayed. By default, this is the page
https://www.aitronic.de/de/impressum:
Startseite
By holding down the key and pressing key F1 the CONFIGURTAIONS
MANAGERs login screen is called.

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
6
CONFIGURATIONS MANAGER
The buttons at the bottom of the CONFIGURATION MANAGER are assigned by
their respective position to the function keys F1 ... F5 which are located below the
display. On the following login page, for example, the following function keys can
be used as an alternative to the buttons:
START F1
LOGIN F5
Login-Seite
START Return to the Start Page
Password 1478963
LOGIN Calling the Menu Main Page
Menu Main Page
START Return to the Start Page
NETWORK Calling page NETWORK MENU
SERVER Calling page SERVER MENU
Software Version

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
7
SERVER MENU
SERVER MENU
<back Return to the Menu Main Page
WEB Calling page WEB-APPLICATION-SERVER
DNC Calling page DNC-SERVER
MDE Calling page MDE-SERVER
Connections to a web server, which determines the user interface of the device, to
a DNC server serving the communication of a serial interface and to an MDE
server, which is responsible for the storage and analysis of MDA data, can be
established.
Tabla de contenidos

















