Aimetis e3200 series Manual de usuario

English Deutsch Español Français Português Svenska
Aimetis
E3200 Series™
Physical
Security
Appliance
Installation and User Guide

English
Deutsch
Español
Français
Português
Svenska

1
English
Introduction
Aimetis E3200 Series™ Physical Security Appliance combines a purpose-built hardware appliance with
Aimetis Symphony™ video management & analytics software, creating a high performance intelligent
video surveillance platform for installations under 16 cameras. Its robust fanless design and flexible
installation options makes the E3200 Series an ideal solution for space constrained environments such as
small footprint retailers and harsh environments.
Figure 1: Hardware configuration example

2
English
Setup Process
1.
“Unpack the Box” on page 3
2.
“Connect the E3200 PSA to the Network” on page 5
3.
“Connect to Your E3200 PSA” on page 8
4.
“Install Symphony Client” on page 21
5.
“Configure the Video Management Software (VMS)” on page 23
6.
“Review Safety, Maintenance, and Support Information” on page 24
7.
“Mounting the E3200 PSA” on page 25
8.
“Appendix: Advanced Features” on page 27
Table 1: Passwords
Page Default Password
PSA
Log In
page
AimetisE3200
(Can be changed on
Password
page. See comment below.)
PSA
Password
page Type in a new password of your choice.
The specified password is used by this Web Administration wiz-
ard and also used to restrict direct access to the PSA device. This
password does not apply to any user within the Aimetis Sym-
phony software.
Symphony Client -
Register
Symphony Server
dialog box,
Username
,
Password
fields
Admin
,
Admin

Unpack the Box
3
English
Step 1: Unpack the Box
Your Aimetis
E3200 Physical Security Appliance (E3200 PSA)
package includes:
Note
: Keep the packing material in case you need to return the
E3200 PSA
for service.
Features
• E3200 Physical Security Appliance
• CD with Installation and User Guide, Symphony Client software
• Metal wall mounts and screws for wall mounting of unit (optional)
• Feet for flat placement of unit
• Power adapter and power cord
Table 2: E3200 Series Specifications
Model E3205 E3210
CPU Dual Core Atom1.66Ghz Dual Core Atom1.66Ghz
RAM 2GB 2GB
OS Windows 7 embedded Windows 7 embedded
Storage 500GB 1TB
Video Management Software Symphony Standard Symphony Standard
Camera Licenses Included 4 8
Max Cameras* 16 16
Ethernet 2xGbE 2xGbE
USB 4 4
Integrated Inputs/Outputs 4/4 4/4
Monitor Output DVI-D/VGA DVI-D/VGA
Extended storage With NAS With NAS
Video Analytics Ready* Yes Yes
ONVIF Yes Yes
Operating Temperature -5 to 45 degrees Celsius -5 to 45 degrees Celsius
Dimensions (mm) 268W X 174D X 44H 268W X 174D X 44H
Weight 2.5KG 2.5KG
Input Voltage 12VDC/5 A Max 12VDC/5 A Max
Compliance CE, FCC, RoHs CE, FCC, RoHs
Mounting Kit Wall mount included Wall mount included

Unpack the Box 4
English
*with license upgrade
Front Panel
Figure 2: Front panel - Aimetis logo on front panel of long side of unit
• USB (2 ports)
•On/Offswitch
Back Panel
Figure 3: Back panel
• VGA
• DVI-D
•Reset
• DIO
• USB (2 ports)
• LAN1
• LAN2
• DC-IN
Warranty 2 year 2 year
Table 2: E3200 Series Specifications (Continued)
Model E3205 E3210

Connect the E3200 PSA to the Network
5
English
Step 2: Connect the E3200 PSA to the Network
Note the following points:
1. This is a setup procedure to configure basic system settings such as a computer name, IP
address, time and time zone. Video management settings will be configured by
Symphony
Client.
2. Initial setup does NOT require a monitor, keyboard or mouse to be attached to the
E3200
PSA
. The
VGA
and
DVI-D
ports are for troubleshooting only.
3. The
E3200 PSA
will be configured using your Web browser once connected to your network.
Using LAN1 or LAN1 & LAN2
The
E3200 PSA
may be connected to a single network containing IP cameras and client computers. You
may use either the
LAN1
or the
LAN2
ports on the back panel. For convenience this guide will assume
LAN1
is used.
Figure 4: One network in use

Connect the E3200 PSA to the Network 6
English
The
E3200 PSA
may also be connected to two networks by using both the
LAN1
and
LAN2
ports on the
back panel. Using two separate networks could be required if the video traffic must be isolated from the
corporate network. The video will only traverse the corporate network if a user wishes to see video. Oth-
erwise no video will traverse the two networks.
Figure 5
shows a typical network layout when two net-
works are in use. It shows cameras are on a separate network from clients. This is not essential. They may
be mixed across two networks.
LAN1
and
LAN2
may be used interchangeably.
Figure 5: Two networks in use
Never connect the
LAN1
and
LAN2
ports to the same network.
Figure 6: Do NOT connect LAN1 and LAN2 to the same network

Connect the E3200 PSA to the Network
7
English
To perform initial setup:
1. Connect the
E3200 PSA
to the network with a twisted-pair cat.5 or cat.6 cable using
LAN1
on
the back panel.
2. Connect the power adapter to the
E3200 PSA
and press the power button on the front panel.
The power button will light up green and the hard disk activity indicator will flash as it boots.
3. Connect your computer to the network.
Ensure DHCP is enabled on your networking
adapter.
Figure 7: Back panel of E3200 PSA with LAN1 indicated
Figure 8: Front panel of E3200 PSA with power button indicated
• If a DHCP server is available on the network, the
E3200 PSA
will obtain an
IP address automatically.
• If no DHCP server is available, the
E3200 PSA
will assign itself an IP
address automatically using automatic private IP addressing. The
E3200
PSA
will be set to
169.254.x.y
(where
x.y
is the device’s unique identifier)
with a
subnet
of
255.255.0.0
.

Connect to Your E3200 PSA 8
English
Step 3: Connect to Your E3200 PSA
The Administration Wizard is normally run once only.
To run the Administration Wizard:
1. Load the CD into your computer. If the software does not start automatically use Windows
Explorer or My Computer to browse the contents of the CD and double-click
CDBrowser.exe
.
2. A window appears allowing you to select your preferred language.
3. The CD Menu appears with the
Start
tab active.
Figure 9: CD Menu - Start tab
4. Read the information and then click the
E3200 Setup
tab.
Tabla de contenidos
Idiomas:
Manuales populares de Sistema de seguridad de otras marcas

EDM
EDM Solution 6+6 Wireless-AE Manual de usuario

Highway Safety Group
Highway Safety Group EA401 Manual de usuario

Siren
Siren LED GSM Manual de usuario

Detection Systems
Detection Systems 7090i Instrucciones de montaje

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manual de usuario

Siemens
Siemens FDM273 Manual de usuario











