Aidcall Touchsafe Pro Manual de usuario

Doc No. FM5590 issue C Page 1
Touchsafe
®
Pro
Wireless Nursecall System
_________________________________________________________________________________________________
Call Logger V4.00a
Installation Guide
Aidcall operates a policy of continual product improvement and
reserves the right to modify the specification of its products.
If any variation to the details in this document are suspected please
contact Aidcall’s Technical Support.
Aidcall, a business unit of Legrand Electric Ltd
Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF.
T: +44 (0) 1670 357 431 www.aidcall.co.uk
________________________________________________________________

Doc No. FM5590 issue C Page 2
CONTENTS
Section
Topic
Page
1
Product Overview
2
2
Safety Instructions
2
3
Call Logger Kit Options
3
4
Touchsafe Pro Panel Setup
4
5
Hardware Requirements
4
6
Installing the PC Software
4
7
First Application Run
5
8
Creating Site Details
6
9
View Site Details
7
10
Email Alerts Setup
8
11
InTouch Push Notifications Setup
9
CONTENTS
1. PRODUCT OVERVIEW
The Touchsafe Pro Call Logger software allows the entire call history to be downloaded from the Nursecall
system for detailed analysis of all events including call types and response times etc.
Custom reports can be created by setting filters and changing date ranges, results can be displayed, printed
and exported as PDF files in a variety of different graphical and list formats.
The Push Notification feature allows system events to be sent to a mobile device. Note: the mobile device
requires the Aidcall InTouch app installed and the Touchsafe Pro Panel software must be version V4.00a
onwards.
The Call Logger software allows multi-site management from a single PC Workstation.
ENTS
2. SAFETY INSTRUCTIONS
Read and understand these instructions before use and keep for future reference.
Do not disassemble, cut-down or extend the interface cable.
The PC will require Windows XP, Vista, Windows 7, 8 or 10.
The PC will require a USB Port.
The PC will require an Ethernet Port.
This software is only compatible with the Aidcall Touchsafe Pro Nursecall system.
S

Doc No. FM5590 issue C Page 3
3. CALL LOGGER KIT OPTIONS
There are 2 different Touchsafe Pro Call Logger kits; the same software is included in each kit, it’s only the
type of interface cable that differs.
Description
Part No.
Touchsafe Pro Call Logger Software inc Crossover Lead
E50520
Touchsafe Pro Call Logger Software inc Patch Lead
E50525
E50520 KIT
This kit includes a 3 metre Cat5e Crossover Patch Lead for direct connection between the Touchsafe Pro
Master Panel (ID 1) and a PC Workstation running the Call Logger software.
E50525 KIT
This kit includes a 3 metre Cat5e Patch Lead for connecting the Touchsafe Pro Master Panel (ID 1) to a PC
Workstation running the Call Logger software via a Local Area Network (LAN).
Touchsafe Pro
Master Panel
PC Workstation
Touchsafe Pro
Master Panel
PC Workstation
Printer
Server
PC Workstation
PC Workstation
Hub or Switch

Doc No. FM5590 issue C Page 4
4. TOUCHSAFE PRO PANEL SETUP
On the Touchsafe Pro Master Panel (ID1) Log in as an Engineer and select the Set IP Address option, the
screen will look like this;
5. HARDWARE REQUIREMENTS
Before installing the Call Logger software please check your PC has the following;
•Windows XP, Vista, Windows 7, 8 or 10.
•USB 2.0 Port
•Ethernet Port
•256MB Free Memory
6. INSTALLING THE PC SOFTWARE
The Call Logger software is supplied on a USB flash drive.
Insert the flash drive into a USB Port on your PC.
Double-click on Setup.exe and follow the on-screen instructions.
An icon will be created on your Desktop.
Setup.exe will automatically install .NET Framework 4.0 if it is not already installed on your PC.
Call Logger software will be installed in C:\Program Files (x86)\Aidcall\TouchsafePro Call Logger.
TS
An IP address must be setup when a PC
running the Call Logger software is connected
to the Ethernet Port of the Touchsafe Pro
Panel.
If Use DHCP is un-checked, an IP Address,
Subnet Mask and Gateway can be entered
into the relevant fields. This information can
be obtained from the PC being connected
directly to the Panel or from your IT
Administrator.
Press the Set IP button to save the settings.
Enter the Push Notification IP into the
relevant field and Tick the Enable Push
Notification check box.
Press the Save button to save the settings.
Press the Close button to exit.

Doc No. FM5590 issue C Page 5
7. FIRST APPLICATION RUN
On the first run of the application you will have to
Log in with the following credentials;
User Name: admin
Password: admin@1
Click-on Log in and the main screen should
open as shown below;
Click-on the Settings tile (Gear Wheel)
to open the User Settings page.
On the User Settings page enter details for the
new user making sure to allocate Administrator
privileges.
Note: the email details are for Alerts only –see
section 10. This email is the Account that emails
are sent from –you may need to contact your IT
Administrator to obtain this information.
If Alerts are not required then these fields can be
left blank.
Click-on Write to save the new user details.
Close the User Settings page.
On the main page click-on the tile to Log-out.

Doc No. FM5590 issue C Page 6
8. CREATING SITE DETAILS
Log in using the credentials created in the
previous step and open the Site Settings page.
On the Site Settings page fill out the boxes with
the relevant site details.
Enter the Site IP Address to match the
Touchsafe Pro panel.
The Site Port Number is always 8080.
Click-on Write to save the new site details.
Repeat as above to create multiple sites as
required.
Allocate the site(s) to the user by selecting the
user from the “Select User”drop down,
checking the site name(s) and clicking the
Update button.
Close the Site Settings page.

Doc No. FM5590 issue C Page 7
9. VIEW SITE DETAILS
Refer to the Touchsafe Pro Call Logger User Guide (Aidcall Doc No. FM5595) for details on how to
download data from the Nursecall system and create reports.
On the main screen click-on the Refresh tile
(2 Blue Arrows) and the site details will
appear.
Note: a Refresh also polls all sites for data
Multiple Sites
Where the Call Logger is set up for multiple
sites these appear on the main screen and
can be scrolled across using the left and
right scroll buttons.

Doc No. FM5590 issue C Page 8
10. EMAIL ALERTS SETUP
From the main screen click-on the Settings tile
(Gear Wheel) to open the User Settings page.
On the User Settings page enter the new user
and email details for the Account that emails are
sent from. You may need to contact your IT
Administrator to obtain this information.
Click-on Write to save the new user details.
Click-on Open Alerts Settings Page button and
refer to the Call Logger User Guide (Aidcall Doc
No. FM5595) for details on how to create Rules
and Alerts.

Doc No. FM5590 issue C Page 9
11. INTOUCH PUSH NOTIFICATIONS SETUP
The V4.00 Call Logger acts as a Push Server to generate Push Notifications to the Aidcall InTouch app.
The PC running the Call Logger software will require internet access.
Push Server Setup
Navigate to the ‘Push Notifications’ form, this can be accessed from the ‘Settings’ form of the Call Logger.
Go to the Push Server Tab as shown below.
1) If creating a new Push Server highlight the Create New radio button. Note: Only one Push Server
can be setup per Call Logger installation. If modifying or deleting Push Server details highlight the
Modify/Delete radio button.
2) Give the Push Server a name.
3) Enter the IP address of the network adaptor connecting to the Touchsafe Pro panel. This is the IP
address of the network adaptor on the PC running the Call Logger.
4) Enter the Push Server address in the ‘Set IP Address’ programming page of the Touchsafe Pro
Display Panel.
5) Enter the Push Server Port as 8765.
6) If creating a new Push Server click the Write button, if modifying or deleting click the relevant
button.

Doc No. FM5590 issue C Page 10
11. INTOUCH PUSH NOTIFICATIONS SETUP
Push User Setup
Go the Push User Details tab as shown below.
1) If creating a new Push User highlight the Create New radio button. If modifying or deleting Push
Server details highlight the Modify/Delete radio button.
2) Enter a unique Push User Name.
3) Enter a Push User Token. The Push User token can be obtained from the Aidcall InTouch app and is
a seven character string.
4) Select which telecare push notifications the user will receive. Either alarm events, low battery
events or both. This filter is for all telecare devices.
5) If creating a new Push User click the Write button, if modifying or deleting click the relevant button.
Otros manuales para Touchsafe Pro
7
Tabla de contenidos
Otros manuales de Terminal táctil de Aidcall