Agilent Technologies U2121A Manual de usuario

Agilent Technologies
Agilent U2100A Series
Digital IO, 32-Terminal
Quick Start Guide

2 Agilent U2100A Series Digital IO, 32-Terminal Quick Start Guide
Safety Information
The following general safety precautions must be observed during all phases of operation of this instrument. Failure
to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of
design, manufacture, and intended use of the instrument. Agilent Technologies, Inc. assumes no liability for the cus-
tomer’s failure to comply with these requirements.
This data acquisition device is designed for use according to Pollution Degree 2 and safety-certified in compliance
with:
•IEC 61010-1:2001/EN 61010-1:2001
•USA: UL61010-1: 2004
•Canada: CSA C22.2 No. 61010-1:2004
WARNING
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like
that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed
beyond a WARNING notice until the indicated conditions are fully understood and met.
CAUTION
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly
performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAU-
TION notice until the indicated conditions are fully understood and met.
• Do not load the output terminals above the specified current limits.
• Do not use the device if it appears damaged or defective.
• Observe all markings on the device before connecting any wiring to the device.
• Turn off the device and application system power before connecting any wiring to the IO terminals.
• Do no operate the device in the presence of flammable gases or fumes.
• Do no install substitute parts or perform any unauthorized modification to the device.
• Do not operate the device with the removable cover detached or loosened.
• Before removing the device cover, always disconnect the power cable and any external circuit.
CAUTION
• Applying excessive voltage or overloading the device will cause irreversible damage to the circuitry.
• Use the device with the cables provided.
• Always connect to a USB device that will limit the output current to the maximum rated current of this equipment.
WARNING

Agilent U2100A Series Digital IO, 32-Terminal Quick Start Guide 3
Safety Symbol
The Instruction Documentation Symbol. The product is marked with this
symbol when it is necessary for the user to refer to the instructions in the
supplied documentation.
Regulatory Markings
The CE mark shows that the product complies with all the relevant Euro-
pean Legal Directives.
ICES/NMB-001 indicates that this ISM device complies with Canadian
ICES-001.
The CSA mark is a registered trademark of the Canadian Standards Associ-
ation. A CSA mark with the indicators “C” and “US” means that the prod-
uct is certified for both the U.S. and Canadian markets, to the applicable
American and Canadian standards.
The UL Mark is a registered trademark of Underwriters Laboratories Inc.
UL listing mark with the indicators "C" and "US indicates the product com-
pliance with both Canadian and U.S. requirements.
The C-tick mark is a registered trademark of the Spectrum Management
Agency of Australia. This signifies compliance with the Australian EMC
Frame work regulations under the terms of the Radio Communications Act
of 1992.
This product complies with the WEEE Directive (2002/96/EC) marking
requirement. The affixed product label indicates that you must not discard
this electrical/electronic product in domestic household waste.
Additional Safety Information
For further information, refer to “Safety Notices” section in the Agilent U2100A Series Digital IO,
32-Terminal User’s Guide.

4 Agilent U2100A Series Digital IO, 32-Terminal Quick Start Guide

Agilent U2100A Series Digital IO, 32-Terminal Quick Start Guide 5
Contents
Introduction to the Agilent U2100A Series Data Acquisition Devices 6
Standard Purchase Items Checklist 6
Product Outlook 7
General Specifications 9
Introduction to the Agilent U2121 Software 10
A. Check Your System Requirements 12
B. Check Your Pre-Installed IO Libraries Suite 13
C. Install the Agilent IO Libraries Suite Version 14.2 or Higher 14
D. Installing Agilent U2121 Software 15
i. Agilent U2121 IVI Driver 15
ii. Agilent DIO Diagnostics Application 17
E. Connecting the U2100A Series DAQ 19
F. Launch Your Agilent DIO Diagnostics 20
The Agilent DIO Diagnostics Basic Operations 22
Feature Tab Options 22
Menu Bar Options 23
Toolbar Option 25
Edge Detection Event Log 26
Additional Information 27
Your Other References ... 27

6 Agilent U2100A Series Digital IO, 32-Terminal Quick Start Guide
Introduction to the Agilent U2100A Series Data Acquisition
Devices
Agilent U2100A Series data acquisition (DAQ) is a portable USB Digital
IO that is affordable and delivers reliable data acquisition solution for
digital signals. It is ideal for a broad variety of applications in both
industrial and scientific environments. There are 3 models featuredin the
Agilent U2100A Series DAQ: U2121A, U2122A and U2123A.
This quick start guide includes information of the Agilent U2100A series
data acquisition (DAQ)’s product specifications and overview. This guide
also covers the software and hardware driver installation guidelines, and
how to get started with the Agilent U2121 Software.
Standard Purchase Items Checklist
Inspect and verify the following items for the standard purchase of
U2100A Series. If there are missing items, contact the nearest Agilent
Technologies Sales Office.
✔U2121A/U2122A/U2123A USB Digital IO Module
✔USB Interface Cable
✔Terminal Block (4 pcs)
✔DIN Rail Clamp (2 pcs)
✔Agilent U2100A Series Digital IO, 32- Terminal Quick Start Guide
✔Agilent USB Digital IO, 32- Terminal U2100A Series Product Reference
CD- ROM
✔Agilent Automation- Ready CD (contains the Agilent IO Libraries
Suite)

Agilent U2100A Series Digital IO, 32-Terminal Quick Start Guide 7
Product Outlook
Top View
Front View
Terminal Block
Plastic Casing
Name Plate
Pin Number
Terminal Block
USB Power Indicator
USB Interface
Connector

8 Agilent U2100A Series Digital IO, 32-Terminal Quick Start Guide
Side View
Back View
Bottom View
Plastic Casing
Terminal Block
Terminal Block
Markings
Removable Cover
Pin Assignment Diagram
Model & Serial
Grommet
DIN Rail Clamp Slot
Number Label

Agilent U2100A Series Digital IO, 32-Terminal Quick Start Guide 9
General Specifications
OPERATING ENVIRONMENT
•Full accuracy at 0 °C to 55 °C
•Full accuracy up to 90 % RH at 40 °C (Non-condensing)
•Altitude up to 3000 m
STORAGE COMPLIANCE
•–40 °C to 70 °C
SAFETY COMPLIANCE
Certified by:
•IEC 61010-1:2001 / EN 61010-1:2001 (2nd Edition)
•USA: UL61010-1: 2004
•Canada: CSA C22.2 No.61010-1:2004
ENVIRONMENTAL CONTROL
•Pollution Degree 2
EMC COMPLIANCE
•Certified to IEC/EN 61326: 1998 / CISPR 11, Group 1, Class A
SHOCK & VIBRATION
•Tested to IEC / EN 60086-2
PHYSICAL CHARACTERISTICS
•I/O connectors: USB series B receptacle, 10 position terminal block
(4 pieces)
•Terminal block I/O wiring: AWG 18 to 26 conductor wires with
insulation stripped from the end by 7 mm. Use suitable ferrule for
multistranded wires (do not solder).
•Terminal block screw torque: 2 kg-cm
DIMENSION (HxWxD)
•154.60 mm x 120.00 mm x 32.60 mm
WEIGHT
•270 g / 0.595 lbs
WARRANTY
•3 years

10 Agilent U2100A Series Digital IO, 32-Terminal Quick Start Guide
Introduction to the Agilent U2121 Software
The Agilent DIO Diagnostics is a software utility that helps you to quickly
connect and configure your Agilent U2100A Series DAQ, verify operation,
and troubleshoot connectivity problems.
You can use Agilent DIO Diagnostics to:
•Discover, identify, and verify communication with the U2100A Series
DAQ connected to your PC or to your local area network.
•Communicate interactively with the U2100A Series DAQ.
•Set up non- volatile settings for the U2100A Series DAQ.
The Agilent U2121 Software Start-Up
If you are using the U2100A Series DAQ with the Agilent U2121 Software,
follow the step- by- step instructions as shown in the following flowchart.
NOTE
•If you do not wish to specifically use the U2100A Series DAQ with the Agilent U2121
software, and use the DAQ devices with Agilent VEE, LabVIEW or Microsoft Visual Studio
only, you can skip steps D(ii) and F in the following flowchart.
•You need to install IVI-COM driver before using the U2100A Series DAQ with Agilent VEE,
LabVIEW or Microsoft Visual Studio.
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Idiomas:
Otros manuales de Sistema de E/S de Agilent Technologies
Manuales populares de Sistema de E/S de otras marcas

WAGO
WAGO 750-344 Manual de usuario

Teknim
Teknim TWM-1887 Manual de instrucciones

Intelligent Appliance
Intelligent Appliance IA-2662-E Manual de usuario

BERGHOF
BERGHOF ECC DIO 16/16 Manual de instrucciones

Advantech
Advantech PCM-27J3AU Manual de instalación y operación

Festo
Festo CP-E08-M12-CL Manual de usuario