Ag Leader Technology Raven Accu-Flow ISO Kit Manual de usuario

DirectCommand
Installation
Raven Accu-Flow ISO Kit
Ag Leader Technology
PN: 2006375 Rev. B February 2015 Page 1 of 15
Note: Indented items indicate parts included in an
assembly listed above
Part Name/Description
Part Number
Quantity
Raven Accu-Flow ISO Kit 4200140 1
GEN 2 Large Module Mounting Kit 2001370 1
Deutsch Dust Plug – 12 Pin 2002899-12N 1
Installation Instructions – Raven Accu-Flow Kit 2006375 1
Implement Switch 4001507 1
Accu-Flow Control Valve Adapter (Optional) 4001635 1
Cable – ISOBUS Breakout – Type 1 4002597-008 1
CAN Implement Switch Cable 4002658 1
Liquid Rate Control Module 4002861 1
Local CAN Terminating Plug 4002870 1
Local CAN Terminating Receptacle 4002871 1
CAN Implement Switch Module 4002911 1
Cable – Active Termination (Imp) 4003122 1
Flow Control Channel Cable 4003970-6 1
Cable – ISOBUS Implement 4004110-12 1
Part Name/Description
Part Number
Quantity
ISO Swath Control Kit 4200142 1
Cable – Local CAN Breakout – Type 1 4002567-008 1
Liquid Swath Control Module 4002862 1
12 Section Boom Cable 4003949-6 1

Ag Leader Technology DirectCommand Installation
Raven Accu-Flow ISO Kit
Page 2 of 15 February 2015 PN: 2006375 Rev. B
Important
Notices You will save time and prevent wrong installation of components
by closely following these step-by-step instructions. If you have
questions, call Ag Leader Technology at 515-232-5363 ext. 1.
Direction words (LEFT and RIGHT) are commonly used when
describing an installation procedure. Interpret direction words as if
standing behind equipment and looking forward.
Signal words (CAUTION, IMPORTANT and NOTE) are provided
to draw attention to information that is important for the
safe/correct installation and operation of this product.
CAUTION – will alert you to situations that will impact the
physical safety of you or others.
IMPORTANT – will alert you to the potential for damage to
the product or loss of data.
NOTE – will provide you with additional information to
simplify a procedure or clarify a process.
Read all instructions first to familiarize yourself with the
installation procedures.
Keep parts list and installation instructions for use as a
reference after completing installation.
Section
Contents Item Page
Common Components 3
Component and Cable Layout 4
Safety Notices 5
Installing Liquid Product Control System 6
Installing the Accu-Flow Cabling 8
Installing the ISO Swath Control Kit (Optional) 10
Installing the Implement Switch (Optional) 12
Setting Up the Display 14

DirectCommand
Installation
Raven Accu-Flow ISO Kit
Ag Leader Technology
PN: 2006375 Rev. B February 2015 Page 3 of 15
Common
Components This section contains illustrations of components common to all
DirectCommand installations. Their purpose is to ensure proper
identification and installation in the sections that follow.
ISO Liquid Module ISO Swath Module

Ag Leader Technology DirectCommand Installation
Raven Accu-Flow ISO Kit
Page 4 of 15 February 2015 PN: 2006375 Rev. B
Component
and Cable
Layout

DirectCommand
Installation
Raven Accu-Flow ISO Kit
Ag Leader Technology
PN: 2006375 Rev. B February 2015 Page 5 of 15
Safety
Notices
CAUTION: Implement should be lowered to ground or on
mechanical safety stops before starting work. Do not work on
implement supported by hydraulic system only.
CAUTION: Be sure to wear proper eye protection when using any
power tools, such as when drilling any mounting holes.
IMPORTANT: Check behind vehicle and implement panels for any
hoses, wiring, controls, etc. that could be damaged when drilling
any mounting holes.
IMPORTANT: Disconnect Ag Leader Display, DirectCommand
components and flow meter from electrical system when welding
on equipment or jump starting unit to prevent component damage
due to power surges or excessive current
IMPORTANT: If using a non Ag Leader GPS receiver, make sure
to install the Null Modem Cable included in the Display kit, to
prevent damage to the Display or the GPS receiver.
IMPORTANT: Use the Dielectric grease to coat the seals and
terminals of each connector that will be exposed to weather or
chemicals as you plug them in.
NOTE: Be sure to follow the alignment keys on the plugs and the
receptacles carefully. Do not use excessive force when mating
connectors.
IMPORTANT: Do not drill holes in tool bar mainframe. Due to high
stress loads on toolbar, cracking may occur from drilled holes.

Ag Leader Technology DirectCommand Installation
Raven Accu-Flow ISO Kit
Page 6 of 15 February 2015 PN: 2006375 Rev. B
Installing
the Liquid
Product
Control
System
Parts required for procedure:
From DirectCommand Kit:
(1) Large Module Mounting Kit PN: 2001370
(1) ISOBUS Breakout Cable PN: 4002597-008
(1) Liquid Rate Control Module PN: 4002861
(1) Local CAN Terminating Plug PN: 4002870
(1) Local CAN Terminating Rec. PN: 4002871
(1) ISOBUS Active Term. Cable PN: 4003122
(1) ISOBUS Implement Cable PN: 4004110-12
Step-by-Step for
Installing the
Liquid Product
Control System
1. Determine a mounting location for the Liquid Rate Control
Module PN: 4002861. Make sure to choose a mounting location
that is big enough for Liquid Swath Control Module PN: 4002862
if it is needed. Mount modules where they will be protected from
impact and other hazards.
2. Use the 5 inch carriage bolts and 5/16 hardware from the Large
Module Mounting Kit PN: 2001370 to mount the modules to the
Module Mounting Plate.
3. Use the 7 inch carriage bolts, 5/16 hardware, and Large Module
Bracket Strap from the Large Module Mounting Kit to mount the
Module Mounting Plate to the machine.
Rate and Swath Control Modules Mounted to Plate
4. The cables leading from the Liquid Product Control Module to the
Accu-Flow controls and the cooler are six feet in length, so mount
Liquid Product Control Module where cables will reach.

DirectCommand
Installation
Raven Accu-Flow ISO Kit
Ag Leader Technology
PN: 2006375 Rev. B February 2015 Page 7 of 15
5. Plug the 24-pin FCI connector of the ISOBUS Breakout Cable,
PN: 4002597-008 to the mating connector of the Liquid Rate
Control Module.
6. Connect the 6-pin Metripack plug of the ISOBUS Implement
Cable PN: 4004110-12 to the 6-pin Metripack receptacle of the
ISOBUS Breakout Cable.
7. Connect the 6-pin Metripack plug of the ISOBUS Breakout
Cable to the 6-pin Metripack receptacle of the Active Terminator
Cable (Imp), PN: 4003122.
8. Connect the Local CAN Terminating Receptacle, PN: 4002871
and the Local CAN Terminating Plug, PN: 4002870 to the
mating connectors of the ISOBUS Breakout Cable.
Liquid Rate Control Module with ISOBUS Cabling
9. Route the round metal connector end of the ISOBUS Implement
Cable towards the tractor.
10.Route cable to avoid any sharp edges and pinch points. Bundle
up all excess cable and tie with zip-ties.
Local CAN
Terminatin
g
Rec.
Local CAN
Terminating Plug
ISOBUS
Breakout Cable ISOBUS
Im
p
lement Cable
Active Terminator
Cable

Ag Leader Technology DirectCommand Installation
Raven Accu-Flow ISO Kit
Page 8 of 15 February 2015 PN: 2006375 Rev. B
Installing
the Accu-
Flow
Cabling
Parts required for procedure:
From DirectCommand Kit:
(1) Flow Control Channel Cable PN: 4003970-6
(1) Dust Plug – 12 pin PN: 2002899-12N
Optional Cables From DirectCommand Kit
(1) Accu-Flow Control Valve
Adapter PN: 4001635
(1) Auxiliary Valve Harness See Table A
Table A
Auxiliary Valve Harness Part Number
Weatherpack 3-Pin Shroud 4003980-6
Conxall 4-Pin Connector 4003981-6
DIN B 2-Wire 4003982-6
DIN B 3-Wire 4003983-6
DIN A 2-Wire 4003984-6
DIN A 3-Wire 4003985-6
Step-by-Step for
Installing the
Accu-Flow
Cabling
Note: These instructions are specific to the Accu-Flow Control
Valves with a 4 position ConXall Connection. If this
DirectCommand system is installed using a control valve that
does not have 4 position ConXall Connector, go to step 11.
1. Connect the gray 24-pin FCI plug of the Flow Control Channel
Cable PN: 4003970-6 to the Liquid Rate Control Module.
2. The black round 3-pin plug of the Flow Control Channel Cable
connects to the mating receptacle on the flow meter. Twist the
connector to lock and seal the connection.
3. The black round 4-position plug of the Flow Control Channel
Cable connects to the mating receptacle on the control valve.
Twist the connector to lock and seal the connection.
4. Use the Dust Plug PN: 2002899-12N to seal the brown
receptacle on the Liquid Rate Control Module.
5. Connect the gray 2-pin receptacle of the Flow Control Channel
Cable to one of the gray 2-pin plugs of the ISOBUS Implement
Cable.

DirectCommand
Installation
Raven Accu-Flow ISO Kit
Ag Leader Technology
PN: 2006375 Rev. B February 2015 Page 9 of 15
6. Connect the 2-pin plug of the Flow Control Channel Cable to the
mating receptacle on the Liquid Rate Control Module.
Note: Steps 7-10 are for toolbars that utilize a Main On/Off Valve
and Auxiliary Valve.
7. Connect the 4-pin Deutsch receptacle of the Auxiliary Valve
Harness, from Table A above, to the mating plug on the Flow
Control Channel Cable.
8. Tee the gray 2-pin connectors of the Auxiliary Valve Harness into
the gray 2-pin connectors of the Flow Control Channel Cable.
Flow Control Channel Cable and Auxiliary Valve Harness
9. Plug the connector labeled “Aux Valve 1” into the Main On/Off
Valve.
10. Plug the connector labeled “Aux Valve 2” into the Auxiliary Valve
if the system is equipped with one.
Flow Control
Channel Cable
Auxiliary Valve
Harness

Ag Leader Technology DirectCommand Installation
Raven Accu-Flow ISO Kit
Page 10 of 15 February 2015 PN: 2006375 Rev. B
IMPORTANT: Prior to the use of any anhydrous toolbar with multiple
section shutoffs, consult the anhydrous cooler, plumbing
components, and manifold manufacturers to ensure that the
components have been properly selected and installed. These
manufacturer's instructions must be followed to ensure even product
distribution across the width of the toolbar. Ag Leader Technology is
not responsible for application errors resulting from improper
component design, selection, or assembly.
Note: Steps 11-13 are for systems with Control Valves that do not
have a 4 position ConXall Connector only.
11. Connect the 4 position ConXall connector of the Control Valve
Adapter Cable PN: 4001635 to the mating connector of the Flow
Control Channel Cable PN: 4003970-6.
12. Connect the 2 position molded connector of the adapter cable to
the Accu-Flow Control Valve
13. Connect the spade terminal with the black wire to the white wire
coming from the Accu-Flow Valve. Connect the spade terminal
with the red wire to the red wire coming from the Accu-Flow
Valve. Go back to step 1.
14. Route all cables to avoid any sharp edges and pinch points.
Bundle up all excess cable and tie with zip-ties.
Installing
the ISO
Swath
Control Kit
(Optional)
Parts required for procedure:
(1) Local CAN Breakout Cable PN: 4002567-008
(1) Liquid Swath Control Module PN: 4002862
(1) 12 Section Boom Cable PN: 4003949-6
Step-by-Step for
Installing the
ISO Swath
Control Kit
(Optional)
1. Mount the Liquid Swath Control Module PN: 4002862 to the
Module Mounting Plate with the Liquid Rate Control Module.
2. Plug the 24-pin FCI connector of the Local CAN Breakout Cable,
PN: 4002567-008 to the mating connector of the Liquid Swath
Control Module.
3. Connect the Local CAN Terminating Receptacle, PN: 4002871
to the mating plug of the Local CAN Breakout Cable.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario











