AFi N-111 Manual de usuario

1
Net I/O N-111 User’s Manual
Revision 8/2/2013

2
WARRANTY INFORMATION
American Fibertek, Inc warrants that at the time of delivery the products delivered will be
free of defects in materials and workmanship. Defective products will be repaired or
replaced at the exclusive option of American Fibertek. A Return Material Authorization
(RMA) number is required to send the products back in case of return. All returns must
be shipped prepaid. This warranty is void if the products have been tampered with. This
warranty shall be construed in accordance with New Jersey law and the courts of New
Jersey shall have exclusive jurisdiction over this contract. EXCEPT FOR THE
FOREGOING WARRANTY, THERE IS NO WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR
OTHERWISE, EXPRESSED OR IMPLIED, WHICH EXTENDS BEYOND THE
WARRANTY SET FORTH IN THIS AGREEMENT. In any event, American
Fibertek will not be responsible or liable for contingent, consequential, or incidental
damages. No agreement or understanding, expressed or implied, except as set forth in this
warranty, will be binding upon American Fibertek unless in writing, signed by a duly
authorized officer of American Fibertek.
© Copyright 2011 American Fibertek, Inc.

3
Table of contents
Introduction................................................................................................................4
Overview
Package Checklist
Product Features
Product Specifications
Getting Started...........................................................................................................7
Panel Layout
Connecting the Hardware
LED indicators
Real-time clock
Initial IP configuration..............................................................................................13
Factory default IP
Reset sequence
NTP/timeserver configuration
Operating modes......................................................................................................17
Overview
Serial Server Mode
Serial Client Mode
Alarm input forwarding
Aux outputs
Pilot interface
Web Interface............................................................................................................22
Connecting to the N-111
Interface layout
Operator setup
Global settings
IP Ethernet Setup
NTP Setup
Alarm Setup
Aux Setup
Communications
Watchdog
Upload Firmware
SNMP
Reboot Net I/O
Pinouts and connectors...........................................................................................36
Power

4
Ethernet
Serial
Aux/Alarm

5
1
Introduction
Overview
Package Checklist
Product Features
Product Specifications

6
Overview
Thank you purchasing your American Fibertek N-111 Net I/O. Please take a few minutes
to read these installation instructions in order to obtain maximum performance from this
product.
The AFI V’NES (Video Network Enterprise Solution) N-111 device allows serial data and
contact closure signals to be made accessible on and linked over a network, with N-111
devices acting as transparent bridges to link together customer equipment. This permits
contact closure signals – such as door opening sensors, alarm buttons, or motion
detectors – to be linked to remote alarm annunciation, or serial data sources such as key
pads or card registers to send data to a remote monitoring system. N-111 devices can
be linked together over a standard Ethernet connection, making it possible to use a pre-
existing LAN or the Internet for device communication.
Package Checklist
Net I/O
Installation guide
Power cord
Product Features
Serial connectivity over network
Auto-detect 10/100 Ethernet connection
1 port RS232, 485 2W (Half Duplex) or 4W (Full Duplex)
Contact output (Form C, 1500KV isolated)
Alarm input (configurable as NO/NC)
Alarm transmission over network with verification and retry
Product Specifications
LAN
Ethernet 10/100 Mbps, RJ45
Protection 1500KV magnetic isolation
Serial
Serial interface RS232/RS485
Duplex Full or half duplex
Number of ports 1
Signals RS2332: TXD/RXD, CTS/RTS
RS485: RX+/-, TX+/-
Baud rate 0 to 57600 bps
Contact closures
Contact type Form C

7
Number of contact outputs 1
Current rating 1A
Voltage rating 42VDC
29VAC RMS
Battery backup
Real-time clock 10 years
User settings Indefinite
Power requirements
Connector type Screw terminal
Power input voltage 12 VDC
Power required 5W maximum
POE class Class 0
POE type 802.3af
Mechanical
Dimensions 4.43” x 4.175” x 1.125”
113mm x 106mm x 29mm
Weight 8 oz (0.226kg)
Mounting Surface mount
Environmental
Storage temperature -20C to +85C (-4F to 185F)
Operating temperature 0C to 70C (32F to 158F)
Operating humidity range 10 - 95%RH

8
2
Getting Started
Panel Layout
Connecting the Hardware
LED indicators
Real-time clock

9
Panel Layout
N-111 Front
N-111 Rear
Connecting the Hardware
Connecting power
The N-111 has a two position screw terminal which accepts input from an external
12VDC power supply. To connect an external power supply, use two wires, 16-28 AWG
in size. Strip about ¼” of the insulation from the end of the wires before inserting them
into the terminal block. Tighten the terminal screws to secure the wires in the terminal
block. Be sure that the polarity of the applied power is as indicated. Connecting power
with incorrect polarity may damage the N-111.
The N-111 is also capable of being powered over the network connection through
802.3af Power over Ethernet (PoE). To power a N-111 over POE connect one end of an
Ethernet cable to the N-111’s Ethernet port and the other end to a PSE network switch,
midspan injector, or similar device capable of providing power over an Ethernet
connection in accordance with the 802.3af POE standard. When used in this
configuration the DC power input terminal block should not be connected to a power
supply.
Connecting to the network
Connect one end of an Ethernet cable to the N-111’s Ethernet port and the other end of
a cable to the Ethernet network.

10
Connecting a serial device
The N-111 has a DB-9 serial port which can be configured in software for several
different communications modes. The method used to connect to the serial port will
vary depending on the hardware mode selected.
Connecting RS232
To connect the N-111 to a RS232 serial device, connect a serial cable from the serial
port on the rear of the N-111 to the serial device. The N-111 RS232 is configured as a
DTE device.
Connecting RS485 four-wire
To connect to a serial port in RS485 4-wire mode, you will need a DB9 connector wired
as indicated. Four connections will need to be made for the two data transmit lines and
the two data receive lines. Do not make any other connections to any other pins on the
DB9 connector.
Connecting RS485 two-wire
To connect to a serial port in RS485 4-wire mode, you will need a DB9 connector wired
as indicated. Two pairs of pins on the DB9 will need to be bridged together. Two
connections will then need to be made to the bridged pins for the two bidirectional data
lines. Do not make any other connections to any other pins on the DB9 connector.