4
as advised by a company supervisor. This device is not intended for use by persons
with reduced physical, sensory or reasoning capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning use
of the device by a person responsible for their safety.
f. Disconnect battery when not in use for extended periods and before maintenance or
servicing. If the device is not working as it should, has received a sharp blow, has
been dropped, damaged, left outdoors, or dropped into water, do not use and contact
a company supervisor. When service or repair is required, a company supervisor
should contact the Aero HygenX Helpline (1-800-260-0787).
IMPORTANT SAFETY FEATURES
Aero HygenX RAY – Autonomous UVC Robot is equipped with LIDAR, SONAR and onboard
cameras which are used for guidance and to detect objects, motion of persons or other obstructions
which will impede its movement.
The following list outlines the important safety features of Aero HygenX RAY – Autonomous UVC
Robot and the corresponding response of the unit when operating in the autonomous mode.
Auto-Delay during Start-Up: To prevent exposure to UVC light during operation, Aero
HygenX RAY – Autonomous UVC Robot is equipped with a configurable time delay between
directional input on the device, until lamp illumination. This auto-delay allows time for the
operator to exit the aircraft and close the aircraft door before the lamps commence warm-
up. The default value for the auto-delay is 30 seconds. The auto-delay can be set to any
desired time interval (in seconds) between directional input and lamp illumination.
Object and Motion detection within 0.5 metres (1.64 feet): If an object or any motion is
detected within 0.5 metres of the device, Aero HygenX RAY – Autonomous UVC Robot will
stop and the UVC lamps will extinguish. Operator input is required before RAY will re-start.
Human Face detection up to 3 metres (9.84 feet): If a human face is detected within 3.0
metres of the device, Aero HygenX RAY – Autonomous UVC Robot will stop and the UVC
lamps will extinguish. Operator input is required before Aero HygenX RAY – Autonomous
UVC Robot will re-start.
Speed limitation 0.2 metres/second (0.66 feet/second): This is the maximum speed of the
device. For most sanitizing procedures, Aero HygenX RAY – Autonomous UVC Robot will
operate at speeds between 0.1m - 0.15m/second (0.33-0.49 feet/second).
Auto-shutoff if no motion detected: If Aero HygenX RAY – Autonomous UVC Robot
determines it is not safe to proceed (i.e., becomes impeded by an aircraft seat or object on
the floor), it will shut off following no motion detected for more than 20 seconds.