AEMC L605 Manual de usuario

SIMPLE LOGGER®
TEMPERATURE MODULE
L605
ENGLISH User Manual

Owner’s Record
The serial number for the Models L605 is located on the side of the case.
Please record this number and purchase date for your records.
SIMPLE LOGGER®MODEL L605
CATALOG #: 2114.17
SERIAL #: _______________________________________________
PURCHASE DATE: ________________________________________
DISTRIBUTOR: ___________________________________________

Table of Contents
1. INTRODUCTION............................................................................... 2
1.1 International Electrical Symbols................................................2
1.2 DenitionofMeasurementCategories .....................................3
1.3 ReceivingYourShipment..........................................................3
1.4 OrderingInformation.................................................................3
1.4.1 Accessories and Replacement Parts............................3
2. PRODUCT FEATURES ...................................................................... 4
2.1 Indicators and Buttons ..............................................................4
2.2 Inputs and Outputs ...................................................................5
2.3 Mounting ...................................................................................5
3. SPECIFICATIONS............................................................................. 6
3.1 ElectricalSpecications ............................................................6
3.2 MechanicalSpecications ........................................................7
3.3 EnvironmentalSpecications....................................................7
3.4 SafetySpecications ................................................................7
4. OPERATION .................................................................................... 8
4.1 Software Installation .................................................................8
4.2 RecordingData.........................................................................9
4.3 UsingtheSoftware .................................................................10
4.3.1 TheFunctionCommand .............................................10
5. MAINTENANCE ............................................................................. 11
5.1 Battery Installation ..................................................................11
5.2 Cleaning.................................................................................. 11
APPENDIX A ....................................................................................... 12
Importing.TXTFilesintoaSpreadsheet.........................................12
OpeningaSimpleLogger.TXTleinExcel ...........................12
FormattingtheDateandTime ................................................13
RepairandCalibration...........................................................................15
Technical and Sales Assistance ............................................................15
Limited Warranty ...................................................................................16
Warranty Repairs...................................................................................16

2
Simple Logger® Temperature Module Model L605
CHAPTER 1
INTRODUCTION
WARNING
Thesesafetywarningsareprovidedtoensurethesafetyofper-
sonnel and proper operation of the instrument.
• Read the instruction manual completely and follow all safety
informationbeforeoperatingthisinstrument.
• Usecautiononanycircuit:Potentiallyhighvoltagesandcur-
rents may be present and may pose a shock hazard.
• Read the Safety Specications section prior to using the
instrument. Never exceed the maximum voltage ratings
given.
• Safety is the responsibility of the operator.
• Formaintenance,useonlyoriginalreplacementparts.
• NEVER open the back of the instrument while connected to
any circuit or input.
• ALWAYS inspect the instrument and lead prior to use.
Replace any defective parts immediately.
• NEVER use the Model L605 on electrical conductors rated
above30VinovervoltagecategoryIII(CATIII).
1.1 International Electrical Symbols
Thissymbolsigniesthattheinstrumentisprotectedbydoubleor
reinforcedinsulation.Useonlyspeciedreplacementpartswhen
servicingtheinstrument.
This symbol on the instrument indicates a WARNING and that
the operator must refer to the user manual for instructions before
operating the instrument. In this manual, the symbol preceding
instructions indicates that if the instructions are not followed, bodily
injury,installation/sampleandproductdamagemayresult.
Riskofelectric shock.Thevoltage at thepartsmarked with this
symbolmaybedangerous.

Simple Logger® Temperature Module Model L605
3
1.2 Definition of Measurement Categories
Cat. IV: For measurements performed at the primary electrical supply
(<1000V) such as on primary overcurrent protection devices,
ripple control units, or meters.
Cat. II: For measurements performed on circuits directly connected to
the electrical distribution system. Examples are measurements
on household appliances or portable tools.
Cat. III:For measurements performed in the building installation at
the distribution level such as on hardwired equipment in xed
installation and circuit breakers.
1.3 Receiving Your Shipment
Uponreceivingyourshipment,makesurethatthecontentsareconsistent
withthepackinglist.Notifyyourdistributorofanymissingitems.Iftheequip-
mentappearstobedamaged,leaclaimimmediatelywiththecarrierand
notifyyourdistributoratonce,givingadetaileddescriptionofanydamage.
Savethedamagedpackingcontainertosubstantiateyourclaim.
1.4 Ordering Information
Simple Logger®Model L605 ............................................. Cat. #2114.17
(Temperature–Internal/ExternalThermistor)
Includes software (CD-ROM), 6 ft DB-9 RS-232 serial cable, 9V Alkaline battery and user
manual.
1.4.1 Accessories and Replacement Parts
ThermistorProbewithEpoxybead,6ft .............................. Cat. #2114.19
Thermistor Probe with 4" Stainless Steel Sheath, 6 ft......... Cat. #2114.20
Order Accessories and Replacement Parts Directly Online
Check our Storefront at www.aemc.com/store for availability

4
Simple Logger® Temperature Module Model L605
CHAPTER 2
PRODUCT FEATURES
2.1 Indicators and Buttons
TheSimpleLogger®has one button and one indicator. Both are located
on the front panel. The PRESSbuttonisusedtostartandstoprecordings
andtoturntheloggeronandoff.
TheRedLEDindicatesthestatusofthelogger:
• Single Blink: STAND-BYmode
• Double Blink: RECORDmode
•Continuously On: OVERLOAD condition
•No Blinks: OFF mode
1
2
3
4
(1) Start/Stop Button
(2) Inline Connector for External Sensor
(3) LED Indicator
(4) RS-232 Interface
LOGGER OPERATION:
1. Press to Start Logging
(Logging = Two Blinks)
2. Press to Stop Logging
(Stand-By = One Blink)
3. Press & Hold 5 sec. to Shut Off
(Off = No Blinks)
Warning: All Data will be Deleted!
Continuous LED Indicates Overload
!INPUT
(10k @ 25°C)
!RS-232
PRESS
!
®
INSTRUMENTS
SIMPLE LOGGER
®
TEMPERATURE MODULE L605

Simple Logger® Temperature Module Model L605
5
2.2 Inputs and Outputs
The Model L605 has an inline connector on the left side and an internal
thermistor sensor.
Therightsideoftheloggerhasafemale9-pin“D”shellserialconnector
usedfordatatransmissionfromthedataloggertoyourcomputer.
2.3 Mounting
YourSimpleLogger®isequippedwithmountingholesinthebaseplate
tabsformounting.Forlesspermanentmounting,theVelcro®pads(sup-
pliedloose)canbeattachedtotheloggerandthesurfacetowhichitwill
be mounted.

6
Simple Logger® Temperature Module Model L605
CHAPTER 3
SPECIFICATIONS
3.1 Electrical Specifications
Number of Channels: 1
Measurement Range:
-4to158°F,-20to70°C(Internal)
-4to212°F,-20to100°C(External)
Input Connection:
InlineConnector
Input Impedance:
Thermistor type 10kΩ@77°F(25°C)
Resolution: 8 Bit
Change in Temperature vs Range
-9.00
-8.00
-7.00
-6.00
-5.00
-4.00
-3.00
-2.00
-1.00
0.00
1.00
2.00
-25
-15
-5
5
15
25
35
45
55
65
75
85
95
Temperature
Change in Temperature/Range
Series1
Series2
Series3
Series4
Series5
Reference condition: 23°C ± 3K, 20 to 70% RH, Frequency 50/60Hz, No AC external mag-
netic Field, DC magnetic eld ≤ 40A/m, battery voltage 9V ± 10%.
Accuracy: 1% of Readings ± 0.25°C

Simple Logger® Temperature Module Model L605
7
Sample Rate:
4096/hrmax;decreasesby50%eachtimememoryisfull
Data Storage: 8192readings
Data Storage Technique:
TXR™TimeExtensionRecording™
Power:
9V Alkaline NEDA 1604, 6LF22, 6LR61
Battery Life Recording:
Upto1yearofrecording@77°F(25°C)
Output:
RS-232 via DB9 connector, 1200 Bps
3.2 Mechanical Specifications
Size: 2-7/8x2-5/16x1-5/8"(73x59x41mm)
Weight (with battery):5oz(140g)
Mounting: BaseplatemountingholesorVelcro®pads
Case Material: Polystyrene UL V0
3.3 Environmental Specifications
Operating Temperature: -4to158°F(-20to70°C)
Storage Temperature:-4to176°F(-20to80°C)
Relative Humidity: 5to95%non-condensing
Temperature Inuence: 5ctsmax
3.4 Safety Specifications
Working Voltage: EN61010,30V,CatIII
*All specications are subject to change without notice

8
Simple Logger® Temperature Module Model L605
CHAPTER 4
OPERATION
4.1 Software Installation
Minimum Computer Requirements
• Windows®7, 8, 8.1, 10
•Processor-486orhigher
• 8MB of RAM
•8MBofharddiskspaceforapplication,400Kforeachstoredle
•One9-pinserialport;oneparallelportforprintersupport
•CD-ROMdrive
1. InserttheSimpleLogger®CDintoyourCD-ROMdrive.
If auto-run is enabled, the Setup program will start automatically. If
auto-run is not enabled, select Run from the Start menu and type in
D:\SETUP(if yourCD-ROMdrive isdriveD. Ifthisis notthe case,
substitutetheappropriatedriveletter).
2. The Set-up window will appear.
Figure 1
Tabla de contenidos