ADF Web HD67B41-B2 Manual de usuario

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 1 of 26
User Manual
Revision 1.
English
OPC UA Server / KNX - Converter
(Order Code: HD67B41-B2)
for Website information:
http://www.adfweb.com/?Product=HD67B41
for Price information:
http://www.adfweb.com/?Price=HD67B41-B2
Benefits and Main Features:
Triple electrical isolation
Power Supply 18…35V DC and 8…24 V AC
Temperature range: -4 °C/+85°C (-4 °F/+185°F)
For others OPC UA Server devices, see also the following links:
OPC UA Server from/to …
www.adfweb.com?Product=HD67B26 (Serial)
www.adfweb.com?Product=HD67B27 (Mod us Master)
www.adfweb.com?Product=HD67B28 (Mod us Slave)
www.adfweb.com?Product=HD67B29 (Mod us TCP Master)
www.adfweb.com?Product=HD67B3 (Mod us TCP Slave)
www.adfweb.com?Product=HD67B31 (Bacnet Master)
www.adfweb.com?Product=HD67B32 (Bacnet Slave)
www.adfweb.com?Product=HD67B33 (CAN)
www.adfweb.com?Product=HD67B34 (CANopen)
www.adfweb.com?Product=HD67B35 (DeviceNet Master)
www.adfweb.com?Product=HD67B36 (DeviceNet Slave)
www.adfweb.com?Product=HD67B37 (DMX)
www.adfweb.com?Product=HD67B38 (EtherNet/IP Master)
www.adfweb.com?Product=HD67B39 (EtherNet/IP Slave)
www.adfweb.com?Product=HD67B4 (J1939)
www.adfweb.com?Product=HD67B42 (MQTT)
www.adfweb.com?Product=HD67B43 (NMEA0183)
www.adfweb.com?Product=HD67B44 (NMEA2000)
www.adfweb.com?Product=HD67B45 (PROFINET Master)
www.adfweb.com?Product=HD67B46 (PROFINET Slave)
www.adfweb.com?Product=HD67B47 (SNMP Manager)
www.adfweb.com?Product=HD67B48 (SNMP Agent)
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67 3
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
User Manual

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 2 of 26
INDEX:
Page
INDEX 2
UPDATED DOCUMENTATION 2
REVISION LIST 2
WARNING 2
TRADEMARKS 2
SECURITY ALERT 3
EXAMPLE OF CONNECTION 4
CONNECTION SCHEME 5
CHARACTERISTICS 6
CONFIGURATION 6
POWER SUPPLY 7
FUNCTION MODES 8
LEDS 9
KNX 1
ETHERNET 11
USE OF COMPOSITOR SW67B41 12
NEW PROJECT / OPEN PROJECT 13
SOFTWARE OPTIONS 14
SET COMMUNICATION 16
OPC UA ACCESS 18
KNX ACCESS 19
UPDATE DEVICE 21
MECHANICAL DIMENSIONS 23
ORDERING INFORMATIONS 24
ACCESSORIES 24
DISCLAIMER 25
OTHER REGULATIONS AND STANDARDS 25
WARRANTIES AND TECHNICAL SUPPORT 26
RETURN POLICY 26
Pagina 2 di 26
UPDATED DOCUMENTATION:
Dear customer, we thank you for your attention and we remind you that
you need to check that the following document is:
Updated
Related to the product you own
To obtain the most recently updated document, note the “document code”
that appears at the top right-hand corner of each page of this document.
With this “Document Code” go to web page www.adfweb.com/download/
and search for the corresponding code on the page. Click on the proper
“Document Code” and download the updates.
REVISION LIST:
Revision
Date Author
Chapter
Description
1. 13/ 3/2 19 Tf All First release version
WARNING:
ADFweb.com reserves the right to change information in this manual about
our product without warning.
ADFweb.com is not responsible for any error this manual may contain.
TRADEMARKS:
All trademarks mentioned in this document belong to their respective
owners.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 3 of 26
SECURITY ALERT:
G
ENERAL
I
NFORMATION
To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and
safety regulation are required for each individual application. The same applies also when using accessories.
I
NTENDED
U
SE
Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator (i.e.
independent limit switches, mechanical interlocks, etc.).
Q
UALIFIED
P
ERSONNEL
The device can be used only by qualified personnel, strictly in accordance with the specifications.
Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and
who have appropriate qualifications for their job.
R
ESIDUAL
R
ISKS
The device is state-of-the-art and is safe. The instruments can represent a potential hazard if they are inappropriately installed and
operated by untrained personnel. These instructions refer to residual risks with the following symbol:
This symbol indicates that non-observance of the safety instructions is a danger for people that could lead to serious injury or
death and / or the possibility of damage.
CE
CONFORMITY
The declaration is made by our company. You can send an email to [email protected]om or give us a call if you need it.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 4 of 26
EXAMPLE OF CONNECTION:

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 5 of 26
Figure
1
: Connection
scheme
for HD67
B
41
-
B2
CONNECTION SCHEME:

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 6 of 26
CHARACTERISTICS:
The HD67B41-B2 is a OPC UA Server / KNX converter.
It allows the following characteristics:
Up to 15 bytes in reading and 15 bytes in writing;
Two-directional information between KNX and OPC UA;
Mountable on 35mm Rail DIN;
Wide power supply input range: 8…24V AC or 12…35V DC;
Wide temperature range: -4 °C / 85°C [-4 °F / +185°F].
CONFIGURATION:
You need Compositor SW67B41 software on your PC in order to perform the following:
Define the parameter of OPC UA;
Define the parameter of KNX line;
Define the list of OPC UA servers connected to the converter;
Define the list of KNX data points accessible on KNX side;
Update the device.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 7 of 26
POWER SUPPLY:
The devices can be powered between a wide range of tensions. For more details see the two tables below.
VAC
VDC
Vmin Vmax Vmin Vmax
HD67B41-B2 8V 24V 12V 35V
Consumption at 24V DC:
Device W/VA
HD67B41-B2 4
Caution: Not reverse the polarity power
HD67B41 -B2

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 8 of 26
FUNCTION MODES:
The device has got two functions mode depending of the position of the Dip1 of ‘Dip-Switch A’:
The first, with Dip1 in Off position (factory setting), is used for the normal working of the device.
The second, with Dip1 in On position, is used for upload the Project/Firmware.
For the operations to follow for the updating (see ‘UPDATE DEVICE’ section).
According to the functioning mode, the LEDs will have specifics functions (see ‘LEDS’ section).

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 9 of 26
LEDS:
The device has got five LEDs that are used to give information of the functioning status.
The various meanings of the LEDs are described in the table below.
LED Normal Mode Boot Mode
1: Device State (green) Blinks slowly (~1Hz) Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
2: OPC UA comm. (yellow) Flashing: OPC UA response
OFF: No OPC UA response
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
3: KNX comm. (yellow) Flashing: KNX communication
OFF: No KNX communication
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
4: Not used OFF Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
5: Link Ethernet (green) ON: Ethernet cable connected
OFF: Ethernet cable disconnected
ON: Ethernet cable connected
OFF: Ethernet cable disconnected

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
OPC UA
Server
/
KNX
Document code: MN67B41_ENG Revision 1. Page 1 of 26
KNX:
KNX is the standard that allows the automated and decentralized management of the
technologic plans of a big typology of structures: commercial buildings, factories,
houses, public locals, schools and so on.
KNX can be used in all the applications and functions for the building automations:
from lighting to control dampers, to the security, to the heating monitoring, to the
conditioning, to the hydric control and alarms, to energy management and so on.
Characteristics Description TP1-256
Medium Shielded Twisted Pair
Topology Linear, Star, Tree or mixed
Baudrate 96 bps
Device supplying Normal: bus powered devices
Optional: remote powered devices
Device power consumption 3 mA- 12 mA
Power Supply Unit (PSU) DC 3 V
Number of PSU’s per physical
Segment Max. 2
Number of connectable devices
per physical Segment Max. 256
Number of addressable devices
per physical Segment Max. 255
Total cable length per physical
Segment Max. 1 m
Distance between two devices Max. 7 m
(*) Taken from KNX specifications
Tabla de contenidos