ADEMCO RapidDome Manual de operación

RapidDome Dome
Owners Operating & Installation Guide
Document Code number – Draft 7-7-00

Table of Contents
Safety Instructions ii
Setting up the RapidDome Dome 1
Wiring Details 1
Settings on the RapidDome Dome Top Board 3
Address Settings 4
Coax Telemetry 4
LED on the RapidDome Dome Bottom Board 5
Alarm Settings 5
Alarm / Relay Connections 6
Installing the RapidDome Dome 8
Installing the RapidDome Dome 8
Sample Configurations and Notes for Twisted Pair Installations 11
Technical Specification 13

Safety Instructions
WARNING! Read these notes before attempting to operate the
RapidDome Dome
Refer all servicing to qualified personnel.
These products are for internal use only.
These products contain static electricity sensitive devices. Please take appropriate
precautions when handling.
Handle the RapidDome Dome with care, as improper handling may cause irreparable
damage to the precision or sensitive parts within this unit.
Never point the camera directly towards a bright light source (for example sunlight), or
expose the camera to intensive light situations as this may damage the camera pick-up
device.
This information and our technical advice - whether verbal, in writing, or by way of trials
- is given in good faith but without warranty and this also applies where proprietary rights
of third parties are involved. Our advice does not release you from your obligation to
check its validity and to test our products suitability for the intended purpose(s) and
use(s). The application, use and installation of our products either in isolation or in
conjunction with other products used, provided and/or installed by you on the basis of our
technical advice are beyond our control and therefore remain entirely your own
responsibility. Ademco Video products are sold in accordance with our General
Conditions of Sale and Delivery.
ALL DESIGNS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE
© Ademco Video 2000

Setting up the RapidDome Dome
Wiring Details
Mounting
The RapidDome Dome is designed for speed of installation and set up and so the wall
and ceiling mount brackets are supplied pre-wired. Customer wiring is via an internal
terminal block PCB that is located inside the base plastic cover. (See for the location of
the terminal block and for the wiring details.)
The false ceiling versions of the RapidDome Dome are supplied with a 3m cable.
Wall & Ceiling Mount
*
*
54mm 80mm
80mm
82mm 100mm SQ
42mm
12mm WIDE
SLOT FOR
CABLES
ON R30
WALL MOUNT BRACKET
VC5S-WB CEILING MOUNT BRACKETS
161mm
142mm

Mounting Options for RapidDome Dome (including detail of the terminal block)
TWISTED PAIR UP-THE-COAX CONTROL
SG (Not Used) SG (Not Used)
SYN (Not Used) SYN (Not Used)
D+ D+ (Not Used)
D-
Twisted
Pair
Control D- (Not Used)
VID Video Signal VID Video Signal
VG Video Ground VG Video Ground
+V (AC) 24V AC +V (AC) 24V AC
0V (AC) 24V AC 0V (AC) 24V AC
False Ceiling Mount
Wiring Details for the RapidDome Dome (False Ceiling Mount)
TWISTED PAIR ‘DATA IN COAX’
Pin 1 Green 24V AC Pin 1 Green 24V AC
Pin 2 Red 24V AC Pin 2 Red 24V AC
Pin 3 Blue Data + Pin 3 (Not Used)
Pin 4 Yellow Data - Pin 4 (Not Used)
Pin 5 Coax Screen Video Ground Pin 5 Coax Screen Video Ground
Pin 6 Coax Core Video Signal Pin 6 Coax Core Video Signal
Pin 7 (Not Used) Pin 7 (Not Used)
SG
SYN
D+
VID
VG
0V
+V
D-
VC 408
CON2
CON1
CON3
16
4
275
3
Solder side view of
connector fitted on 3
meter su
pp
lied cable

Settings on the RapidDome Dome Top Board
In the following section, please refer to below, for the locations on the board.
The RapidDome Dome Board
LED D2 will illuminate if the receiver that is being controlled by Coax Control is
selected by the transmitter and the coax control code is satisfactory. If the receiver is
being controlled by twisted pair control, LED D2 will flash whenever a valid
command is received.
LK1
OFFON
DILSW1 - Jupiter Microsphere
protocol, address
setting DIL Switch.
18
VC 445V3
TERMINATION
321
VC L
D2 - Sys OK LED
This LED is illuminated if the receiver is being
controlled by Coax telemetry and is selected by the
transmitter. If the receiver is being controlled by
twisted pair, it will flash whenever a valid telemetry
command is received.

Address Settings
The addresses for each Dome are set as shown in the table below. Set the Poles on
DILSW 1 to the desired position for each address.
1 2 3 4 5 6 7 8
Cam
No.
Denotesthe
sw itc h p o sition,
where
= O N &
= O F F
DIL SW ITC H S E TTINGS
1 2 3 4 5 6 7 81 2 3 4 5 6 7 81 2 3 4 5 6 7 8
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
Cam
No. Cam
No. Cam
No.
Denotesthe
sw itc h p o sition,
where
= O N &
= O F F
DIL SW ITC H S E TTINGS
Denotesthe
sw itc h p o sition,
where
= O N &
= O F F
DIL SW ITC H S E TTINGS
Denotesthe
sw itc h p o sition,
where
= O N &
= O F F
DIL SW ITC H S E TTINGS

Coax Control
Up-the-Coax RapidDome Domes do not require an address setting; therefore the settings
of positions 1 - 7 on DILSW1 are ignored. Position 8 controls the alarm feature as
described in Section 7.
LED on the RapidDome Dome Bottom Board
In the following section please refer to below for the locations on the board.
The RapidDome Dome Bottom Board
LED D19 will flash each time a valid control command for this receiver is received.
Alarm Settings
Switch 8 of the 8 way DIL switch (DILSW1: see on page 3) is used to toggle the
RapidDome Domes alarm setting. When the switch is ‘ON’ the RapidDome Domes
alarm inputs are enabled and set to the default settings as shown in the table below. If
switch 8 is ‘OFF’ then the alarms are not automatically enabled, but can be enabled and
adjusted using a MaxCom with local alarm menus. (See the MaxCom instructions for
details of alarm setting menus.)
DATA
D19
D19 - Data Received LED
Flashes whenever a
valid telemetry
command is received

Default Alarm Settings
ALARM INPUT-TYPE PRESET TIME OUT
1 Normally Open 1 10 Seconds
2 Normally Open 2 10 Seconds
3 Normally Open 3 10 Seconds
4 Normally Open 4 10 Seconds
5 Normally Open 5 10 Seconds
6 Normally Open 6 10 Seconds
7 Normally Open 7 10 Seconds
8 Normally Open 8 10 Seconds
When an alarm input becomes active, the RapidDome Dome will move to the
corresponding preset and Relay 1 will close its contacts. When the alarm time-out has
expired the RapidDome Dome will return to its pre-alarm state and Relay 1 will open its
contacts (provided no other alarms have been activated and are still timing out).
Alarm / Relay Connections
The connections to the alarm inputs and relay output are via 2 RJ45 sockets located at the
top of the RapidDome, shown below.

Top View of RapidDome with Alarms
The connections on the RJ45 plugs are numbered as shown below. A suitable termination
tool will be required to connect to the RJ45 plugs.
Contact Side View of RJ45 Plug
The 2 RJ45 connectors are wired as shown in the table overleaf.
CONNECTOR 2 CONNECTOR 3
PIN SIGNAL PIN SIGNAL
1 Alarm in 1 1 Alarm in 5
2 Alarm in 2 2 Alarm in 6
3 Alarm in 3 3 Alarm in 7
4 Alarm in 4 4 Alarm in 8
5 Alarm Common 5 Alarm Common
6 Relay 1 N/O 6 Relay 2 N/O
7 Relay 1 Common 7 Relay 2 Common
8 Relay 1 N/C 8 Relay 2 N/C
(N/O = Normally Open, N/C = Normally Closed.)
Connector 3 Connector 2
1
8
Contacts
Cable
Otros manuales para RapidDome
1
Tabla de contenidos
Otros manuales de Cámara de seguridad de ADEMCO

ADEMCO
ADEMCO RapidDome Guía de inicio rápido

ADEMCO
ADEMCO RapidDome Gold Manual de instalación y operación

ADEMCO
ADEMCO ACM380E Manual de usuario

ADEMCO
ADEMCO ACM574TP Manual de usuario

ADEMCO
ADEMCO AD3VC4HR Manual de usuario

ADEMCO
ADEMCO OptiCAM Manual de usuario

ADEMCO
ADEMCO OptiCAM RJ45 Manual de usuario