ANR-C236N1-K Series
Networking 1U Rackmount Server
• Intel ® C236 PCH
• Intel ® Xeon®E3-1200 V6/Kabylake-S Embeded SKUs
• 12x GbE Copper (4-pair bypass), 1x Mgmt. Port
• 2x 10G Fiber (SFP+)
• 1x Exp. NIM (1G/10G/40G, Fiber/Copper/LAN Bypass)

ANR-C236N1-K Series User Manual
2
Acrosser Technology Co., Ltd.
Disclaimer
For the purpose of improving reliability, design and function, the information in
this document is subject to change without prior notice and does not represent a
commitment on the part of Acrosser Technology Co., Ltd.
In no event will Acrosser Technology Co., Ltd. be liable for direct, indirect, special,
incidental, or consequential damages arising out of the use or inability to use the
product or documentation, even if advised of the possibility of such damages.
Copyright
This document contains proprietary information protected by copyright. All rights are
reserved. No part of this manual may be reproduced by any mechanical, electronic,
or other means in any form without prior written permission of Acrosser Technology
Co., Ltd.
Trademarks
The product names appear in this manual are for identication purpose only. The
trademarks and product names or brand names appear in this manual are the
property of their respective owners.
Purpose
This document is intended to provide the information about the features and use of
the product.
Audience
The intended audiences are technical personnel, not for general audiences.
To read this User Manual on your smart phone, you will have to install an
APP that can read PDF le format rst. Please nd the APP you prefer from
the APP Market.
Ver: 100-002
Date: Sep. 15, 2017

ANR-C236N1-K Series User Manual
3
www.acrosser.com
Table of Contents
1. Introduction ...................................................................5
1.1. Models........................................................................................................................ 5
1.2. Specications ............................................................................................................. 5
1.3. Packing List ................................................................................................................ 7
1.4. Layout & Dimension ................................................................................................... 8
1.5. Front Panel................................................................................................................. 9
1.5.1. Module A: Network expansion module connector ........................................... 9
1.5.2. SFP+ 10GbE LAN Ports ............................................................................... 13
1.5.3. RJ45 2x6 LAN Ports...................................................................................... 13
1.5.4. Console / 2x USB 3.0.................................................................................... 14
1.5.5. LCM Display / Menu Buttons / Indicators ...................................................... 14
1.5.6. HDD Trays..................................................................................................... 14
1.6. Rear Panel................................................................................................................ 15
2. Installation ...................................................................16
2.1. Rack Installaion ........................................................................................................ 16
2.1.1. Required Tools .............................................................................................. 16
2.1.2. Slide-rail Kit Contents.................................................................................... 16
2.1.3. Installing the Server Into a Rack with Slide-rail Kits...................................... 16
2.2. LAN Module Insertion............................................................................................... 19
2.2.1. LAN Module Extraction ................................................................................. 20
2.3. Hard Disk Insertion................................................................................................... 21
2.4. Riser Card Installation .............................................................................................. 22
2.5. LCM Display ............................................................................................................. 26
2.5.1. Board Layout (Model: ADB-LCM3Z1) ........................................................... 26
2.5.2. Connector Pin Denition ............................................................................... 27
2.6. Menu Buttons / Indicators......................................................................................... 29
2.6.1. Board Layout (Model: ADB-FPIOZ1)............................................................. 29
2.6.2. Connector/Button Pin Denition .................................................................... 30
3. BIOS Settings...............................................................32
3.1. Main Setup ............................................................................................................... 32
3.2. Advanced Setup ....................................................................................................... 33
3.2.1. SATA Conguration ....................................................................................... 34
3.2.2. W83627DHG HW Monitor............................................................................. 35
3.2.3. Serial Port Console Redirection .................................................................... 36

ANR-C236N1-K Series User Manual
4
Acrosser Technology Co., Ltd.
3.2.4. Lan Bypass Function..................................................................................... 37
3.3. Chipset Setup........................................................................................................... 37
3.4. Security Setup .......................................................................................................... 38
3.5. Boot Setup................................................................................................................ 39
3.6. Save & Exit Setup..................................................................................................... 39
4. Software Installation and Programming Guide...........41
4.1. Introduction............................................................................................................... 41
4.1.1. Environment .................................................................................................. 41
4.1.2. GPIO ............................................................................................................. 41
4.1.3. Watchdog ...................................................................................................... 41
4.1.4. LAN Bypass Subsystem................................................................................ 41
4.1.5. LCD Control Module ..................................................................................... 41
4.1.6. Power Supply Unit ........................................................................................ 42
4.1.7. Chassis Opened............................................................................................ 42
4.2. File Descriptions....................................................................................................... 43
4.2.1. GPIO/Watchdog/LAN Bypass Subsystem/LCM............................................ 43
4.3. API List and Descriptions ......................................................................................... 43
4.3.1. GPIO ............................................................................................................. 43
4.3.2. Watchdog ...................................................................................................... 44
4.3.3. LAN Bypass Subsystem................................................................................ 44
4.3.4. LCD Control Module...................................................................................... 46
4.3.5. Power Supply Unit (PMBUS) ........................................................................ 49
4.3.6. Pmbus Command Code Summary ............................................................... 49
4.3.7. Power Supply Unit (I2C) ................................................................................ 53
4.3.8. Application Notes for R1V2-5275V/I2C.......................................................... 54
4.3.9. Chassis Opened............................................................................................ 55
4.3.10.Notes............................................................................................................. 55
5. FAQ ...............................................................................57
Q 1. Where can I nd the serial number of this product?................................................. 57
Q 2. How to enable the PXE function?............................................................................. 57

ANR-C236N1-K Series User Manual
5
www.acrosser.com
1. Introduction
The ANR-C236N1-K series is a new product lines of Acrosser 2017. This rackmount
server equips with the latest Intel®server chipset C236 PCH, supporting the latest
Intel®Xeon®E3-1275 V6 server processor, and the 7th generation CPU Kabylake-S
Core i7/i5/i3 series.
The ANR-C236N1-K series provides a more exible server platform & system
expansion versatility with 12x GbE copper LANs (4-pair bypass), 2x 10G ber
networks (SFP+) , expandable network interface modules (Exp. NIM),
Furthermore, in the system backup design, a set of two 2.5-inch hot-swappable HDD/
SSD for RAID0/1 and 1+1 redundant power supply units (RPSU) with AC-IN (100 ~
240V) or DC-IN (48V), enabling reliable options for system recovery.
1.1. Models
This manual is applied to the following models:
1. ANR-C236N1-K2D0T
2. ANR-C236N1-K2D00
3. ANR-C236N1-K1D00
1.2. Specifications
System
Thermal Solution • Smart Cooling Fans
CPU • Intel®Xeon®E3-1275 v6
• Intel®Kabylake-S 7th Gen Core™ i7-7700
• Intel®Kabylake-S 7th Gen Core™ i5-7500
• Intel®Kabylake-S 7th Gen Core™ i3-7101E
System Memory • 4x UDIMM DDR4-2400 (up to 64GB)
BIOS • Support Console Re-direction
• Support Bypass Setting
Status Normal Bypass
SYS (ON) V
SYS (OFF) V
WDT (Timeout) V
PWR (Lost) Remained prior status
• Support Boot from RJ45 LAN[1:12]
System Chipset • Intel®PCH C236

ANR-C236N1-K Series User Manual
6
Acrosser Technology Co., Ltd.
Network Interface
Ethernet (on-board) • 12 Copper, 0/2 SFP+, 0/1 Mgmt.
• Intel®I210-AT, LAN[1:8]
• Intel®I350-AM4, LAN[9:12]
• Intel®X710-BM2 (10G Fiber), SFP+[1:2]
• Mgmt. (via GbE LAN[1] Copper)
LAN bypass (4-pair) • (1st LAN bypass) by LAN[5:6]
• (2nd LAN bypass) by LAN[7:8]
• (3rd LAN bypass) by LAN[9:10]
• (4th LAN bypass) by LAN[11:12]
Storage
HDD Bay • 2x 2.5” Hot-swappable (for RAID 0/1)
mSATA • 1x mSATA Socket (Support full-size module)
CFast • 1x CFast Socket
Others
Watchdog Timer • Software Programmable 0 ~ 255 Secs.
Battery • Lithium Battery, 3V 220mAH (CR2032)
Hardware Monitoring • CPU Voltage
• CPU & SYS Temperature
• SYS FAN Speed
Security & Mgmt. • On-board TPM 1.2 (default) / 2.0 (optional)
• IPMI 2.0 Compliance
• Chassis Intrusion Detection (default: Disable)
OS support • Linux Kernel 4.4 or above, (64-bit)
Mechanical & Environment
Chassis Dimension • 440 (W) x 44 (H) x 500 (D) mm
Operating Temperature • 0 ~ 40°C (32 ~ 104°F)
Storage Temperature • -20 ~ 80°C (-4 ~ 176°F)
Relative Humidity • 0 ~ 90% @40°C, non-condensing
Power Supply Unit • 1+1 ATX PSU (250W~300W)
• 1+Dummy ATX PSU (250W~300W)
• Single ATX PSU (250W~300W)
Power Requirements • ATX Circuit as AT Mode with Power Switch

ANR-C236N1-K Series User Manual
7
www.acrosser.com
Mechanical & Environment
Certication • CE, FCC Class A, RoHS 2, cULus
Vibration Test • IEC 60068-2-64, 5~500Hz, 3GRMS
Drop Test • ISTA-2A 2006
1.3. Packing List
Check if the following items are included in the package.
Item Q’ty
�ANR-C236N1-K Series System 1
�SATA Cable 2
�Driver CD 1
�Console Cable (RJ45) 1
�Power Cord 2
�Rack Bracket 2
�Packing Box 1
�Screw Pack 1
�Heatsink Module (for Barebone) 1

ANR-C236N1-K Series User Manual
8
Acrosser Technology Co., Ltd.
1.4. Layout & Dimension
(Illustration model: ANR-C236N1-K2D0T)

ANR-C236N1-K Series User Manual
9
www.acrosser.com
1.5. Front Panel
1.5.1. Module A: Network expansion module connector
Available LAN Modules:
Note: The model name, type number, or layout design of these options might change due
to product revision.
1. ACC-NM1Z1-01C8B: 1G Copper x8 (RJ-45 w/ 4-pair Bypass)
2. ACC-NM1Z1-01C8: 1G Copper x8 (RJ-45)

ANR-C236N1-K Series User Manual
10
Acrosser Technology Co., Ltd.
3. ACC-NM1Z1-01F8: 1G Fiber x8 (SFP)
4. ACC-NM1Z1-01H8B: 1G Hybrid x8 (SFP + RJ-45 w/ 2-pair Bypass)
5. ACC-NM1Z1-01H8: 1G Hybrid x8 (SFP + RJ-45)
6. ACC-NM1Z1-10F2: 10G Fiber x2 (SFP+)
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Servidor de Acrosser Technology

Acrosser Technology
Acrosser Technology AR-R5800 Manual de usuario

Acrosser Technology
Acrosser Technology AAD-C622A Series Manual de usuario

Acrosser Technology
Acrosser Technology ANR-C62 N1Series Manual de usuario

Acrosser Technology
Acrosser Technology AND-APL1E Series Manual de usuario

Acrosser Technology
Acrosser Technology ANR-C62-N1 Series Manual de usuario

Acrosser Technology
Acrosser Technology ANR-DNV3N3 Series Manual de usuario

Acrosser Technology
Acrosser Technology ANR-SKB2N ACN Series Manual de usuario