ACLAS PS1X Manual de usuario

PS1X PRICE COMPUTING SCALE
USER MANUAL


Important Safety Information
1) Please read these safety instructions carefully.
2) Keep this user manual for later reference.
3) This product meets the relative requirements of the national standard IEC 60950: 2001 ‘Safety of information technical
equipment’.
4) Thunder can hurt this product and even your personal safety, so please pull out the network cable and other conductor
connecting external attachment in thunder days.
5) Please don’t spatter any sundries or liquid into the machine; please don’t stuff anything inside this product, otherwise
it may cause short circuit.
6) Please be sure not to change the battery with a wrong type one, otherwise there is danger of explosion. Be sure to deal
with used battery with the way of dealing with waste battery.
7) Please lay this product packed in the 10-40℃ environment for at least 2 hours before turning on if it was stored in less
than 10℃ temperature environment during the transportation, so as to avoid the damage on the product due to a big
change of environmental temperature.
8) Please don’t throw anything on this product or hit against it.
9) Please do not allow children to climb up on the product, in case the product drops and hurt them.
10) Switch off the product if you will not use it in a long time.
11) The non-experts or non-authorized people please don’t open the machine shell.
STATEMENT
More information about software, driver, etc. please download from:
http://download.aclas.com/en/index1.html

CONTENT
Unique Functions................................................................................................................... 1
Excellent Functions ...............................................................................................................1
Accessories.............................................................................................................................. 1
Technical Specification..........................................................................................................2
Appearance and Dimension..................................................................................................3
The Installation of Customer Display..................................................................................4
Operation................................................................................................................................ 7
7.1 Function Keys Operation ................................................................................................................... 7
7.2 Further Functions Explanation ......................................................................................................... 8
7.2.1 Diagram of Basic Operation Process................................................................................................. 8
7.2.2 Unit Price Setting Function................................................................................................................ 8
7.2.3 Give Change Function ........................................................................................................................ 9
7.2.4 Tare Function ...................................................................................................................................... 9
7.2.5 Pending order & Accumulation Function......................................................................................... 9
7.2.6 Sleep Mode Function ........................................................................................................................ 10
7.2.7 Backlight Setting ............................................................................................................................... 10
Calibration ........................................................................................................................... 11
8.1 Destroy the Sealing.............................................................................................................................11
8.2 Fine Adjustment of Gravity Acceleration Compensation Value................................................... 12
8.3 Adjustment of Gravity Acceleration Compensation Value ........................................................... 13
8.4 Zero/Full Weight Learning Methods............................................................................................... 14
Contact Us ............................................................................................................................ 14

1
Unique Functions
➢Unique super power-saving design, 3 pieces of D batteries support 2-year working (working condition:
8 hours/day, 30 times/hour, 10 seconds/weighing).
➢Unique multi-customer accumulating function (patent), enables simultaneous service for 5 customers.
Powerful function makes one scale used as five scales.
➢Insect-proof design (patent) prevents insect’s entrance, effectively reducing 80% scale failure rate.
➢Auto power-saving design with vibration-detect mechanism, scale can quickly wakeup from standby
(21μA) and return to working mode by any loading or key touching.
➢Cost saving: 3 pieces of D batteries works for 2 years. Compared to traditional rechargeable battery, it
is lower costing and no need of professional maintenance.
➢High-sensitive light touch keyboard and super life-long carbon membrane.
➢Daily total turnover check function.
➢The most feature-rich in redisplay function, able to redisplay the transaction process which including
unit price, piece weight, total price, price unit and serial number, clearer than other scales in market.
➢High-resolution 3-line LCD display, able to display weight, unit price and total price in the same screen.
➢Well-designed combined function keys, convenient and easy to operate.
Excellent Functions
➢High anti-interference. The radiation intensity to radio frequency electromagnetic fields up to 10v/m.
➢Auto-power saving design, will enter the stand-by status automatically without any operation (user-
defined 4~200 seconds at will, 200 seconds won’t enter auto-power saving status) only consuming
21μA, able to be awake by any loading or operation due to the inner shaking mechanism. (Please tap
the platter when there is no response in loading).
➢Adjustable backlight level: Users is able to adjust the backlight brightness according to actual need.
➢CHG function, make sure to give accurate change.
➢Price Lock function, easy to sell item in same price.
Accessories
1) Main Set
2) Stainless Platter
3) User Manual
4) Battery

2
Technical Specification
Module
PS1XB
Basic Features
With backlight
Accuracy Class
Weighing Capacity (Max.)
15lb/30lb; 30lb/60lb
Verification Scale Interval
0.005lb/0.01lb; 0.01lb/0.02lb
Weighing Capacity (Min.)
0.1lb; 0.2lb
Tare (Max.)
-9.995lb; -29.99lb
Power Supply
3 pcs D batteries
Battery Estimated Use Time
Approximate 2 years (8 hours/day, 30 times/hour, 10
seconds/weighing)
Power Consumption
Soft shutdown < 5μA, Stand by: 21μA,
Working: 4.6mA,
Backlight on: <5.5mA
Working Temperature
0℃-40℃
Platter Size
Stainless steel tray: 330*230 mm
Note:
The machine is shipped with 3pcs battery. Please remove the battery’s insulating strip before use.

3
Appearance and Dimension
Pole Type (Unit: mm):
Bench Type (Unit: mm):

4
The Installation of Customer Display
1. Take out the fix set,open the LCD cover and loose the four screws of display pole.
Display Pole
Screw
Fix Set
Front Cover
Back Cover
2. Take out the FFC.
FFC
3. Insert the FFC cable through the display
pole as the arrow shows.
4. Fix the display pole on the scale platter.

5
7. Remove the tape circled in the picture and
stick it aside.
8. Open the FFC socket lock, plug and lock the
FFC cable. (Note: Keep blue side upper).
5. Tighten the four screws.
6. As shown, put on the fix set (“A" side down).
Fix Set of
Display Pole
“A” Side of Fix Set (down)

6
11. Assemble the display as shown in above pictures.
12. Put on the fix set. The whole installation
is finished.
Attention: after putting on the fix set,
lift the display slightly to ensure
that the display firmly fixed on the
display pole.
9. Fix the FFC with the tape.
10. Fix the front cover (with LCD) on display pole.
Insert the FFC through the pole, straighten the cable
then fixing.
Insert “A” column
into hole “B”
A
B
Otros manuales para PS1X
1
Tabla de contenidos
Otros manuales de Escala de ACLAS