ABB Rellon 620 Series Manual de usuario

Relion® 620 series
RER620
IEC 60870-5-101/104 Communication
Protocol Manual


Document ID: 1MAC306892-MB
Issued: 07/20/2017
Revision: C
Product version: 1.3
© Copyright 2017 ABB. All rights reserved.

Copyright
This document and parts thereof must not be reproduced or copied without written
permission from ABB, and the contents thereof must not be imparted to a third party, nor
used for any unauthorized purpose.
The software or hardware described in this document is furnished under a license and may
be used, copied, or disclosed only in accordance with the terms of such license.
Trademarks
ABB and Relion are registered trademarks of ABB Group. All other brand or product
names mentioned in this document may be trademarks or registered trademarks of their
respective holders.
Warranty
Please inquire about the terms of warranty from your nearest ABB representative.
ABB Inc.
Distribution Automation
4300 Coral Ridge Drive
Coral Springs, FL 33065, USA
Toll-free: 1 (800) 523-2620
Phone: +1 954-752-6700
Fax: +1 954 345-5329
http://www.abb.com/substationautomation

Disclaimer
The data, examples and diagrams in this manual are included solely for the concept or
product description and are not to be deemed as a statement of guaranteed properties. All
persons responsible for applying the equipment addressed in this manual must satisfy
themselves that each intended application is suitable and acceptable, including that any
applicable safety or other operational requirements are complied with. In particular, any
risks in applications where a system failure and/or product failure would create a risk for
harm to property or persons (including but not limited to personal injuries or death) shall
be the sole responsibility of the person or entity applying the equipment, and those so
responsible are hereby requested to ensure that all measures are taken to exclude or
mitigate such risks.
This document has been carefully checked by ABB but deviations cannot be completely
ruled out. In case any errors are detected, the reader is kindly requested to notify the
manufacturer. Other than under explicit contractual commitments, in no event shall ABB
be responsible or liable for any loss or damage resulting from the use of this manual or the
application of the equipment.

Conformity
This product complies with the directive of the Council of the European Communities on
the approximation of the laws of the Member States relating to electromagnetic
compatibility (EMC Directive 2004/108/EC) and concerning electrical equipment for use
within specified voltage limits (Low-voltage directive 2006/95/EC). This conformity is
the result of tests conducted by ABB in accordance with the product standards EN 50263
and EN 60255-26 for the directive, and with the product standards EN 60255-6 and EN
60255-27 for the directive. The protective relay is designed in accordance with the
international standards of the IEC 60255 series and ANSI C37.90

1MAC306892-MB C Section
RER620 1
Communication Protocol Manual
Table of Contents
Section 1 Introduction........................................................................... 5
This manual.............................................................................................. 5
Intended audience.................................................................................... 5
Product documentation ............................................................................ 6
Product documentation set ................................................................. 6
Document revision history................................................................... 7
Related documentation ....................................................................... 7
Symbols and conventions ........................................................................ 7
Safety indication symbols.................................................................... 7
Manual conventions ............................................................................ 8
Section 2 IEC 60870-5 overview .......................................................... 9
IEC 60870-5 protocol ............................................................................... 9
Transmission ............................................................................................ 9
Unbalanced transmission.................................................................. 10
Balanced transmission ...................................................................... 10
Basic application functions ..................................................................... 10
Data acquisition................................................................................. 10
Event acquisition ............................................................................... 11
Interrogation ...................................................................................... 11
Clock synchronization ....................................................................... 11
Command transmission .................................................................... 11
Changes in protocol and link parameters.......................................... 12
Acquisition of transmission delay ...................................................... 12
Analog Value Deadband ................................................................... 12
Section 3 Vendor-specific implementation ......................................... 13
615/620 series implementation .............................................................. 13
Internal IEC 61850 data modeling..................................................... 13
Instances........................................................................................... 13
Selecting between IEC 60870-5-101 and IEC 60870-5-104 ............. 13
Configuring ............................................................................................. 13
Configuring IEC 60870-5-101 ........................................................... 14
Configuring IEC 60870-5-104 ........................................................... 14
Troubleshooting ................................................................................ 15
Event overflow handling ......................................................................... 15
Overflow mode .................................................................................. 15
Overflow indication addresses .......................................................... 15
Overflow situation clearing ................................................................ 16
Supported data types ............................................................................. 16

Section 1MAC306892-MB C
2 RER620
Communication Protocol Manual
Indications (MSP, MDP) .................................................................... 16
Measurements (MMENA, MMENB, MMENC, MMEND) ................... 16
Control objects (CSC, CDC).............................................................. 16
Addressing scheme ................................................................................ 17
Default addresses ............................................................................. 17
Configuring communication options .................................................. 17
Communication parameters ................................................................... 17
Port.................................................................................................... 17
ClientIP.............................................................................................. 17
End delay .......................................................................................... 18
Device address.................................................................................. 18
ASDU address................................................................................... 18
Link mode.......................................................................................... 19
COT length ........................................................................................ 19
OA length .......................................................................................... 19
Link address length ........................................................................... 19
ASDU address length........................................................................ 19
Single character response................................................................. 20
Show bad time................................................................................... 20
Time format ....................................................................................... 20
Event time ......................................................................................... 21
Overflow mode .................................................................................. 21
OvInd IOA.......................................................................................... 21
OvInd NoGI IOA ................................................................................ 21
Event order........................................................................................ 22
Selection time-out.............................................................................. 22
Cyclical period ................................................................................... 22
Transmit window ............................................................................... 23
Receive window ................................................................................ 23
Transmit timeout................................................................................ 23
Receive timeout................................................................................. 23
Link test interval ................................................................................ 24
Diagnostics ............................................................................................. 24
Status ................................................................................................ 24
Received frames ............................................................................... 24
Transmitted frames ........................................................................... 24
Physical errors................................................................................... 24
Link errors ......................................................................................... 24
Transport errors................................................................................. 25
Section 4 IEC 60870-5-101 and IEC 60870-5-104 parameters.......... 27
Parameter list ......................................................................................... 27
Monitored data........................................................................................ 29

Section 1MAC306892-MB C
4 RER620
Communication Protocol Manual
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Relé de ABB










































