Zip Micro BC Manual

1
806393 v1.08 09.19 Micro Install Instructions
Installation instructions & user manual
Zip Micro
Instant Boiling and Chilled water.
Models:
Micro B (Boiling), Micro BC (Boiling/Chilled)
AFFIX PRODUCT LABEL HERE

2 806393 v1.08 09.19 Micro Install Instructions

03
806393 v1.08 09.19 Micro Install Instructions
Contents
WARNINGS AND PRECAUTIONS................................................. 04
Major components and accessories ............................................06
Technical specification ...............................................................07
Before Installation ......................................................................08
Installation instructions..............................................................09
Step 1 – Tap installation .............................................................09
Step 2 – Ventilation ....................................................................10
Step 3 – Command centre installation ........................................11
Step 4 – Commissioning ............................................................14
Operation................................................................................... 16
Tap operation .............................................................................16
Energy mode .............................................................................. 17
Maintenance .............................................................................. 18
Water filter.................................................................................. 18
Air inlet filter (Boiling/Chilled model) ....................................... 20
Troubleshooting..........................................................................21
Cleaning ..................................................................................... 23
End of life disposal ..................................................................... 23

04 806393 v1.08 09.19 Micro Install Instructions
1. WARNING: For continued safety of this appliance it must be
installed, operated and maintained in accordance with the
manufacturer’s instructions.
2. Plumbing and electrical connections must be made in accordance with
local regulations and relevant standards. In Australia: Plumbing standard
AS/NZS 3500 series & Electrical Wiring Rules AS/NZS 3000.
3. For residential chilled models, all refrigeration must comply with AS/NZS
60335.2.24.
4. This appliance must be earthed.
5. The power cord and general power outlet must be in a safe and accessible
position after installation.
6. Do not remove the cover of the appliance under any circumstances
without first isolating the appliance from the power supply.
7. This unit is designed for indoor use and must not be installed outdoors or
exposed to the elements of nature.
8. This appliance must not be cleaned by a water jet. This appliance must
not be positioned in an area that may be cleaned by a water jet.
9. This appliance is intended to be used in: staff kitchen areas in shops, offices
and other working environments; farm houses and by clients in hotels,
motels and other residential type environments; bed and breakfast type
environments; catering and similar non-retail applications.
10. Due to the process of continuous improvement, Zip reserves the right
to change details in this manual, without notice. Visit zipwater.com to
ensure you have the latest copy of this document.
Safety
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. For products sold in Europe,
this appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of
WARNINGS AND PRECAUTIONS
!

05
806393 v1.08 09.19 Micro Install Instructions
the appliance in a safe way and understand the hazards involved. Children should
be supervised to ensure that they do not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
Refrigerant (BC model)
The HydroTap Micro (BC model) contains R134A refrigerant under pressure.
Maintenance of the refrigeration unit must be carried out by an accredited service
provider or qualified refrigeration technician.
Qualifications
If the power cable is damaged it must be replaced by a qualified technician. To
avoid hazards, all installation procedures must be carried out by a suitably qualified
tradesperson.
Venting
Occasionally steam and / or boiling water may discharge through a vent outlet on
the tap. Ensure the tap body is located so the tap outlet safely dispenses into the
drip tray or sink bowl area.
Lifting
Take care when lifting. The Micro command centre may exceed safe lifting limits. If
you feel this is beyond your personal capabilities, please seek assistance with the lift.
Do not lift the Micro command centre by the front cover or any of its connections.
Refer to the Technical specification for the weight of the product.
Airflow
The ambient operating temperatures, when installed in a cupboard, must be
between 5°C - 35°C. The system will operate satisfactorily only if the recommended
air gaps of 50 mm on each side, and 200mm above the command centre are
provided. If a vent kit is supplied, it is recommended to be fitted according to these
instructions.
Frost Protection
If this appliance is located where the ambient air temperature could fall below
5°C when the heater is not in use, do not turn off the appliance electrically. This
safeguard does not offer the same protection to the connecting pipework and
fittings.
WARNINGS AND PRECAUTIONS

06 806393 v1.08 09.19 Micro Install Instructions
Accessories Description
Replacement
filter
part no:
93701 (0.2 micron)
Font and tap
extension kit
part no:
95162 (Chrome)
95163 (Matte Black)
Water block
part no. 95136
Parts supplied Description
Micro Tap
and hoses
part no:
94873 B hoses (x2)
94863 BC hoses (x3)
94063 tap fixing kit
Micro command
centre, including
water filter
350 kPa PLV
part no. 90833
Braided hose for
mains water (1m)
part no. 95006
IEC power cable
(1.8m)
part no. 94704
1/4” filter flush
hose (1m)
part no. 91025
Install
Instruct
Installation
instructions
(this book)
Major components and accessories
Parts supplied Description
For BC model:
Vent Kit
1 x inlet, 1 x outlet
9 x screws
part no. 93257
• Allen key
• Tube spanner
• Filter flush key
• 4x 6mm adhesive door buffers
• Tap operation label

07
806393 v1.08 09.19 Micro Install Instructions
Technical specification
Note 1 cup = 167 mL, 1 glass = 200mL.
An optional water block may be fitted in the water supply line to minimise the
potential damage in the event of leakage. Contact your local service centre.
Model: Micro B
(Boiling)
Micro BC
(Boiling Chilled)
Rated Voltage/Power 220-240V, 50Hz, 1.39 kW
220V, 60Hz, 1.23 kW 220-240V, 50Hz, 1.52 kW
Rated mains inlet water pressure 150 - 700 kPa
Water connection ½” BSP (G ½”)
Ambient operating temperature 5 - 35 °C
Boiling water temperature setpoint 98°C
Boiling water performance 15 L (90 cups) per hour
Chilled water temperature setpoint – 6 - 8°C
Chilled water coolant – R134a
Chilled water performance -
Commercial installations – 12 L (60 glasses) per hr
Chilled water performance -
Residential installations – 2.4L (12 glasses) per hr
Dimensions (W x D x H) (mm) 180 x 270 x 340 180 x 502 x 340
Dry weight (command centre) 9 kg
(+1.8kg when filled)
15.6 kg
(+3.6kg when filled)

08 806393 v1.08 09.19 Micro Install Instructions
Before installation, ensure that:
• All technical specifications and instructions have been reviewed.
• The underbench can support the product weight when full of water (see
Technical specification).
• There is sufficient space in the cupboard to install the command centre
and other components in accordance with these installation instructions.
• A user easily-accessible 220-240V AC, 10A power outlet is required.
The appliance must be connected in accordance with current
local electrical regulations. See Technical specification for
power ratings. Check cable and plumbing against inlet /outlet
positions before proceeding.
• Potable water supply with working pressure of 150 - 700 kPa (1.5 - 7.0 bar),
with isolating valve within reach of the hose and positioned so that the
valve will not be obstructed.
• A 350 kPa (3.5 bar) pressure limiting valve, which also functions to prevent
backflow of water into the water mains (supplied) must be fitted.
• The appliance must be placed upright with its base in a horizontal position.
IMPORTANT! Do not proceed with the installation if these
requirements are not met.
!
Before Installation
!

09
806393 v1.08 09.19 Micro Install Instructions
Installation instructions
Step 1 – Tap installation
Micro Tap
Washer
Benchtop
Nut
Spider clamp
Spacer
Spider clamp
CLEAR hose (vent)
RED hose (boiling)
1Position the Micro Tap so that
water from its spout will fall into
a sink/drip tray fitted with a drain.
Cut a 35mm hole into the sink or
benchtop, using a sheet metal
punch or hole saw (not supplied).
max 40mm
The tap must not be installed
more than 900 mm above
the base of the command
centre. Failure to do this may
result in poor water delivery.
2
3
View from
below the tap.
Connect the silicone
hoses to the tap
tubes.
Push the hose 20mm
over the tube. Fasten
with a hose clamp.
BC model
BLUE hose
(chilled)
From above the
bench, pass hoses
down through
the hole. Push
spacer on to the
base of the tap.
A light smear of
silicone sealant
under the spacer is
recommended for
a watertight fit.
From below the bench, assemble
washer, spider clamp and fastening
nut. Check the tap is in the correct
position before tightening the nut.
max 900mm
Ø 35mm
hole

10 806393 v1.08 09.19 Micro Install Instructions
1
Installation instructions
Step 2 – Ventilation
Cool air IN
Warm air
OUT
Fit the silicone door buffers to the
inside edge of the cupboard door to
provide an air space. The top and front
of the command centre must remain
accessible for servicing.
2
(Boiling/Chilled models) Install the cupboard floor inlet vent
(supplied) in the cupboard where the command centre is located.
Refer to the instructions supplied with the vent kit.
If cupboard temperature rises above 35°C
The outlet vent may be installed in the door or wall. If additional
ventilation is required, please contact your local service centre for
more details.
4
!
3
Outlet vent may
be installed, if
required, in the
door or wall.
IMPORTANT: Allow a minimum clearance envelope of
50mm either side, and 200mm above the command
centre. Proper air circulation must be provided for the
system to operate correctly.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Dispensador de agua de Zip

Zip
Zip HydroChill HCF090 Manual

Zip
Zip ZT400 Manual de lista de piezas

Zip
Zip HydroTap G4 Manual de usuario

Zip
Zip 801623 Manual de usuario

Zip
Zip HC03CTU15 Manual

Zip
Zip HydroTap G4 Manual de usuario

Zip
Zip HYDROCHILL HC20 Series Manual

Zip
Zip Hydroboil Duo 310111 Manual

Zip
Zip HydroTap G4 Manual de usuario

Zip
Zip Classic HydroTap G4 range Manual de usuario