ŸActivate - This mode is like having a remote-
control thermostat. Technicians often use it
when the thermostat is not easily accessible:
when making a diagnosis or repair to a unit in
an attic, basement, roof, or new construction
where the thermostat hasn’t been installed
yet.
2.) Hook-Up - Start with the mode switch in the
ANALYZE position and have all component
switches OFF. The hookup of the ZebraStat’s
leads is the same for all modes. Connect the
leads to their respective wires at the equipment.
(Common uses of wire colors are listed below
the component switches. However, you can use
any of the wires to test any other 24V function,
like ‘Emergency Heat.’) Connect the red and
blue leads to the equipment’s 24V power,
observing polarity. All modes, except
ANALYZE, require that all thermostat functions
be OFF.
3.) & 4.) Manipulate Controls & Observe
LED’s & Equipment. See the following
sections (Continuity, Analysis, or Activation) for
the proper steps to follow next.