YILKAR YK 60 S Additional Manual de usuario

YK 60 S Additional
YILKAR
Installation Instruction
SSH.MT.01.05 - EN
The right to make changes is reserved. Printed in Turkey. © Yılkar Airconditioned, 2023
EN

SSH.MT.01.05 - EN
The right to make changes is reserved. Printed in Turkey. © Yılkar Airconditioned, 2023
00
09.02.2022
H.Kübra Şahin
First Publication
REVISION NO
PUBLISH DATE
REVISING PERSON
REASON FOR REVISION

Contents
2
1
3
6
8
4
8
13
16
7
6
11
11
11
3
16
19
21
19
23
4
4
5
9
6
16
17
17
24
24
24
24
SSH.MT.01.05 - EN
The right to make changes is reserved. Printed in Turkey. © Yılkar Airconditioned, 2023
1. Introduction .........................................................................................................
4.Installation of Yılkar YK 60 S Additional ................................................................
3.1 YK 60 S Additional Overview ......................................................................
4.3 YK 60 S Additional Unit Mounting ............................................................
4.3.1 Additional Unit Dimensions ...........................................................
4.3.2 Additional Unit Roof Mounting .......................................................
1.2.1 ECE R-10 .......................................................................................
2.1 What is the YK 60 S Additional ..........................................................
2.2 How does it work? .............................................................................
2.3 YK 60 S Additional Technical Data ....................................................
4.2 YK 60 S Additional U Connection Profiles Mounting ................................
3.1.1 YILKAR Split Unit ............................................................................
1 Warranty and Liability ...............................................................................1.
1.2 Security and Legal Regulations ...............................................................
2. Definition and Technical Information ..................................................................
3.Overview................................................................................................................
3.2 General Description.....................................................................................
4.1 General Assembly Diagram ......................................................................
4.4 Hoses and Fitting .....................................................................................
4.4.1 Air Conditioner Hoses and Fitting Connections..............................
4.4.1.1. Air Conditioner Hoses .......................................................
4.4.1.2. Fitting Sets ........................................................................
4.4.1.3. Clamp and Plastic Adapters ..............................................
4.4.1.4. Hose and Fitting Mounting ..............................................
4.5 Electrical Connections ..............................................................................
4.5.2 Wiring and Circuit Diagram ...........................................................
4.5.1 Control Unit Mounting ..................................................................
4.5.3 Control Unit Owerview ...................................................................
4.5.4 Control Unit Operation ...................................................................
4.5.4.2 Heating (Optional) ...............................................................
4.5.4.3 Ventilating ...........................................................................
4.5.4.1 Cooling ...............................................................................

26
27
27
30
28
SSH.MT.01.05 - EN
The right to make changes is reserved. Printed in Turkey. © Yılkar Airconditioned, 2023
5. Commissioning the Air Conditioner ......................................................................
6. Spare Parts ...........................................................................................................
7. Usage and Maintenance Recommendations ........................................................
6.1. Evaporator Spare Parts ............................................................................
6.2. Other Spare Parts .....................................................................................

1
1. Introduction
This instruction is part of the YK 60 S Additional air conditioner. All necessary
information for installation is explained and includes information on safe use of the
device. Please read this installation instruction carefully in order to fully install Yılkar air
conditioner.
It is recommended to be stored in a safe and clean place.
For questions, please contact the service and/or customer service.
You can scan the QR code for Yılkar Klima communication.
EN

2
Warranty conditions
YILKAR assures its customers that the products they buy are manufactured in
accordance with today's technology and without any errors. All YILKAR Authorized
Dealers are obliged to carry out warranty transactions regardless of which authorized
dealer the vehicle is sold by.
All parts on the product are under warranty for 2 (two) years from the date of delivery in
case of fabrication defects.
If the relevant warranty form indicating that the product was installed at the approved
service points is not found in the business records, the date when the product was
decommissioned is taken as a reference. As of the date of exit from the business, the
warranty is processed for 2 years (two years).
Consumables (belt, bearing, refrigerant, workmanship, filter, dryer and compressor) are
covered by warranty for 1 year or 50,000 km (whichever comes first) from the date of
installation of the product.
In case the product fails during the warranty period, the time spent in repair is added to
the warranty period. This period starts with the delivery of the product to the authorized
service. The repair period of the product is maximum 30 days.
The warranty does not apply in the following cases:
Defects arising from the use or assembly of the product contrary to the points in the user
manuals
Faulty electrical wiring
Damages and malfunctions caused by using a voltage different from the voltage written
on the label of the product
If the product maintenance and repairs are not carried out on time, regularly, by the
services with the necessary technical knowledge and competence and in accordance
with the periodic maintenance and repair procedures (Every 50,000 km and annual
maintenance is obligatory).
The ownership of the parts changed within the warranty belongs to YILKAR.
The warranty period of products replaced by spare parts is 1 (one) year from the date of
installation.
1.1 Warranty and Liability
EN

3
1.2 Security and Legal Regulations
Read this service manual carefully before operating your YK 60 S Additional model roof type air
conditioner.
In case of problems that may occur as a result of improper use conditions, the warranty is
canceled and compensation claims are not taken into account.
Have repair and maintenance operations performed only by qualified personnel
who have received the necessary training and authorization. You can find
information about YILKAR authorized service centers on YILKAR's official website,
www.yilkarklima.com.
Do not reach into the unit and do not hold any foreign objects to the condenser and
evaporator fan when the device is in operation.
Please do not touch the condenser, evaporator or its connections with your hands.
The same is true for the resistor on the fan if it will run on the unit and it has not
cooled down completely.
Replace faulty parts immediately and have any detected faults corrected.
It is mandatory to use the necessary safety equipment in maintenance and repair
operations.
Carry out maintenance work only when the engines are turned off.
Before turning on the air conditioning unit, disconnect the battery.
Please pay attention to the following rules for your own safety:
ECE R10 – Electromagnetic compatibility regulation is the type approval test for European
automotive electronics. It has been successfully passed various tests including RF immunity
and emissions, transient immunity and emissions.
Electrically it has met the requirements for waste, explosion, fluctuating harmonics and
vibration.
As a result of the tests, it was certified with the document number E13 R10 - 05 13505.
You can reach Yılkar Klima ECE-R 10 test certificate via the QR code below.
1.2.1 ECE-R 10
EN

4
YK 60 S additional is an innovative designed air conditioning device developed for air
conditioning minibuses up to 15 seats.
The easy-to-install unit includes an evaporator. These units must be mounted on the roof
of the vehicle and connected to the compressor via hoses circulating R134a refrigerant.
It can operate in outdoor conditions at 45°. The air conditioner, which has a cooling
capacity of 2-6 kW, can have a heating function with the heat exchanger device. Your air
conditioner makes the waste heat generated in your vehicle's engine usable and can
provide heating power to your air conditioner with its current design. In this way, the
cooling of your engine is more effective, while your vehicle warms up.
YK 60 S is universal, compact and economical with all its features.
2. Definition and Technical Information
2.1 What is YK 60 S Additional?
2.2 How does it work?
Vehicle roof air conditioners are heat machines that provide passenger thermal comfort
by taking the heat inside the vehicle.
Vehicle roof air conditioners work with a vapor compression refrigeration cycle in
thermodynamics. There are 4 main parts in this cycle. These are the compressor,
condenser, evaporator and expander valve.
The refrigerant put into the heat machine is first pressurized in the compressor, and the
fluid pressure is increased from approximately 1 bar to 16 bar. Afterwards, the
temperature of the supercompressed and superheated gas in the condenser is taken and
the fluid is liquefied under extreme pressure. The high pressure liquefied fluid coming to
the expansion valve from here passes through the valve to the low pressure region and
evaporates. It needs heat during evaporation. While the ambient air passed over the
evaporator heats the fluid in the evaporator and causes it to evaporate, it cools the
environment and provides thermal comfort to the passenger cabin.
EN

Roof Type Air Conditioning Unit
YK 60 S Additional
Cooling Power
2-6 kw
(6824 - 20472 BTU/h)
(1720 - 5159 kcal/h)
Oil Type
PAG 100 oil
Oil Amount
250 ccm
Refrigerant / Amount
* R 134 a / 500 ± 150 gr
Evaporator Fan Flow Rate
1000 m³/h (for 1 Blower Motors)
Dimensions
(Length x Width x Height)
610 x 420 x 226 mm
Weight (Without Mounting Kit)
8 kg
Maximum Total Electricity Intake
18 A @12 VDC
9 A @24 VDC
2.3 YK 60 S Additional Technical Data
5
*It is the value that should be added to the gas amount of the original air conditioner.
*Depends on the features of the additionally connected master air conditioning system.
Table.1 Technical Data
EN

1
3
4
2
1
EVAPORATOR UNIT - YK 60 S
1 PCS
311.02.YK060.01
2
AIR SUCTION GRILL COMPLETE - 1 - BLACK
1 PCS
501.24.HEIPL.14
3
HOSE - STEEL WIRE - SPIRAL 12 MM
6 MT
108.02.HC00M.12
4
U - DOUBLE - RAIL-EAR 70 CM COMPLETE
1 SET
502.51.UC005.01
3. Overview
3.1 YK 60 S Additional Overview
6
3.1.1. YILKAR Splt Unt
EN
Otros manuales para YK 60 S Additional
1
Tabla de contenidos
Otros manuales de Acondicionador de aire de YILKAR

YILKAR
YILKAR YK 400 Manual de usuario

YILKAR
YILKAR YK 300 Manual de usuario

YILKAR
YILKAR Montaj Talimati YK 190 MB L Manual de usuario

YILKAR
YILKAR YK 80S Manual de mantenimiento

YILKAR
YILKAR YK 140 MB Additional Manual de usuario

YILKAR
YILKAR YK 120 S Additional Manual de usuario

YILKAR
YILKAR YK 100 S Manual de usuario

YILKAR
YILKAR YK 90 S Additional Manual de usuario

YILKAR
YILKAR YK 120 S Manual de usuario

YILKAR
YILKAR YK 80 S Manual de usuario