YASKAWA 1000 Series Manual de usuario

MANUAL NO. TOBP C730600 40B
形式 AO-A3
取扱説明書
アナログモニタ
安川インバータ1000シリーズオプション
製品を安全にお使い頂くために,この取扱説明書を必ずお読みください。
また,本書をお手元に保管していただくとともに,最終的に本製品をご使用になる
ユーザー様のお手元に確実に届けられるよう,お取り計らい願います。
To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.
Installation Manual
Analog Monitor
YASKAWA AC Drive 1000-Series Option
Type AO-A3

2YAS KAWA ELE CT RI C TOBP C730600 40B 1000-Series Option AO-A3 Installation Manual
Copyright © 2008 YASKAWA ELECTRIC CORPORATION
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or
transmitted, in any form or by any means, mechanical, electronic, photocopying, recording, or otherwise,
without the prior written permission of Yaskawa. No patent liability is assumed with respect to the use of the
information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality
products, the information contained in this manual is subject to change without notice. Every precaution has
been taken in the preparation of this manual. Yaskawa assumes no responsibility for errors or omissions.
Neither is any liability assumed for damages resulting from the use of the information contained in this
publication.

YAS KAWA ELE CT RI C TOBP C730600 40B 1000-Series Option AO-A3 Installation Manual 3
Table of Contents
1 PREFACE AND SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 RECEIVING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4 OPTION COMPONENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5 INSTALLATION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . 10
6 RELATED PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7 TROUBLESHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

4 YASKAWA ELECTRIC TOBP C730600 40B 1000-Series Option AO-A3 Installation Manual
1 Preface and Safety
1 Preface and Safety
Yaskawa manufactures products used as components in a wide variety of industrial systems
and equipment. The selection and application of Yaskawa products remain the responsibility
of the equipment manufacturer or end user. Yaskawa accepts no responsibility for the way its
products are incorporated into the final system design. Under no circumstances should any
Yaskawa product be incorporated into any product or design as the exclusive or sole safety
control. Without exception, all controls should be designed to detect faults dynamically and
fail safely under all circumstances. All systems or equipment designed to incorporate a
product manufactured by Yaskawa must be supplied to the end user with appropriate
warnings and instructions as to the safe use and operation of that part. Any warnings
provided by Yaskawa must be promptly provided to the end user. Yaskawa offers an express
warranty only as to the quality of its products in conforming to standards and specifications
published in the Yaskawa manual. NO OTHER WARRANTY, EXPRESS OR IMPLIED, IS
OFFERED. Yaskawa assumes no liability for any personal injury, property damage, losses,
or claims arising from misapplication of its products.
◆Applicable Documentation
The following manuals are available for the option:
Analog Monitor AO-A3 Option
Yaskawa AC Drive
1000-Series Option
Analog Monitor AO-A3
Installation Manual
Manual No: TOBPC73060040
Read this manual first.
The installation manual is packaged with the
option and contains information required to install
the option and set up related drive parameters.
Yaskawa Drive
Yaskawa AC Drive
1000-Series
Quick Start Guide
The drive manuals cover basic installation,
wiring, operation procedures, functions,
troubleshooting, and maintenance information.
The manuals also include important information
about parameter settings and drive tuning.
Access these sites to obtain Yaskawa instruction
manuals:
U.S.: http://www.yaskawa.com
Europe: http://www.yaskawa.eu.com
Japan: http://www.e-mechatronics.com
For questions, contact your local Yaskawa sales
office or the nearest Yaskawa representative.
Yaskawa AC Drive
1000-Series
Technical Manual
AO-A3

1 Preface and Safety
YASKAWA ELECTRIC TOBP C730600 40B 1000-Series Option AO-A3 Installation Manual 5
◆Terms
◆Registered Trademarks
Trademarks are the property of their respective owners.
◆Supplemental Safety Information
Read and understand this manual before installing, operating, or servicing this option. Install
the option according to this manual and local codes.
The following conventions indicate safety messages in this manual. Failure to heed these
messages could cause fatal injury or damage products and related equipment and systems.
Note: Indicates supplemental information that is not related to safety messages
Drive: Yaskawa AC Drive 1000-Series
Option: Yaskawa AC Drive 1000-Series Option Analog Monitor AO-A3
DANGER
Indicates a hazardous situation, which, if not avoided, will result in death or serious
injury.
WARNING
Indicates a hazardous situation, which, if not avoided, could result in death or
serious injury.
CAUTION
Indicates a hazardous situation, which, if not avoided, could result in minor or
moderate injury.
NOTICE
Indicates an equipment damage message.

1 Preface and Safety
6YAS KAWA ELE CT RI C TOBP C730600 40B 1000-Series Option AO-A3 Installation Manual
■General Safety
General Precautions
• The diagrams in this book may include options and drives without covers or safety shields to
illustrate details. Be sure to reinstall covers or shields before operating any devices. Use the option
according to the instructions described in this manual.
• Any illustrations, photographs, or examples used in this manual are provided as examples only and
may not apply to all products to which this manual is applicable.
• The products and specifications described in this manual or the content and presentation of the
manual may be changed without notice to improve the product and/or the manual.
• When ordering new copies of the manual, contact a Yaskawa representative or the nearest Yaskawa
sales office and provide the manual number shown on the front cover.
DANGER
Heed the safety messages in this manual.
Failure to comply will result in death or serious injury.
The operating company is responsible for any injuries or equipment damage resulting
from failure to heed the warnings in this manual.
NOTICE
Do not modify the drive or option circuitry.
Failure to comply could result in damage to the drive or option and will void warranty.
Yaskawa is not responsible for any modification of the product made by the user. This
product must not be modified.
Do not expose the drive or option to halogen group disinfectants.
Failure to comply may cause damage to the electrical components in the drive or option.
Do not pack the drive in wooden materials that have been fumigated or sterilized.
Do not sterilize the entire package after the product is packed.

YASKAWA ELECTRIC TOBP C730600 40B 1000-Series Option AO-A3 Installation Manual 7
2 Product Overview
2 Product Overview
◆About This Product
The Analog Monitor Option AO-A3 allows the user to expand the number of available
analog outputs to monitor drive performance.
The option uses drive parameter settings and the output signal gain and bias to assign
functions to output terminals V1 and V2.
The option has two analog outputs, an 11-bit signed (1/2048) output resolution, and a
-10 to 10 Vdc non-isolated output voltage.
◆Applicable Models
The option can be used with the drive models in Table 1.
Table 1 Applicable Models
Drive Series Drive Model Number
A1000 All models
L1000A All models

8 YASKAWA ELECTRIC TOBP C730600 40B 1000-Series Option AO-A3 Installation Manual
3 Receiving
3 Receiving
Please perform the following tasks upon receiving the option:
• Inspect the option for damage. Contact the shipper immediately if the option appears
damaged upon receipt.
• Verify receipt of the correct model by checking the model number printed on the option
nameplate. (Refer to Figure 1 on page 9for more information)
• Contact your supplier if you have received the wrong model or the option does not
function properly.
◆Option Package Contents
◆Tools Required for Installation
• A Phillips screwdriver (M3 metric / #1, #2 U.S. standard size) is required to install the
option.
• A straight-edge screwdriver (blade depth: 0.4 mm, width: 2.5 mm) is required to wire the
option terminal block.
• A pair of diagonal cutting pliers.
• A small file or medium-grit sandpaper.
Note: Tools required to prepare option cables for wiring are not listed in this manual.
Description: Option Ground Wires Screws (M3) Installation Manual
–
Quantity: 1331
AO-A3
MANUAL

YASKAWA ELECTRIC TOBP C730600 40B 1000-Series Option AO-A3 Installation Manual 9
4 Option Components
4 Option Components
◆Analog Monitor AO-A3 Option
Figure 1
Figure 1 Analog Monitor AO-A3 Option Components
◆Terminal Block TB1
Refer to Table 4 on page 20 for details on TB1 terminal functions and signal levels.
A – Terminal Block TB1 D – Installation hole
B–Potentiometers
<1> E – Model number
C – Connector (CN5) F – Ground terminal and installation
hole <2>
<1> NOTICE: Do not adjust the potentiometers on the option. The potentiometers are factory set and may change the
voltage output characteristics and cause output signal inaccuracy if misadjusted.
<2> The ground wires provided in the option shipping package must be connected during installation.
AO-A3
Underside
F
E
C
D
A
B
V1 AC V2 AC FE

10 YASKAWA ELECTRIC TOBP C730600 40B 1000-Series Option AO-A3 Installation Manual
5 Installation Procedure
5 Installation Procedure
◆Section Safety
DANGER
Electric Shock Hazard
Do not connect or disconnect wiring while the power is on.
Failure to comply will result in death or serious injury.
Disconnect all power to the drive and wait at least the amount of time specified on the
drive front cover safety label. After all indicators are off, measure the DC bus voltage to
confirm safe level, and check for unsafe voltages. The internal capacitor remains charged
after the power supply is turned off.
WARNING
Electrical Shock Hazard
Do not remove the front covers of the drive while the power is on.
Failure to comply could result in death or serious injury.
The diagrams in this section may include options and drives without covers or safety
shields to show details. Be sure to reinstall covers or shields before operating any devices.
Use the option according to the instructions described in this manual.
Do not allow unqualified personnel to use equipment.
Failure to comply could result in death or serious injury.
Maintenance, inspection, and replacement of parts must be performed only by authorized
personnel familiar with installation, adjustment, and maintenance of this product.
Do not touch circuit boards while the power to the drive is on.
Failure to comply could result in death or serious injury.
Otros manuales para 1000 Series
7
Este manual sirve para los siguientes modelos
1
Tabla de contenidos