XTRONIC 9010-PRO Manual de usuario

X-TRONIC USA
X-Tronic®Model
9010-PRO
Desolder Station
Instructions


- 1 -
TABLE OF CONTENTS
Introduction
Package Contents..................................................2
Product Features ...................................................2
Product Specifications ...........................................3
Getting Started
User Interface ........................................................4
Product Set-Up ......................................................5
Safety Precautions.................................................5
Operating Guidelines .............................................6
Function Setting .....................................................7
Maintenance
Main Unit................................................................9
Desolder Gun.........................................................9
Nozzle Tip ............................................................10
Heating Element ..................................................10
Filter Tube Assembly............................................11
Warranty..................................................................12
Contact Information...............................................14

- 2 -
PACKAGE CONTENTS
1 - X-Tronic 9010-PRO Main Desoldering Suction Unit
1 - X-Tronic Desolder Gun (attached to main unit)
4 - Nozzle Tips (.08mm, 1.0mm, 1.2mm & 2.0mm)
6 - Vaccum Port Filters - black (1 installed)
3 - Fiber Filters - white (1 installed)
3 - Spring Filters (1 installed)
2 - Front Chamber Seal (1 installed)
2 - Outer Chamber Seal (1 installed)
9 - Nozzle Tip Cleaners (set)
1 - Suction Tube Cleaner
1 - Sponge
1 - Anti-Slip Heat Resistant Silicone Pad
PRODUCT FEATURES
• ESD Safe
• PID Technology (Magic Temperature Compensation Technology)
• Light Weight & Compact
• Centigrade to Fahrenheit Selectable Temperature Function
• Easy to Read LED Display
• Digital Temperature Correction/Calibration Function
• Built-in Sleep Mode
• Built-in Auto-Off

- 3 -
PRODUCT SPECIFICATIONS
Model XTR-9010-PRO
Power of Unit ≤ 80W
Power of Suction Gun 60W
Temperature Range 662°F~896°F / 350°C~480°C
Temperature Stability ±1°C (static)
Heating Element Voltage AC 26V ±10%
Desolering Pump Power 12W
Vacuum Suction 0.05MPa
Tip Impedance <2Ω
Dimensions 9.2 x 8.0 x 5.3 in / 234 x 202 x 134 mm
Weight 9.7 lbs / 4.4 kg
Length of Cord ≥ 47 in / 120cm
Working Environment 32°F ~ 104°F / 0°C ~ 40°C
Storage Environment -68°F ~ 176°F / -20°C ~ 80°C
Storage Humidity 35% - 45%

- 4 -
USER INTERFACE
Main Unit
1
8
7
65
4
3
2
1. Model Number
2. Temperature Display
3. Temperature Decrease Button
4. Vacuum Port
5. Desoldering Gun Port
6. Function Key
7. Power Switch
8. Temperature Increae Button
Desoldering Gun
1. Suction Tip
2. Heating Element Cover
3. Retaining Nut
4. Filter Chamber
5. Grip Assembly
6. Grip Assembly Release Button
7. Pressure Indicator
8. Gun Body
9. Vacuum Tube
10. Cord Assembly
11. Trigger

- 5 -
PRODUCT SET-UP
1. Unpack all of the contents of the X-Tronic 9050-PRO unit.
2. Inspect the unit and accessories for any damage. If damage
is detected, please contact X-Tronic immediately (see back of
manual for contact information).
3. Connect the vacuum tube from desoldering gun to vacuum port
on the front panel of the main unit.
4. Verify the filter chamber tube, spring filter, fiber filter, & vacuum
port filter are all installed.
5. Place the desolder gun in the holder.
6. Plug in the power cord to the back of the unit.
7. Plug the 3-Prong AC cord into a 110/120V grounded outlet to
prevent electric shock or injury.
8. The unit is now ready to be powered on with the switch located on
the front of the unit.
SAFETY PRECAUTIONS
Operating the X-Tronic 9010-PRO desoldering station incorrectly may
cause damage to the equipment or the operator. When using this
product, the following basic measures should be strictly followed to
avoid hazards of electric shock, bodily injury, or fire.
1. When powered on, the suction tip temperature can exceed
752°F(400°C) -
2. Do not use near flammable or explosive objects
3. This unit is to be used for desoldering purposes only
4. Turn off power to unit when not in use
5. Unplug unit from AC wall outlet if it will not be used for an
extended period
6. The proper three-wire grounded plug must always be used to
ensure proper operation
7. The units desoldering gun is delicate. Do not tap it against any
surface to remove residues
8. This unit may smoke when powered on for the first time. Powering
up in a well-ventilated area is recommended

- 6 -
OPERATING GUIDELINES
General Set-up & Use
1. Before turning on the unit, choose the nozzle that will be used and
install it on the gun. (see page 9 for how to change nozzles).
Note: All new nozzle tips have solder in the tip hole to prevent
oxidation during first use. Once the unit heats up, the solder
will melt and reveal the hole.
2. Ensure that the desolder gun is in the holder.
Note: The desolder gun needs to be in the holder EVERY TIME
the unit is started.This is a saftey feature and the unit will not work
correctly if this is not followed.
3. Ensure there are no obstructions or blockages in the desolder gun
and/or attachments.
4. Turn on the the switch on the front of the unit.
5. Set the desired temperature by pressing the Temperature
Increase or Decrease Button until the desired temperature
displays on the screen.
6. IMPORTANT: After the Desoldering Gun has reached its set
temperature, PLEASE ALLOW another 2 minutes to fully preheat
before using the desoldering gun. Failure to do so may cause
clogging.
7. When the desolder gun is in the holder and inactive for 1 minute
(the default setting or whatever the sleep timer is set at) the unit
will go to into “Sleep Mode” and cool down to 392°F / 200°C.
8. To activate the desolder gun after it has been in “Sleep Mode”
pull the trigger and then allow it to warm back up to the set
temperature.
9. After using the desoldering gun, place it back into the holder.
10. When finished using the unit, the power can be turned off.
Note: If the unit will not be used for more than 12 hours, the unit
should also be unplugged from the wall as a safety precaution.

- 7 -
FUNCTION SETTINGS
Setting Sleep Timer
1. Turn on the power switch.
2. Ensure the desoldering gun is in the holder.
3. Press the * button. The LCD will read “L01”. The “01” indicates the
current sleep time is set at 1 minute.
4. Press the increase/decrease button to set the desired sleep time.
It can be set anywhere from 1 minute to 99 minutes.
NOTE: If you select “00”, this will turn off the Sleep Timer
Option. If the Sleep Timer is turned off, the unit will NOT
go into Auto-Shut Off Mode.
IMPORTANT: This is a safety feature and turning it off is NOT
recommended. Keeping your desoldering gun at the set
temperature when not in use will negatively impact the heating
element life.
5. The unit will automatically save the setting and exit the function
menu after six seconds.
6. The Sleep Timer has now been set.
Setting Auto-Shut Off Timer
1. Turn on the power switch.
2. Ensure the desoldering gun is in the holder.
3. Press the * button twice. The LCD will read “P01”. The “01”
indicates that the auto-shut off time is set to 1 minute.
4. Press the increase/decrease button to set the desired shut off
time. It can be set anywhere from 1 minute to 30 minutes.
NOTE: If you select “00”, this will turn off the Auto-Shut Off
option. This is a safety feature and turning it off is NOT
recommended.
IMPORTANT: The Auto-Shut Off timer starts when Sleep Mode
activates and the unit starts to cool down.
5. The unit will automatically save the setting and exit the function
menu after six seconds.
6. The Auto-Shut Off timer has now been set.

- 8 -
Temperature Calibration Offset
1. Turn on the power switch.
2. Ensure the desoldering gun is in the holder.
3. Press the * button three times. The LCD will read “R00”. The “00”
indicates that the current calibration offset temperature is 0°.
4. Press the increase/decrease button to set the desired temperature
offset.
5. The unit will automatically save the setting and exit the function
menu after six seconds.
6. The Temperature calibration offset has now been set.
Temperature Conversion
1. Turn on the power switch.
2. Ensure the desoldering gun is in the holder.
3. Press the * button four times. The LCD will read “C”. This indiates
that the current temperature measurment is in °C.
4. Press the increase/decrease button to set the desired temperature
output mode.
5. The unit will automatically save the setting and exit the function
menu after six seconds.
6. The will now display the temperature in the desired unit of
measure.
Tabla de contenidos
Otros manuales de Herramientas eléctricas de XTRONIC
























