WorkPro BlueLine Digital Manual de usuario

User manual
English version
Rev. 141101

Contents
- Precautions........................................................................................................3
- General View......................................................................................................4
- Accessories........................................................................................................4
- Introduction........................................................................................................5
- Componentes del Sistema.................................................................................6
- BLM....................................................................................................................7
- BL PSU...............................................................................................................8
- BLS 2M...............................................................................................................9
- BLS 2..................................................................................................................14
- BLS 2Lite............................................................................................................17
- BLMP 1...............................................................................................................20
- BLR 2..................................................................................................................23
- BLR 2Lite............................................................................................................28
- BLR 2A...............................................................................................................31
- BLC1...................................................................................................................34
- OSC Protocol :....................................................................................................36
- OSC for working with properties.....................................................38
- Overview of the BlueLine protocol.................................................40
- packet types in BluLine protocol ...................................................42
- UDP & IP protocols configuration...................................................43
- BlieLine protocol packets ..............................................................44
- Basic notions about LAN networks.....................................................................46
- I .........................................................................48Basic notions about IP protocol

PRECAUTIONS
Do not spill water or another liquid over the unit.
Tu reduce the risk of electric shock or fire, do not expose this appliance to rain or moisture.
Turn off the unit immediately if you detect a malfunction. If you detect smoke or unusual
odor from the equipment, stop using and unplug it.
Do not open the unit. There are not items for the user control inside. Do not dismantle or
modify the unit void the warranty.
Never try to repair it. Repairs by unqualified persons may cause damage or malfunction
Contact with authorized service.
Keep dry the unit. This product is not waterproof and can malfunction if is exposed to high
levels of moisture. The internal oxidation can cause damage.
Do not hit it. This product may malfunction it it is subjected to strong shock and vibration.
Keep away from strong magnetic fields. Do not use or place the unit near equipments that
generate strong fields of electromagnetic radiation or magnetic fields. Heavy loads of these
fields as radio transmitters can interfere with the display or affect the internal circuitry of the
product.
Cleaning. Due to the residues of smoke or dust, to clean the outside of the unit is necessary.
Use a conventional glass cleaner an a soft cloth.
COPYRIGHT. None part of this user manual may be reproduced, transmitted, transcribed,
stored in any system or translated into any language in any form or medium without
permission.
USER MANUAL
3

General View
Accessories
In this chapter, you will find information about BlueLine features, control operation and
configuration.
BlueLine functions and configurations can be different, depending on the BlueLine model.
The following accessories are included in the BlueLine Digital:
1x Main supply cable: Use this main power cable included in order to feed the BlueLine Digital.
7x Individual covers: Use these pieces to cover the empty slots.
22x Screws: Use these screws to fix the individial covers in the empty slots.
USER MANUAL
4

Introduction
Features:
-Management of audio sources and output zones.
-Multiple codification types.
-GPIO control.
-Real-time monitorization of the system.
-Web Server configuration.
-OSC control.
-POE
In this chapter you will find information aboutBlueLine features and functions.
BlueLine Digital is a distributed audio system based on streaming over Ethernet. It is possible to
send several channels (+ control) via Ethernet and with a very low latency. It can be a simple
transmission point to point, or a complete multichannel system with control and management of
alarm.
The audio distribution is based in the transmission over IP network. It is an economic and efficient
concept, easy to install and design. Thanks to its Plug&play system, the intallers does not need
any type of technical knowledge about network.
The central system is IP, therefore, it is possible to monitorize the netweok in order to check if any
device in the systen does not work properly. It anything happens, an alarm message will be sent
automatically to the users in order to check the system.
BlueLine digital is also compatible with other public address system. It can be used to transport
several channel through the network. It is possible to connect several power amplifiers designed t
o 100V line installations. It is an opportunity to control low and high installations with an unique
audio system.
Thanks to the modular design of the system, the installer can adapt BlueLine according to the
requirements of each installation. It is very interestying due to is allows to take advantage of the
advance system without a price increment in the installation.
USER MANUAL
5

Elements of the sytem
En este capitulo encontrará información acerca de los diferentes elementos que
componen el sistema BlueLine Digital.
El sistema BlueLine Digital cuenta con cuatro clases de dispositivos:
Central System BLM Modular central unit of the BlueLine system
BL PSU Main supply unit of the central BlueLine system
Senders BLS 2M 1 stereo channel sender with GPIO for BLM
BLS 2 1 stereo channel sender for BLM
BLS 2 LITE 1 unbalanced stereo channel sender (external)
BLMP 1 MP3 player with FM radio tuner
Receivers BLR 2A 1 stereo channel receiver with amplifier
BLR 2 1 stereo channel receiver with GPIO
BLR 2 LITE 1 stereo channel receiver
Controllers BLC 1 Zone control for the receivers
WNC Zone control
Note: In some points of this manual, we speak about "Zone of devices", take
into account that these are "virtual zones" when you can manage the
device according to their type (Senders or Receivers). This point has
not make reference to "Audio zones".
USER MANUAL
6

BLM
ON It indicates that the unit is powered on
LINK Ii indicates that the BLM is connected to the LAN
ACT It indicates that the unit is receiving/sending data
The BLM is the central modular unit for BlueLine system. It can accomodate up to 11 single
modular units. The basic configuration of BLM is compossed by a main supply unit (BL PSU)
and a sender (BLS 2M). Once installed these elements, it is possible to install up to 7 extra
single units.
It 19" rack format with 3 HU, allows to make all the connection internally trough the built-in
switch. Each module is feed with 5V supplied for the BL PSU.
In the front side of the BLM are placed the LEDs state with the following functions:
USER MANUAL
7

BL PSU
ACT
LINK
BLPSU
BL PSU is the central main supply unit in the BluLine system, this unit is placed inside BLM
and it occupies 3 units. The connection to main power (220-230 V AC) is made through a
cable IEC type included. The IEC base socket has 1A fuse.
The LAN connection is made through a RJ 45 base socket and it has 2 LEDs of state.
It indicates that the unit is powered on
It indicates that the BL PSU is connected to the LAN
It indicates that the unit is receiving/sending data
In thecase of the main electric supply fall down, BL PSU has an auxiliar 18-36 V DC input
USER MANUAL
8

BLS 2M
BLS 2M
AUDIO IP STREAMER
BLS 2M
AUDIO IP STREAMER
ACT
REAR
FRONT
It indicates that the unit is receiving/sending data
BLS 2M is a 1 stereo channel audio sender. This unit is placed in the BLM and it occupies one
single slot and it is feed insternally trough the 5V DC connectors.
The LAN connection is made through the connectin between the unit with the inner switch using
a RJ 45 cable. Thanks to the frontal audio source selector, it is possible to select quickly from 1
to 16 emmision channel.
In the front side you can find a LED indicating the state of the device:
The connection of audio inputs and alarm is made through terminals.
NOTE: One BlueLine installation MUST only have one BLS 2M
USER MANUAL
9

GPI port
5V power supply
RJ 45 Ethernet port
Balanced audio input (IN-B)
Balanced audio input (IN-A)
1 to 16 channel selection
Activity indicator
Alarm connection
GPO port
BLS 2M incorporates 4 GPI ports and 4 GPO ports which state is reflected in the GPIO ports of
the BLR devices. If you clese the GPI 2 in the BLS 2M, the unit will send the state al GPO 2 in
all BLR and vice versa. Take into account that when you close one GPI in the BLS 2 M, its state
will appears in all BLR with GPIO, although they are in different channels.
When you act over the GPI 1 in the BLS 2M, all the device in the zone 2 (by default, we considerer
them paging zone or receiver zone) to “listen” in the channel “0" with maximum volume. This will
act the paging function which made the following functions:
1. The unit sends a "push*" message which includes the state of the device.
2. It sends the command "source=0"
3. It sends the command "Mode=Single"
4. It sends the Master, Channel1 and channel 2 volume to 0 dB
When the GPI 1 is disactivated, it sends a "pop*" message which loads the configuration previous
to "push" message.
By default the BlueLine system is configured in two zones:
Zone 1: For senders
Zone 2: For receivers
push*: Command usedf to read the state of a device and to store its configuration
pop*: Command used to load the stored configuration through a push command
USER MANUAL
10
Otros manuales para BlueLine Digital
1
Tabla de contenidos
Otros manuales de Sistema estéreo de WorkPro