wiking Mini 2 Manual de usuario

01.11.2020 / 53-077-2
Installation- and User’s Manual
made by
EN
WIKING Mini 2

Contents
Drawings ............................................................................................................3-6
Installation ............................................................................................................. 8
Firing manual - wood........................................................................................... 13
Firing in general .................................................................................................. 16
Maintenance........................................................................................................ 17
Declaration of Performance ................................................................................ 19
Product informaiton EcoDesign .......................................................................... 20
Trouble Shooting ................................................................................................. 22
......................................................................................... 24

Page 3 of 24 pages
A
B

Page 4 of 24 pages
C
D1

Page 5 of 24 pages
D3
D2

Page 6 of 24 pages
2
1
E

Page 7 of 24 pages
.

Page 8 of 24 pages
In general
Congratulations on your new WIKING woodburning stove. We are pleased that you have cho-
optimum operation and safety, we recommend that the installation should be carried out by an
retailers, visit www.wiking.com under “Retailer locations”.
Safety
The installation of your WIKING woodburning stove must always comply with all European,
national and local building regulations. The installation must be carried out in accordance with
the instructions in the installation and user manuals and subsequently registered with the local
authorities. Upon installation, the chimney sweep must approve the installation before you can
start using the woodburning stove. All WIKING woodburning stove packaging material must be
handled in accordance with local waste management regulations.
Room requirements
Always ensure a supply of fresh combustion air to the room where the stove is to be installed.
The woodburning stove uses approx. 7-16 m3 of air per hour. A window that can be opened
valve/grate. In newly built/airtight dwellings, we recommend that a fresh air system should be
installed for the direct supply of external air to the combustion. This fresh-air system may be
bought separately.
withstand the weight of the stove and the chimney. The weight of the chimney should be cal-
culated according to its dimensions and height.
Technical measures and data
Test results from nominal test EN 13240
4.5 kW
Flue gas temperature EN 13240 measurement point 236ºC
Flue gas temperature measured in the outlet socket 283ºC
3.6 g/s
83 %
73 %
PM 6 mg/m3
OGC 84 mg/m3
NO299 mg/m3
CO at 13% O2881 mg/m3
CO at 13% O20.0705 %
110
A+
Test result based on NS 3058
Particle emissions 1.86 g/kg

Page 9 of 24 pages
Norsk
Model Weight Height Width Dept
Mini 2 with base 72.1 kg 60.8 cm 46.8 cm 35.6 cm
Mini 2 with low legs 72.0 kg 65.2 cm 46.8 cm 35.6 cm
Mini 2 with high legs 73.5 kg 68.4 cm 51.3 cm 37.1 c m
Floor plate
European, national and local regulations must be observed in terms of the size and thickness
your WIKING retailer for assistance. The combustion chamber opening is 35.0 cm wide.
Distance to combustible materials
Min. distances
- uninsulated ue gas pipe:
WIKING Mini 2
with base
WIKING Mini 2
with low legs
WIKING Mini 2
with high legs
- insulated ue gas pipe:10 cm 10 cm 10 cm
Recommended for brick wall, side 10 cm 10 cm 10 cm
For combustible wall, back 12.5 cm 12.5 cm 12.5 cm
For combustible wall, side 32.5 cm 32.5 cm 32.5 cm
To combustible wall,
corner installation, 45º
7.5 cm 7.5 cm 7.5 cm
stove
22* cm 22* cm 22* cm
Distance to furnishings in front 100 cm 100 cm 100 cm
* This distance requirement is met if the stove is installed with high legs or on a wall with the required distance below the wood-burning stove
Min. distances
- insulated ue gas pipe:
WIKING Mini 2
with base
WIKING Mini 2
with low legs
WIKING Mini 2
with high legs
Recommended for brick wall, back 10 cm 10 cm 10 cm
Recommended for brick wall, side 10 cm 10 cm 10 cm
For combustible wall, back 7.5 cm 7.5 cm 7.5 cm
For combustible wall, side 32.5 cm 32.5 cm 32.5 cm
To combustible wall,
corner installation, 45º
5 cm 5 cm 5 cm
stove
22* cm 22* cm 22* cm
Distance to furnishings in front 100 cm 100 cm 100 cm
* This distance requirement is met if the stove is installed with high legs or on a wall with the required distance below the wood-burning stove
IMPO RTANT:
Combustible materials may not be placed under the stove.
WIKING Mini with a base and WIKING Mini with short legs must not be mounted on
combustible oors. It is still considered a combustible oor even if an ember catching,
non-combustible oor plate is placed on top of the combustible oor.
A non-combustible structure under WIKING Mini with a base and low legs must extend
at least 400 mm in front of the stove.

Page 10 of 24 pages
Remember to pay attention to the applicable regulations concerning the required distance
between the wall and smoke pipe.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should
sometimes be treated as a combustible wall, in which case we ask you to contact your local
chimney sweep or glass producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
As a general rule, satisfactory draught conditions are achieved if the chimney is 4 m above
the stove and at least 80 cm above the ridge. If the chimney is placed at side walls, the top of
the chimney should always be higher than the ridge or the tallest point of the roof. Always be
aware of any national and/or local regulations applying to thatched roofs and the location of
the chimneys.r.
-
18-20 Pa.
The chimney must have a minimum clearing of Ø 125 mm or Ø 150 mm. The chimney must be
-
cordance with the brand label. Ask your WIKING retailer for further information.
Changing the Smoke Outlet from Top Outlet to Back Outlet
Proceed as follows to change the smoke outlet from top outlet to rear outlet:
5. Install the cover plate on top of the stove with the three screws.
6. Place the smoke ring in the smoke outlet hole in the back of the stove and secure it with the
three screws.
7. Replace the top plate on the stove.
A top cover can be bought as an accessory to cover the hole in the top plate of the stove if the
stove is connected to a rear smoke outlet.
A top cover can be bought as an accessory to cover the hole in the top plate of the stove
if the stove is connected to a back smoke outlet.
Connection to chimney
All the stoves have both back and top smoke outlet that can be connected to an approved steel
chimney on top or directly out at the rear to a chimney.
Make sure that the chimney is tight and that no false draft is caused around neither the cover
plate, in connection with a covered smoke outlet, nor the cleanout door and pipe connections.
Otros manuales para Mini 2