White Mountain LSU18SF-2 Guía de inicio rápido

INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
LOG SET FOR
VENTED AND UNVENTED
MULTI-SIDED GAS LOG HEATER
MODELS
LSU18SF-2
LSU24SF-2
LSU30SF-2
WARNING: If not installed, operated and main-
tained in accordance with the manufacturer's
instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
Log sets comply with ANSI Z21.11.2 Unvented
Heaters and also comply with ANSI Z21.60
Decorative Vented Appliances for Solid Fuel
Burning Fireplaces. State or local codes may
only allow operation of log sets in a vented
conguration. Check your state or local codes.
WARNINGS
– Do not store or use gasoline or other
flammable
vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier
from neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the re department.
– Installation and service must be per-
formed by a qualied installer, service
agency or the gas supplier.
If the information in this manual is not fol-
lowed exactly, a re or explosion may result
causing property damage, personal injury
or loss of life.
The White Mountain Log Collection:
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for future
reference.
LSU24SF-2 Shown
STONE RIVER
Page 1

25743-1-1015
Page
2
Section Page
Important Installation Guidelines .....................................................................3
General Information .........................................................................................3
Requirements for Canada................................................................................4
LSU18SF-2 Log Identication..........................................................................5
LSU18SF-2 Log Placement ....................................................................... 6-12
LSU(24,30)SF-2 Log Identication.................................................................13
LSU(24,30)SF-2 Log Placement...............................................................14-21
Ember Placement LSU18SF-2 Photos ..........................................................22
Ember Placement LSU24SF-2 Photos ..........................................................23
Ember Placement LSU30SF-2 Photos ..........................................................24
Parts List and Parts View...............................................................................25
Master Parts Distributor List...........................................................................26
How to Order Repair Parts ............................................................................26
Service Notes.................................................................................................27
TABLE OF CONTENTS

25743-1-1015 Page 3
Proper Log Placement
Log placement is critical to proper burner performance. Logs must
be correctly positioned onto the burner. The photos in this manual
show the proper pinned position for logs on this set. Owners need to
be shown proper log placement and instructed not to move the logs.
Logs must t rmly onto the burner when positioned as shown in
the photos. Malformed logs or logs with sloppy pin holes must be
replaced.
Proper Placement of Rock Wool and Decorative Lava Rock
Rock wool can be added to burners for a glowing ember effect.
It must be positioned only on the front portion of the burner. The
photos in this manual show the proper placement of rock wool.
Decorative lava rock or small wood pieces should never be placed
on the burner. These items are only for placement on the oor of
the replace or rebox.
Proper Primary Airow into Burner
For proper burner operation and ame appearance, the ow of
primary air into the venturi tube, located on the rear of the burner,
must not be reduced. This ow of air is reduced if dirt, lint or other
obstructions build-up around or inside the venturi. Any obstruction
in the venturi tube area must be removed. The ow of air into the
venturi is also reduced if the gas orice isn’t centered in the venturi
inlet and/or is not aligned with the venturi. Any misalignment of the
burner orice may be corrected by bending the shutter cap holding
the orice to the inlet of the venturi tube.
Ceiling Fans, Portable Fans or Logs Installed Near Cold Air
Returns
Ceiling fans or oscillating oor type fans need to be monitored
during the operation of vent-free logs. If the air blows directly into
the ame causing it to impinge on the log set, or rebox, it should be
turned off or redirected. Ceiling fans could be reversed to possibly
eliminate ame impingement, and the oor fan could be redirected.
Upon installation, be aware of any cold air returns or vents in the
proximity of the log set. Any draft created around a vent-free log
set can cause the ame to impinge on the log and create a sooting
situation.
Candles
Avoid the use of scented or decorative candles while the log set is
in operation. Candles produce a residue in the air that creates a
soot like substance. Burning candles while the log set is operating
magnies the problem. It should be noted that candles, in general,
produce soot. The amount of time burned and the quantity of candles
burned will determine the amount of soot produced and deposited.
Make Owners Aware of Proper Log Set Operation
Properly installed and properly maintained log sets do not deposit
soot on the logs. If users see soot appear on a log, call for service.
Do not continue to operate the log set.
Sunken Fireplace
If installing this unit into a sunken replace, you must raise the
oor to insure adequate airow and guard against sooting. Raise
replace oor using a non-combustible material, which is secure.
Glass Doors
Make sure that glass doors are open during all operations of the log
set. The opening of the glass door frame should be the dimension
used for the minimum front opening of the rebox.
Woodburning Fireplaces
The interior of the rebox and the chimney should be cleaned and
free of all creosote before installing a gas burning log set. Creosote
will soften when heated and can drop on the log set causing odors
and possibly sooting.
IMPORTANT INSTALLATION GUIDELINES
Qualied Installing Agency
Installation and replacement of gas piping, gas utilization equip-
ment or accessories and repair and servicing of equipment shall be
performed only by a qualied agency. The term "qualied agency"
means any individual, rm, corporation, or company that either in
person or through a representative is engaged in and is responsible
for (a) the installation, testing, or replacement of gas piping or (b) the
connection, installation, testing, repair, or servicing of equipment;
that is experienced in such work; that is familiar with all precautions
required, and that has complied with all the requirements of the
authority having jurisdiction.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA54* or International Fuel Gas Code.
*Available from the American National Standards Institute, Inc. 11
West 42nd St., New York, N.Y. 10018.
State of Massachusetts: The installation must be made by
a licensed plumber or gas tter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural gas-red supplemen-
tal room heaters shall provide to each purchaser a copy of
527 CMR 30 upon sale of the unit.
In the State of Massachusetts, unvented propane and natural
gas-red space heaters shall be prohibited in bedrooms and
bathrooms.
GENERAL INFORMATION
WARNING
Do not allow fans to blow directly into the replace. Avoid
any drafts that alter burner ame patterns.
WARNING
Do not use a blower insert, heat exchanger insert or other
accessory not approved for use with this heater.
WARNING
Before installing in a solid-fuel burning replace, the chimney
ue and rebox must be cleaned of soot, creosote, ashes
and loose paint by a qualied chimney cleaner.

25743-1-1015
Page
4
REQUIREMENTS FOR CANADA
This unit cannot be installed in a UNVENTED application, this
unit can only be installed as a VENTED application with these
requirements.
IMPORTANT SAFETY INFORMATION
This unit complies with ANSI Z21.60and CGA 2.26 Decorative
Gas Appliances For Installation In Solid Fuel Burning Fireplaces.
Do not burn wood or solid fuels in a replace where a decorative
gas log set is installed. This appliance is for installation only in
a solid fuel burning replace, masonry replace or manufactured
replace.
1. Please follow all local codes regarding installation, combus-
tion and ventilation air or in the absence of local codes follow
the National Fuel Gas Code ANSI Z223.1(U.S. installation), or
CAN/CGA-B149, Installation Code (Canada installation).
2. Proper installation, burner pan location and log placement is
important to achieve optimum look and performance of your
gas log set. The logs have been designed for easy location
and placement on the grate and must be followed for proper
operation.
3. Do not operate this log set with glass doors in the closed po-
sition. A replace screen must be in place when the log set
is burning. Adequate combustion air must be provided for
proper venting. All ames should go up and out the top of the
rebox into the ue vent. If any ames oat or curl forward
into the room do not operate appliance. Check for an open
ue and adequate combustion air into the room. A damper
clamp must be installed on the rebox damper to maintain an
open ue vent condition. Refer to replace owners manual
INSTALLING DAMPER CLAMP section.
4. Young children must be carefully supervised when they are in
the same room as the gas log while in operation. Do not place
stockings, clothing or any ammable material above or near
the replace.
5. Do not substitute or use materials other than those supplied
for use with the log set.
6. Also refer to IMPORTANT SAFETY INFORMATION in the
replace Owner's Manual.
• Clothing or other ammable material should not be placed on
or near the appliance.
• Do not place trash or other articles on the log set during op-
eration.
• During manufacturing, fabricating and shipping, various com-
ponents of this appliance are treated with certain oils, lms or
bonding agents. These bonding agents are not harmful but
may produce annoying smoke and smells as they are burned
off during initial operation of the appliance. This is a normal
temporary occurrence. A window should be opened during the
initial bake out period.
• Keep burner and control compartment clean.
• Installation and repair should be done by a qualied service
person. The appliance should be inspected before use and
at least annually by a qualied service person. More frequent
cleaning may be required due to excessive lint from carpeting,
bedding materials, etc. It is imperative that control compart-
ments, burners and circulating air passageways of the appli-
ance be kept clean.
• Do not put anything around the replace that will obstruct the
ow of ventilation air.
• Do keep the appliance area clear and free from combustible
material, gasoline and other ammable vapors and liquids.
• A yearly examination and cleaning of the venting system of
the solid-fuel burning replace must be performed by a quali-
ed agency.
• Do make a periodic visual check of pilot and burners. Clean
and replace damaged parts.
• Do not use this appliance if any part has been under water.
Immediately call a qualied service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
• Never burn solid fuels in replace where a gas log set is in-
stalled.
• This unit complies with ANSI Z21.60 Decorative Vented Appli-
ances for Solid Fuel Burning Fireplaces. State or local codes
may only allow operation of this appliance in a vented congu-
ration. Check your state or local codes.
WARNING
Any modication to this gas log set or to controls can be
dangerous. Improper installation or use of the gas log set
can cause serious injury or death from re, burns, explo-
sion or carbon monoxide poisoning.
WARNING
DO NOT OPERATE THIS GAS LOG SET WITH GLASS
DOORS CLOSED
WARNING
Before installing in a solid fuel burning replace, the chim-
ney ue and rebox must be cleaned of soot, creosote,
ashes and loose paint by a qualied chimner cleaner

25743-1-1015 Page 5
LSU18SF-2 LOG IDENTIFICATION
Log
Description
Part
Number Front View Top View
Log A R9297
Log B R9298
Log C R9299
Log D R9300
Log E R9301

25743-1-1015
Page
6
Before you begin: Do not, handle these logs with your bare
hands! Always wear gloves to prevent skin irritation. After
handling logs, wash your hands gently with soap and water.
All Logs
The positioning of the logs is critical to the safe and clean
operation of this heater. Sooting and other problems may
result if the logs are not properly and rmly positioned in the
appliance.
Refer to Figures 1 for the following warning.
The following WARNING applies when log set is installed
onto an unvented gas burner assembly.
PROPER INSTALLATION SEQUENCE
ATTENTION: For the instructions below, "Front" indicates the
side of the burner with the valve. For step by step instructions
with images see page 7-12.
1. Place Log A onto the two left front burner pins and two
left middle row burner pins.
2. Place Log B onto the two right front burner pins.
3. Place Log C onto the two right middle row burner pins.
4. Place Log D onto the two left rear burner pins.
5. Place Log E onto the two right rear burner pins.
Note: A single layer of embers is to be used when applying
Platinum Bright Embers (alone or in combination with
production embers) to the burner.
LSU18SF-2 LOG PLACEMENT
4
1
2
3
5
Replacement Loose Material
(glowing embers)
Part Number
Platinum Bright Embers PE-20-1
Rock Wool 15999
WARNING
Failure to position the parts in accordance with this
diagram or failure to use only parts specically approved
with this appliance may result in property damage or
personal injury.
WARNING
This appliance is equipped for natural or propane
gas. Field conversion is not permitted.
Log Placement LSU18SF-2
Figure 1
NOTE: When placed correctly, the logs will not cover any
ports. See Figures 1 Ember Placement Photos, page 22.

25743-1-1015 Page 7
1. Place Log A onto the two left front burner pins and two left middle row burner pins. See image below.
LSU18SF-2 LOG PLACEMENT

25743-1-1015
Page
8
2. Place Log B onto the two right front burner pins as shown below.
LSU18SF-2 LOG PLACEMENT

25743-1-1015 Page 9
3. Place Log C onto the two right middle row burner pins as shown below.
LSU18SF-2 LOG PLACEMENT

25743-1-1015
Page
10
4. Place Log D onto the two left rear burner pins. See image below.
LSU18SF-2 LOG PLACEMENT
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Calentador de gas de White Mountain
Manuales populares de Calentador de gas de otras marcas

Superior
Superior BGE18NV Manual de usuario

Dru
Dru Room-sealed atmospheric gas-fired heating... Manual de usuario

klover
klover TKR 35 Manual de usuario

Rothenberger Industrial
Rothenberger Industrial 035984 Manual de usuario

New Buck Corporation
New Buck Corporation 34 Manual de usuario

Hargrove
Hargrove Timberland Glow Guía de inicio rápido