Western Digital OpenFlex F3100 Manual de usuario

Installation
Guide
OpenFlex F3100 and E3000
1ET2047
Version 1.0
October 2019

Installation Guide Points of Contact
Points of Contact
For further assistance with a Western Digital product, contact Wester Digital Datacenter Platforms technical
support. Please be prepared to provide the following information: part number (P/N), serial number (S/N),
product name and/or model number, and a brief description of the issue.
Email:
support@wdc.com
Website:
https://portal.wdc.com/Support/s/
i

Installation Guide Table of Contents
Table of Contents
Points of Contact....................................................................................................................................i
Chapter 1. Installation......................................................................................................1
Installation Equipment Requirements................................................................................................. 2
Installation Safety................................................................................................................................. 2
Before You Begin................................................................................................................................. 3
DHCP..............................................................................................................................................4
How to Report Damage.............................................................................................................. 4
Installation Procedure.......................................................................................................................... 6
Accessing Storage............................................................................................................................. 23
Chapter 2. Safety............................................................................................................31
Electrostatic Discharge......................................................................................................................32
Optimizing Location...........................................................................................................................32
Power Connections............................................................................................................................32
Power Cords.......................................................................................................................................32
Rackmountable Systems....................................................................................................................33
Restricted Access Location...............................................................................................................33
Safety and Service............................................................................................................................. 33
Safety Warnings and Cautions..........................................................................................................34
ii

Installation Guide 1. Installation
1.1 Installation Equipment Requirements
1.1 Installation Equipment Requirements
This section lists everything that must be in place or available to perform the installation. This includes the
equipment and components that are included in the packaging.
Table 1: Equipment and Components Included
Category Item # Included
E3000 Chassis w/ PSUs,
Fans, and BMC Pre-installed
1
Rack-mounting Rails
w/ mounting hardware
1 set of 2
F3100 1 - 10 depending on configuration
Components
Device Blanks 0 - 9 depending on configuration
M5 x 12mm T15 Torx Pan
Head screws w/ washers
6Screws
M5 x 10mm T15 Torx Flat
Head screws w/ washers
6
Cables 3m, C14 - C15 Power Cables 2
Table 2: Additional Equipment Needed
Equipment Required or Recommended?
T15 Torx Screwdriver Required
T15 Torx Screwdriver w/ Torque Measuring
Capability
Recommended
Level Recommended
Lift Equipment Recommended
ESD Mitigation Equipment (site specific) Required
Table 3: Torque Specifications for Screws
Screw Type Torque Value
M5 x 12mm T15 Torx screws w/
washers
3.38-3.61 Nm / 30-32 in-lbf
M5 x 10mm T15 Torx screws 3.38-3.61 Nm / 30-32 in-lbf
1.2 Installation Safety
2

Installation Guide 1. Installation
1.3 Before You Begin
Safety is the number one priority for personnel responsible for installing the OpenFlex F3100 and E3000
platform. This section outlines what to consider before performing an installation.
Protect Yourself and Others
Before any installation of an OpenFlex F3100 and E3000 it is important to take steps to keep all personnel
performing the installation (or individuals near the installation site safe). Make sure all paths and floors are
clean and free of obstacles. Do not wear clothing that is loose or can become tangled or catch on anything,
or clothing that is too tight and may restrict movement. Read all safety labels and instructions in this manual
and on the equipment being used for installation. Never lift the E3000 alone. It should always be teamlifted.
When installing the unit in a rack, it is highly recommended that you install it at the lowest possible U height
of the rack. This is intended to prevent an imbalanced load and it keeps the center of gravity low on the rack
to help prevent tipping hazards.
Protect Your Equipment
Always use the proper tooling outlined in this document during installation. This includes torque
specifications and driver heads when installing screws, lifting equipment, and safety equipment, as well
as the E3000 and F3100s themselves. Always respect the ESD requirements outlined at your site. Use
ESD mitigation and prevention equipment to prevent discharges that may damage equipment. During
installation, do not tip the enclosure.
The following is a list of safety equipment that should be considered before proceeding:
•Safety Shoes/Steel-toed Boots (ESD Safe is a plus)
•Lifting equipment
•ESD mitigation equipment
•Safety vests and hard hats
•Rack support or anchoring equipment
Warning: Never lift the chassis by the handles on the rear fan modules! They are not intended
to support the weight of the unit. Injury or damage to the unit is likely.
1.3 Before You Begin
3

Installation Guide 1. Installation
1.3 Before You Begin
The installation process for the OpenFlex F3100 and E3000 happens in four basic phases: Unpacking,
Chassis Installation, Device Installation, and Initial Bringup. The following procedure outlines the steps for
Chassis and Device Installation in a rack.
1.3.1 DHCP
When the E3000 BMC module is powered on, it will try to establish an IP address using DHCP. The E3000
and F3100 require access to a DHCP Server to access the OCGUI. Access to a DHCP server should be
setup ahead of time to ensure the installation of the product is not gated. If a DHCP server is not present
on the network that the E3000 is connected to, access to the BMC and the OCGUI will not be available.
1.3.2 How to Report Damage
During the installation process, there are a number of inspection steps where the installation team should
be looking for damage to the product that may have occurred during shipment. If damage is found,
document the items using the following process.
Step 1 : Take two digital photos of the damaged packaging or component, one closeup shot showing
the damage in detail and one further out so the support engineers working the case can see
where the damage occurred.
Step 2 : Open a web browser and go to https://portal.wdc.com/Support/s/login/.
The Western Digital Enterprise Support Center page will appear:
Step 3 : Log in to your Support Portal account using an email address and password:
4

Installation Guide 1. Installation
1.3 Before You Begin
The Western Digital Enterprise Support Center page will appear, providing various support-
related options:
Step 4 : Click the Cases icon:
The Case Detail page will appear:
5

Installation Guide 1. Installation
1.4 Installation Procedure
Step 5 : At a minimum, select a Case Reason, Brand, and Severity from the available drop-down menus,
and provide a brief explanation of the issue in the Summary field; these fields are required.
Step 6 : In addition, type the Part Number and Serial Number into the appropriate fields, and select the
Product Category and Product Sub-Category that match your Product Name / Model Number.
Tip: For instructions on filling out the remaining fields, refer to the Enterprise
Support Center User Guide, available through a the link on the Enterprise
Support Center page:
Step 7 : Click the Submit button:
1.4 Installation Procedure
6

Installation Guide 1. Installation
1.4 Installation Procedure
Step 1 : Remove the plastic retention bands with a box cutter and remove the top cap by lifting it off
and away from the pallet using the cutouts on the sides of the carton. This step may require two
people to finish.
Figure 6: Unband and Remove Top Cap
Step 2 : Verify that the top tray contains all of the accessories. This should include all rails, screws,
washers, and cables. Reference the packaging contents list in Table 1: Equipment and
Components Included (page 2) for details.
Step 3 : Remove the rails from the rail kit box.
a. Remove the rail kit box from the Accessory Tray located directly under the packaging cap.
b. Open the rail kit box and remove the top protective materials.
c. Lift the rails out of the box and inspect them for damage.
7
Otros manuales para OpenFlex F3100
1
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Servidor de Western Digital

Western Digital
Western Digital HGST Ultrastar Serv24-HA Manual de usuario

Western Digital
Western Digital Ultrastar Data60 Manual de usuario

Western Digital
Western Digital EcoDesign Disclosures Ultrastar Edge Manual de usuario

Western Digital
Western Digital ActiveScale X100 Instrucciones de instalación

Western Digital
Western Digital Ultrastar Serv60+8 Manual de usuario

Western Digital
Western Digital Sentinel DS5100 Manual de funcionamiento