Wealtec ELITE 200 Manual de usuario

Wealtec Corp.
ELITE 200
POWER SUPPLY
Service & Operation & Instruction
Manual
Version 2.0
Item # 0 2012
http://www.wealtec.com
E-mail : [email protected]

Packing List
x 1 main body
x 1 power cable
x 1 manual
x 1 warranty card
Wealtec Corp.
1885 Meadowvale Way, Sparks, NV 89 31, USA TEL: +1-775-351-2066 FAX: +1-775-351-2077

Index
A. Important Notice -------------------------------------------------------------------------------------------- 2
A-1. Warranty
A-2. Technical and Service Contact
A-3. Safety Notice
A-3-1. Certification
A-3-2. Safety Information
B. Introduction -------------------------------------------------------------------------------------------------- 5
B-1. Specifications
B-2. Product Descriptions
C. Installations -------------------------------------------------------------------------------------------------- 9
. Operation Instructions ------------------------------------------------------------------------------------ 9
E. Maintenance ------------------------------------------------------------------------------------------------ 11
F. Trouble shooting -------------------------------------------------------------------------------------------- 12
F-1. Instrument Service
F-2. General Error
F-3. Error Message
G. Order Information ------------------------------------------------------------------------------------------ 16
Appendix: Service Manual ---------------------------------------------------------------------------------- 17
Section 1 ─ Product Description
Section 2 ─ ELITE 200 Function Description
Section 3 ─ Service Parts List
Section ─ Circuit Diagram
1

A. Important Notice
The instrument is designed for laboratory use only.
Before setting up and operating ELITE 200 power supply, please carefully read these
instructions to get familiarized with installation and operation process. Instructions should be read by
well-trained individuals or by technical people from Wealtec Corp. before operating the instruments.
Any improper usage of the instruments may cause damage, please refer to the safety notice.
The instruments shall not be modified or altered in any way. Any modification or alteration will
void the warranty, void the regulatory certifications and create potential safety hazard. Wealtec is not
responsible for any injury or damage caused by using the instruments for any non-intended purpose or
by modifying the instruments by any person who is not authorized by Wealtec Corp.
A-1. Warranty
ELITE 200 power supply, is warranted to be free from defects in materials or workmanship for a
period of one year from the original invoice date, under normal usage. Any defects occurring during
warranty period, Wealtec Corp. will repair or replace defective products or parts without charge unless
the defects arising from below conditions. The defects described below are specially excluded from
Wealtec warranty policy.
1. Improper operation of the instrument.
2. Repair or modification by any person who is not authorized by Wealtec Corp.
3. Damage caused by any (in)-direct accident, neglect or misuse.
2

. Damage caused by disaster.
5. Damage caused by any improper solvents or samples
A-2. Technical and Service Contact
Most of the operation details are described in the instruction manual and operator can find
appropriate solutions according to these instructions. For any other technical/ service questions,
please contact your local representative or contact Wealtec international technical/ service specialist by
E-mail: [email protected].
A-3. Safety Notice
A-3-1. Certification
ELITE 200 power supply, is designed to meet the international electrical safety standards
EN61010 and EMC regulations. This product holds CE marking and operation is according to the
guidance of its instruction manual certificated safe. Any modification or alteration will void the warranty,
void the regulatory certifications and create potential safety hazard.
3

A-3-2. Safety Information
Basic safety precautions must be observed when operating the centrifuge in order to avoid
hazards of electrical shock or possible physical injuries.
ELITE 200 power supply, is not to be used in Class 1, Division 1, Group C hazardous location defined
by the National Fire Protection Association, Bulletin No.56A (Inhalation Anesthetics), as extending
upward to a level of 5 feet above the floor where flammable anesthetics are used.
CAUTION:
Below information should be read before using ELITE 200 power supply to prevent possible injury.
To Avoid Electrical Shock:
Plug the power cord only into a grounded 3-wire receptacle.
Do not remove the grounding prong from the power plug.
Always unplug the power code before attempting to service the ELITE 200 power supply.
To Avoid amage to the Instrument:
Operate the ELITE 200 power supply with the space at least 6cm around the unit.
Do not operate ELITE 200 power supply in the environment of high humidity (≥95%).
When taking out ELITE 200 power supply from cold room, the condensation can short its
internal electrical circuit. Do not operate the unit until it equilibrates to room temperature for 2
hours.
4

B. Introduction
ELITE 200 power supply is a settable power supplies with excellent quality. It is perfect for
submerged horizontal, mini vertical gel electrophoresis and electro-blotting applications. The output
of ELITE 200 power supply is controlled by timer and constant current/voltage, -set of apparatus can
be connected to each power supply simultaneously for experiment convenience and its compact, light
and stackable design offers space saving as well.
5

B-1. Specifications
Outputs: voltage 5-200VDC adjustable in 1V steps
current 0.01-2.00ADC adjustable in 0.01A step
power 200W max.
Input power 120/230, 50-60Hz
Output terminals set in parallel
Timer control 1-999 minutes
Display 3 digit 7 seg LED
Panel control Touch panel
Status alarm Yes
Operation temperature 0- 0℃
Operation Humidity 10% to 90% R.H. Non-condensing
Noise level 32dB
Regulation: Ripple ±0.3%@200V and 200W
Line regulation ±0.3%@200V and 200W from 90-132VAC or
198-26 VAC
Load Regulation
±0.5%@200V for a 50% change in output load
Drift ±0.3% after 30min warm up @ 200V and 200W
Weight 2.6kg
Dimensions (LxWxH) 13x8.7x2.9inches
6

B-2. Product escriptions
The front and rear panel keys are used to set up and run the ELITE 200 power supply. A beep sound
will alarm to inform user when front panel key been pressed. A long beep sound will alarm after the run
is complete or if an error occurs. This beep sound will continue to alarm every ten seconds until any
key is pressed or the power is turned off.
Key descriptions
1 Power switch:
To turn on/off power supply
2 “CONST” key:
Select voltage or current to be constant
3 “MO E” key:
Select the volts, amps, or time to be displayed
&
“UP” & “ OWN” key:
Changes the setting value of the selected parameter.
5 “RUN” key:
To start/stop the output of power from the power supply
7

Tabla de contenidos
Otros manuales de Fuente de alimentación de Wealtec


















